    PM229 - Issue 3 (November 2008) Brunel 1A/2CB/3CB Free Standing Stove M ODELS: 7008/7008BL/7008LG/7051/7051BL/7051LG/7053/7053BL/7053LG Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland). IMPORTANT This appliance will become hot whilst in operation, it is therefore recommended that a suit ...

  • Stovax 7008 - page 2

    COVERING THE FOLLOWING MODELS: 7008/7008BL/7008LG/7051/7051BL/7051LG/7053/7053BL/7053LG 2 COMMISSIONING 22 MAINTENANCE & SERVICING 23 Annual Service 23 Removal of Log Guard 24 Removal of Fire Brick 24 Removal of Baffle 24 Removal of Riddling Mechanism 24 Fitting a New Glass Door 24 Fitting a New Door Seal 24 BASIC SPARE PARTS LIST 25 SERVICE RE ...

  • Stovax 7008 - page 3

    3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Dealer appliance was purchased from Name: ................................................................................................................................................................. Address: ..................... ...

  • Stovax 7008 - page 4

    4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance. 1.3 Only use for domestic heating in accordance with these operating instructions. 1.4 You must b ...

  • Stovax 7008 - page 5

    5 USER INSTRUCTIONS Airwash Closed Open Primary Air Open Closed Secondary Combustion Control (not 1A) Closed Open PR7225a DOOR HANDLE 1.12 Use a protective gloved hand to operate. See Diagram 4 DO NOT OPEN THE DOOR WITH BARE HANDS Door Tool: Lift and Pull forward to open WARNING Properly installed, operated and maintained this appliance will not em ...

  • Stovax 7008 - page 6

    6 USER INSTRUCTIONS 3.2 Solid fuel:  •Burn only anthracite or manufactured briquette smokeless fuels listed as suitable for use with closed heating appliances Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this will invalidate the product guarantee . 3.3 Fuel consumption . As tested at n ...

  • Stovax 7008 - page 7

    7 USER INSTRUCTIONS  •Rake the embers evenly over the fire bed and open the Airwash control fully for a few minutes before re-fuelling 5.2 Burn new logs at high output for a few minutes before adjusting the Airwash control . Refuel little and often for clean, efficient burning. 5.3 Experience establishes set ...

  • Stovax 7008 - page 8

    8 USER INSTRUCTIONS 5.11 You must burn only anthracite or smokeless fuels suitable for use in closed appliances . 5.12 Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this invalidates the product guarantee . Do not load fuel above the log guard and the secondary combustion inlets at the back of the firebox. See Diagr ...

  • Stovax 7008 - page 9

    9 7. ASH REMOVAL 7.1 All fuels:  •Open Doors, See Diagram 11 AR2142  •Riddle, See Diagram 12 Riddling Mechanism  •Remove Ashpan carefully. Heat can remain long after use, See Diagram 13 Ashpan Tool AR2140  •Use gloves, or place the ash into a Sto ...

  • Stovax 7008 - page 10

    10 13.2 The chimney, any connecting flue pipe and the appliance flue ways if incorporated, must be regularly cleaned. 13.3 Ensure adequate access to cleaning doors where it is not possible to sweep through the chimney. 13.4 If the appliance is believe to have previously served an open fire the chimney must be swept a second time within a month of r ...

  • Stovax 7008 - page 11

    11 USER INSTRUCTIONS 15. SEASONAL USE 15.1 Clean and service the appliance if it is not used during the warmer periods of the year as detailed in the Maintenance and Servicing section 15.2 Set the air controls 50% open to keep the appliance ventilated and stop the build-up of any moisture inside. 15.3 Before re-lighting the appliance: •R emove ...

  • Stovax 7008 - page 12

    12 TECHNICAL SPECIFICATION Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG Nominal Heat Output Wood kW 4.0 4.0 1.25 0.05 3.3 3.4 396 369 125 5 6.0 6.0 1.25 0.05 5.5 5.8 360 360 150 6 7.0 7.0 1.25 0.05 5.2 4.5 442 442 150 6 kW mm Wg inch Wg g/s g/s °C °C mm inch Solid Fuel All Fuels Wood Solid F ...

  • Stovax 7008 - page 13

    13 BRUNEL DIMENSIONS Description Brunel 1a Brunel 2CB Brunel 3CB Model 7008 7008BL 7008LG 7051 7051BL 7051LG 7053 7053BL 7053LG A 525 640 685 385 437 550 290 335 330 106 115 115 430 545 588 125 125 150 89 122 155 95 103 103 B C D E F (dia) G H All dimensions in mm. (25.4mm = 1”) PR7225 TECHNICAL SPECIFICATION ...

  • Stovax 7008 - page 14

    14 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks. 1.2 You must check the following: — The construction of the masonry chimneys, flue block chimn ...

  • Stovax 7008 - page 15

    15 2.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in diagram. 2.2 The building must have a suitable load-bearing capacity for the hearth and appliance.  •Consult a structural engineer for advice before proceeding 2.3 When fitting ...

  • Stovax 7008 - page 16

    16 SITE REQUIREMENTS WALLS NEXT TO HEARTHS Solid, non-combustible material e.g. masonry or concrete Thickness W C 150mm minimum 150mm minimum C H PR7227 Position of Appliance & Hearth in relation to walls Requirement for the walls Distance of hearth from wall 'C' Distance of Appliance to wall Min thickness of Wall 'W' Min he ...

  • Stovax 7008 - page 17

    17 PRE-INSTALLATION CHECKS Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG Flue/Chimney size Flue/Chimney Minimum Height* Without Liner System Round (diameter) mm 150 150 150 666 135 135 135 5 1 / 2 5 1 / 2 5 1 / 2 150 † 150 150 6 † 6 6 444 13 13 13 inch mm inch mm inch m feet Without Liner S ...

  • Stovax 7008 - page 18

    18 PRE-INSTALLATION CHECKS 3. VENTILATION 3.1 This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm 2 per kW of appliance rated output above 5kW. 3.2 Increase air supply provisions where a room contains multiple appliances. 3.3 ...

  • Stovax 7008 - page 19

    19 LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations* and standards**, along with any local regulations and working practices that may apply. Should any conflict occur between these instructions and these regulations t ...

  • Stovax 7008 - page 20

    20 INSTALLATION INSTRUCTIONS The Flue must be installed in accordance with manufacturers instructions. Seal Collar with Fire Cement Self Tapping Screw Tee Size Stovax Part No. 5" 4516 6" (4616)* Cap PR7228 PR7229 600mm min 1000mm max unsupported Elbow with access cover Size Stovax Part No. 5" 4512 6"* 4612 Flue Pipe 915mm (3ft) ...

  • Stovax 7008 - page 21

    21 INSTALLATION INSTRUCTIONS 3.3 Take care when handling, as bricks can become fragile after use. Life span depends on the type of fuels burnt and the level of use.  •Replace damaged bricks as soon as possible 3.4 To remove bricks:  •Lift Baffle and pull as far forward as possible  • ...

  • Stovax 7008 - page 22

    22 COMMISSIONING 1.1 To commission: • Replace the firebricks, baffle, and log retainer  • Check the door alignment and catch operation, adjust if required, see Installation Section 6. Adjusting Door hinges  • Check the soundness of door seals, castings and joints  •C heck the operation of the air controls 1.2 Now carry ...

  • Stovax 7008 - page 23

    23 MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Stovax or call 01392 474011 1. ANNUAL SERVICE 1.1 At the end of the heating season strip, inspect and clean the appliance as detailed:  •Allow appliance to cool  •Remove all of the following internal parts; baff ...

  • Stovax 7008 - page 24

    24 1.4 Using the appliance for the first time:  • Burn at a low output for the first day of use This allows the seals, fixing glues and paint to fully cure. 1.5 During this time the appliance may give off some unpleasant odours:  •Keep the room well ventilated to avoid a build-up of fumes. 1.6 Your Stov ...

  • Stovax 7008 - page 25

    25 BASIC SPARE PARTS LIST BRUNEL 1A BRUNEL 2CB BRUNEL 3CB BRUNEL 1A 1 2 3 4 5 6 7 8 9 10 12 13 11 Diagram No. Description Part No. 1 BafePlate BR24 2 Side Firebrick BR29 3 Glass Panel Clip BR43 4 Glass Clip screw BR46 5 Door glass GL0228 6 Door pin BR48 7 Ashpan Door Pin BR47 8 Log Retainer BR11 9 Ashpan BR5 10 Implement Tool BR22 11 Grate Ba ...

  • Stovax 7008 - page 26

    26 NOTES ...

  • Stovax 7008 - page 27

    SERVICE RECORDS 27 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:........................................................................................ Dealer's Stamp/HETAS Registration Num ...

  • Stovax 7008 - page 28

    28 ...

  • Stovax 7008 - page 29

    29 ...

  • Stovax 7008 - page 30

    Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com ...

Manufacturer Stovax Category Stove

Documents that we receive from a manufacturer of a Stovax 7008 can be divided into several groups. They are, among others:
- Stovax technical drawings
- 7008 manuals
- Stovax product data sheets
- information booklets
- or energy labels Stovax 7008
All of them are important, but the most important information from the point of view of use of the device are in the user manual Stovax 7008.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Stovax 7008, service manual, brief instructions and user manuals Stovax 7008. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Stovax 7008.

A complete manual for the device Stovax 7008, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Stovax 7008 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Stovax 7008.

A complete Stovax manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Stovax 7008 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Stovax 7008, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Stovax 7008, that we can find in the current document
3. Tips how to use the basic functions of the device Stovax 7008 - which should help us in our first steps of using Stovax 7008
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Stovax 7008
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Stovax 7008 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Stovax 7008?

Use the form below

If you did not solve your problem by using a manual Stovax 7008, ask a question using the form below. If a user had a similar problem with Stovax 7008 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)