Инструкция обслуживания Ei Electronics Ei146RC

16 страниц Не касается
Скачать

Перейти на страницу of 16

Summary
  • Ei Electronics Ei146RC - page 1

    IDEALLY I NSTALL IN T HE C ENTRE OF CEILIN G AT L EAST 3 00mm FROM L IGHT FITTINGS LOCATE IONISATION A LARMS AWAY FROM KITCHENS TO PREVENT NUISANCE ALARM S ENSURE L IVE MAINS IS CORRECTLY CONNECTED TO L TERMINALS ON A LL INTERCONNECTED A LARMS - OTHERWIS E UNITS WILL BE DAMAGED DO N OT FIT ACTUAL A LARM UNTIL A LL BUILDING WORK IS C OMPLETED TO AVO ...

  • Ei Electronics Ei146RC - page 2

    1.1 Installation Guide 2 ...

  • Ei Electronics Ei146RC - page 3

    2. Alarm Removal SLIDE AL AR M OFF BA SE WI TH T HE S CREW DRIVER STILL IN SER TE D, PUSH TH E LO WE R HALF OF TH E ALARM AW AY F ROM THE SCRE WD RIVER, I N TH E DIRECTION OF THE ARROW ON THE COVER HOLD T HE L OW ER H ALF OF THE ALA RM AND REMOVE FRO M THE BASE PLATE B Y MO VI NG I T VERTICALL Y DO WNWA RDS, T O WA RD S T HE F L OO R REMOVE A L ARM ...

  • Ei Electronics Ei146RC - page 4

    2. HOW MANY ALARMS TO INSTALL - CATEGORIES & GRADES - The advice here follows the guidance in British Standard BS 5839-Part 6: 2004 in general (for further information see the BS standard itself). The main reason for fitting Smoke & Heat Alarms in dwellings is to ensure that when there is a fire, sufficient early warning is given so that ev ...

  • Ei Electronics Ei146RC - page 5

    for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.3m of potential ...

  • Ei Electronics Ei146RC - page 6

    for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.3m of potential ...

  • Ei Electronics Ei146RC - page 7

    for dwellings where occupants may be at high risk (e.g. elderly) OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.3m of potential ...

  • Ei Electronics Ei146RC - page 8

    2.2 Selecting Alarm Type 1 Optical Smoke Alarms are recommended due to their excellent response to smouldering fires. If there is likely to be problems with steam, contamination or dust build-up, or if there is significant risk of a fast burning clean fire an Ionisation Smoke Alarm should be fitted. 2 Ionisation and Optical Smoke Alarms should be f ...

  • Ei Electronics Ei146RC - page 9

    Improved Audibility The effectiveness of Category LD2 and LD3 systems can be significantly enhanced if an additional Smoke Alarm (interconnected) is installed in the master bedroom. This will help ensure that a responsible person will quickly be alerted to a fire and can arrange for an orderly evacuation of children and other vulnerable occupants. ...

  • Ei Electronics Ei146RC - page 10

    Wall mounting of smoke alarms (only): If ceiling mounting is impractical, smoke alarms may be mounted on a wall, provided that: a) the top of the detection element is between 150mm and 300mm below the ceiling; b) the bottom of the detection element is above the level of any door openings; Wall mounting should only be considered where close spaced b ...

  • Ei Electronics Ei146RC - page 11

    • Do not locate in insect infested areas . Small insects getting into the smoke detector chamber can cause intermittent alarms. Insects and contamination on the Heat Alarm sensor can increase its response time. 4. INSTALLATION The Alarm is designed to be permanently mounted, using it’s own built-in terminal block to connect it to the mains. The ...

  • Ei Electronics Ei146RC - page 12

    Note: BS 5839-6 2004 gives the folowing recommendations regarding the mains supply to be used in a Grade D system (The Ei141RC/146RC/161RC/166RC Smoke Alarms and Ei144RC/164RC Heat Alarms can be used in a Grade D system). The power supply for the Alarms should be derived from the public electricity supply to the dwelling. The mains supply to the Al ...

  • Ei Electronics Ei146RC - page 13

    We strongly recommend that you check for the following before connecting the alarm : • check for Live and Neutral using a two probe tester. • check for Live using a neon tester. • check that the Interconnect wire is NOT connected to Live, Neutral or Earth. Do not use an Earth wire for the Interconnect line. N.B. The alarm does not need to be ...

  • Ei Electronics Ei146RC - page 14

    prevent air draughts affecting the smoke/heat entering the alarm. If the hole is too large or the alarm does not seal it, it should be sealed with silicone rubber or equivalent. 6. Replace the wiring cover. Check the alarm battery is connected (Ei141RC/144RC/146RC only). 7. Carefully line up the unit on the base and slide on. 8. Press and hold the ...

  • Ei Electronics Ei146RC - page 15

    In the UK it is recommended that the following coloured cores are used (for example with triple flat 6243Y cable). 230V supply Brown Neutral Grey - sleeved blue at terminations Interconnect Black The interconnect wire (minimum 0.75mm 2 cable) must be treated as if it was Live. It should be insulated and sheathed. A maximum of 250 metres of wire can ...

  • Ei Electronics Ei146RC - page 16

    5. ACCESSORIES Alarm System Control Switch Ei1529RC: The Syst em Contr ol Switc h is recommended for systems with three or more Smoke / Heat Alarms. It a llo ws the user to perform the following functions from a remote location: LOCATE - If alarms sound press Locate to allow source of alarm to be identified. SILENCE - Press Hush to silence nuisance ...

Производитель Ei Electronics Категория Smoke detector

Документы, которые мы получаем от производителя устройства Ei Electronics Ei146RC мы можем разделить на несколько групп. Это в частности:
- технические чертежи Ei Electronics
- инструкции обслуживания Ei146RC
- паспорта изделия Ei Electronics
- информационные брошюры
- энергетические этикетки Ei Electronics Ei146RC
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Ei Electronics Ei146RC.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Ei Electronics Ei146RC, инструкции обслуживания, короткие инструкции или инструкции пользователя Ei Electronics Ei146RC. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Ei Electronics Ei146RC.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Ei Electronics Ei146RC, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Ei Electronics Ei146RC пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Ei Electronics Ei146RC.

Полная инструкция обслуживания Ei Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Ei Electronics Ei146RC - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Ei Electronics Ei146RC, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Ei Electronics Ei146RC, которое найдем в данном документе
3. Советы по использованию основных функций устройства Ei Electronics Ei146RC - которые должны облегчить нам первые шаги во время использования Ei Electronics Ei146RC
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Ei Electronics Ei146RC
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Ei Electronics Ei146RC в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Ei Electronics Ei146RC?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Ei Electronics Ei146RC, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Ei Electronics Ei146RC со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)