Инструкция обслуживания Napoleon BGDV42N

28 страниц 1.88 mb
Скачать

Перейти на страницу of 28

Summary
  • Napoleon BGDV42N - page 1

    1 W415-0381 / C / 05.13.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, CSA 2.33, ANSI Z21.88 FO ...

  • Napoleon BGDV42N - page 2

    2 W415-0381 / C / 05.13.04 WARNING • • • • • Do not burn wood or other ma terials in this f ir e place . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same r oom as the fire place. • ...

  • Napoleon BGDV42N - page 3

    3 W415-0381 / C / 05.13.04 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON gas fireplaces are manufactured under the strict Standard of the wo ...

  • Napoleon BGDV42N - page 4

    4 W415-0381 / C / 05.13.04 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the BG D42 to the current Na- tional Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is imp ...

  • Napoleon BGDV42N - page 5

    5 W415-0381 / C / 05.13.04 Use only Wolf S teel or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-V ent, follow the installation procedure provided ...

  • Napoleon BGDV42N - page 6

    6 W415-0381 / C / 05.13.04 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits. *** The periscope GD-401 requires a minimum 18 inches clearance fro ...

  • Napoleon BGDV42N - page 7

    7 W415-0381 / C / 05.13.04 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated. FIGURES 3 a-c FIGURE 4 TYPICAL VEN ...

  • Napoleon BGDV42N - page 8

    8 W415-0381 / C / 05.13.04 VER VER VER VER VER TICAL TICAL TICAL TICAL TICAL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION HORIZONT HORIZONT HORIZONT HORIZONT HORIZONT AL AL AL AL AL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION vertical rise vertical rise vertical rise vertical rise vertical rise is ...

  • Napoleon BGDV42N - page 9

    9 W415-0381 / C / 05.13.04 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° elbow) for the following symbols used in the v ...

  • Napoleon BGDV42N - page 10

    10 W415-0381 / C / 05.13.04 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE I ...

  • Napoleon BGDV42N - page 11

    11 W415-0381 / C / 05.13.04 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Napoleon BGDV42N - page 12

    12 W415-0381 / C / 05.13.04 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 fee t Example 4: when (H T ) > (V T ) Simple venting configurations See graph to determine the required vertical rise V T for the ...

  • Napoleon BGDV42N - page 13

    13 W415-0381 / C / 05.13.04 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napo- leon dealer . See Accesso- ries to order the specific kit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling and the roof to provide the minimum 1 inch ...

  • Napoleon BGDV42N - page 14

    14 W415-0381 / C / 05.13.04 Use only approved aluminum flexible liner kits marked: "W olf Steel Appro ved V enting" as identif ied by the stamp only on the 8” outer liner . FIGURE 18 F or safe and proper operation of the fireplace, follow the venting inst r uctions exactly . A VENT SHIELD MUST BE USED IF THE W ALL TERMINAL IS INST ALLED ...

  • Napoleon BGDV42N - page 15

    15 W415-0381 / C / 05.13.04 FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf S teel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf S teel support ring assem- bly or equivalent no ...

  • Napoleon BGDV42N - page 16

    16 W415-0381 / C / 05.13.04 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using ei- ther an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply hig ...

  • Napoleon BGDV42N - page 17

    17 W415-0381 / C / 05.13.04 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURES 31-33. It is not necessary to install a hearth extension with this fireplace system. When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness ...

  • Napoleon BGDV42N - page 18

    18 W415-0381 / C / 05.13.04 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing tab so that ...

  • Napoleon BGDV42N - page 19

    19 W415-0381 / C / 05.13.04 1. Remove the upper louvres, and open the glass door . Remove the logs. 2. Remove the securing screw al- ready in place at the back of the fire- box. If the unit is supplied with a rear log support, remove before install- ing the rear panel. Place the rear panel against the back of the firebox and re-install the rear log ...

  • Napoleon BGDV42N - page 20

    20 W415-0381 / C / 05.13.04 4. Cradle the notch on the bottom of the left crossover log (#4) around the left outermost grate post and the top into the pocket provided on the back log. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover l ...

  • Napoleon BGDV42N - page 21

    21 W415-0381 / C / 05.13.04 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in ac- cordance with local codes. In the absense of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United States If the fireplace was not previ ...

  • Napoleon BGDV42N - page 22

    22 W415-0381 / C / 05.13.04 ELECTRICAL INST ALLA TION T O BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 N A TIONAL ELECTRICAL CODE in the United S tates. T o safely install the fa ...

  • Napoleon BGDV42N - page 23

    23 W415-0381 / C / 05.13.04 • Turn off all gas to the fireplace. • Open windows. • D o not try to light any appliance. • D o not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas ...

  • Napoleon BGDV42N - page 24

    24 W415-0381 / C / 05.13.04 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjustment may be required depending on fuel type, vent configuration and altitude. ...

  • Napoleon BGDV42N - page 25

    25 W415-0381 / C / 05.13.04 # P ART NO . DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 *W680-0005 THERMOCOUPLE 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 HIGH TEMPERA TURE SEALANT 6 W455-0069 NA TURAL GAS PILOT INJECTOR 6 W455-0067 PROP ANE GAS PILOT INJECTOR 7 W725-0025 NA TURAL ...

  • Napoleon BGDV42N - page 26

    26 W415-0381 / C / 05.13.04 ...

  • Napoleon BGDV42N - page 27

    27 W415-0381 / C / 05.13.04 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace ...

  • Napoleon BGDV42N - page 28

    28 W415-0381 / C / 05.13.04 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure. - check if supply piping size is to code. Correct ...

Производитель Napoleon Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Napoleon BGDV42N мы можем разделить на несколько групп. Это в частности:
- технические чертежи Napoleon
- инструкции обслуживания BGDV42N
- паспорта изделия Napoleon
- информационные брошюры
- энергетические этикетки Napoleon BGDV42N
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Napoleon BGDV42N.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Napoleon BGDV42N, инструкции обслуживания, короткие инструкции или инструкции пользователя Napoleon BGDV42N. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Napoleon BGDV42N.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Napoleon BGDV42N, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Napoleon BGDV42N пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Napoleon BGDV42N.

Полная инструкция обслуживания Napoleon, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Napoleon BGDV42N - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Napoleon BGDV42N, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Napoleon BGDV42N, которое найдем в данном документе
3. Советы по использованию основных функций устройства Napoleon BGDV42N - которые должны облегчить нам первые шаги во время использования Napoleon BGDV42N
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Napoleon BGDV42N
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Napoleon BGDV42N в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Napoleon BGDV42N?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Napoleon BGDV42N, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Napoleon BGDV42N со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)