Инструкция обслуживания Emerson CF3300ORH

16 страниц 0.35 mb
Скачать

Перейти на страницу of 16

Summary
  • Emerson CF3300ORH - page 1

    Part No. F40BP73850000 Form No. BP7385 U.L. Model No.: CF3300 READ AND SA VE THESE INSTRUCTIONS Model Numbers CF3300AP CF3300ORH ST CR OIX ™ Net Weight: 44.8 Lbs. Damp Loca tion Ceiling F an Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceilin ...

  • Emerson CF3300ORH - page 2

    2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on acci ...

  • Emerson CF3300ORH - page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. NOTE: Blades and downrod kit sold separately. a. Fan assembly b. Two fan motor covers c. One decorative downrod sleeve d. One upper decorative downrod sleeve assembly e. One decorative strap ring f. One ce ...

  • Emerson CF3300ORH - page 4

    U.L. Model No.: CF3300 Ho w to Put Y our Ceiling F an T ogether HAIRPIN CLIP CLEVIS PIN DOWNROD COUPLING DOWNROD EXTENSION 5/16-18 x 1/4" CUP POINT SETSCREW (2) Figure 1 4 OFF K. HANGER BRACKET ASSEMBL Y M. SW22 WALL CONTROL A. FAN ASSEMBL Y B. FAN MOTOR COVERS (2) H. RIGHT HAND BLADE FLANGES (4) C. DECORA TIVE DOWNROD SLEEVE ASSEMBL Y G. CEIL ...

  • Emerson CF3300ORH - page 5

    5 1/4 x 10mm ROUND HEAD SCREW (4) DOWNROD EXTENSION DOWNROD Figure 2 DOWNROD SETSCREW (3) DECORA TIVE DOWNROD SLEEVE ASSEMBL Y Figure 3 DOWNROD SETSCREW (3) DOWNROD UPPER DECORA TIVE DOWNROD SLEEVE DECORA TIVE STRAP RING Figure 4 U.L. Model No.: CF3300 5. Route the motor lead wires and support wire through the decorative downrod sleeve assembly. Ca ...

  • Emerson CF3300ORH - page 6

    6 CEILING CANOPY DOWNROD DOWNROD EXTENSION HANGER BALL PIN SETSCREW 1/4 x 10mm ROUND HEAD SCREW (4) Figure 6 10. Route the motor lead wires and support wire through the downrod extension and the hanger ball (Figure 6). 11. Securely attach the downrod to the downrod extension/hanger ball using the four 1/4 x 10mm round head screws (supplied in the d ...

  • Emerson CF3300ORH - page 7

    7 CEILING CEILING SUPPORT CABLE HANGER BRACKET OUTLET BOX CEILING JOIST WOOD MEMBER (2" x 4" Approx.) Figure 8 HANGER BALL T AB HANGER BALL/DOWNROD ASSEMBL Y A TT ACH SUPPORT WIRE TO CEILING SUPPORT WIRE Figure 9 1. Securely attach the ceiling support wire to the ceiling joist or structural member using the 3/8 x 2” hex lag bolt and fla ...

  • Emerson CF3300ORH - page 8

    8 Ho w to W ire Y our Ceiling F an If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire w ...

  • Emerson CF3300ORH - page 9

    9 Blade Installation CEILING CANOPY 1-1/4" THREADED STUD (2) #8 EXTERNAL TOOTH LOCKWASHER (2) #8-32 KNURLED KNOB (2) Figure 11 Figure 13 To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling canopy and the ceiling. WARNING U.L. Model No.: CF3300 NOTE: The r ...

  • Emerson CF3300ORH - page 10

    U.L. Model No.: CF3300 10 Final Installation 4. Attach the decorative straps to the upper ring using the flat head screw and nut (provided in the downrod kit), Figure 16. UPPER DECORA TIVE DOWNROD SLEEVE SETSCREW (4) DECORA TIVE STRAP RING CEILING CANOPY DOWNROD FAN ASSEMBL Y STRAP SLOT 1. Loose the setscrew on the upper decorative downrod sleeve a ...

  • Emerson CF3300ORH - page 11

    U.L. Model No.: CF3300 11 This control is designed to operate two ceiling fans, and not any accessory light kits. The SW22 speed control is rated for 3.0 amps at 120 volts. NOTE: Electrical connections should be in accordance with the National Electrical Codes and all Local Codes. Before starting, disconnect power to the circuit at the fuse box or ...

  • Emerson CF3300ORH - page 12

    12 U.L. Model No.: CF3300 IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. Maintenance ...

  • Emerson CF3300ORH - page 13

    13 U.L. Model No.: CF3300 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire switch wire connections in the switch hou ...

  • Emerson CF3300ORH - page 14

    14 OFF 23 3 2 3 4 5 6 7 10 22 13 14 15 21 20 18 12 19 27 DOWNROD KIT - SOLD SEP ARA TEL Y 26 25 11 8 BLADES - SOLD SEP ARA TEL Y 25 11 9 BLADES - SOLD SEP ARA TEL Y 26 31 32 29 30 28 16 17 1 25 R epair Par ts U.L. Model No.: CF3300 ...

  • Emerson CF3300ORH - page 15

    15 Key Model Numbers N o . Description CF3300AP00 CF3300ORH00 1 Hanger Bracket Assembly, 763548 763548 Consisting of: * Structural Mounting Plate — — * Hanger Bracket — — 2 Hanger Ball Assembly, 763550 763550 Consisting of: * Hanger Ball — — 3 Downrod Extension (1) 763553 763553 4 Ceiling Canopy 763552 763552-1 5 Upper Trim Ring 763554 ...

  • Emerson CF3300ORH - page 16

    Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73850000 Printed in China 02/09 Form No. BP7385 U.L. Model No.: CF3300 ...

Производитель Emerson Категория Fan

Документы, которые мы получаем от производителя устройства Emerson CF3300ORH мы можем разделить на несколько групп. Это в частности:
- технические чертежи Emerson
- инструкции обслуживания CF3300ORH
- паспорта изделия Emerson
- информационные брошюры
- энергетические этикетки Emerson CF3300ORH
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Emerson CF3300ORH.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Emerson CF3300ORH, инструкции обслуживания, короткие инструкции или инструкции пользователя Emerson CF3300ORH. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Emerson CF3300ORH.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Emerson CF3300ORH, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Emerson CF3300ORH пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Emerson CF3300ORH.

Полная инструкция обслуживания Emerson, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Emerson CF3300ORH - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Emerson CF3300ORH, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Emerson CF3300ORH, которое найдем в данном документе
3. Советы по использованию основных функций устройства Emerson CF3300ORH - которые должны облегчить нам первые шаги во время использования Emerson CF3300ORH
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Emerson CF3300ORH
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Emerson CF3300ORH в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Emerson CF3300ORH?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Emerson CF3300ORH, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Emerson CF3300ORH со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)