  • Windsor D250(115V) 10070100 - page 1

    Read these instructions bef ore operating the machine MOD EL: D250 (115V) 10070100 Beginning with Serial No. 1000054537 86038570 05/11/07 PRV NO. 98828 AB CARPET EXTRACTOR Operating Instru ctions (ENG ) ...

  • Windsor D250(115V) 10070100 - page 2

    TABLE OF CONTENTS D-250 86038570 05/11/07 1 Data Log/Table of Contents .................... 1 Safety Instructions ................................... 2 Grounding Instructions ............................ 3 Operations ............................................... 4 Maintenance …………………………. ..... 6-9 Troubleshooting ............. ...

  • Windsor D250(115V) 10070100 - page 3

    SAFETY INSTRUCTIONS D-250 86038570 05/11/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded ...

  • Windsor D250(115V) 10070100 - page 4

    GROUNDING INSTRUCTIONS NOTE: In Can ada, th e use o f a tem p orary adaptor i s no t p ermit te d by the C anadia n Electri cal Co de PROPER GR OUND ING (115V) Meta l Sc r e w A daptor Grounded Out let Box Fig. A Fig. B Fig. C Tab For Gr ounding S crew Grounded Outlet Grounding P in A dapto r THIS PRODUCT IS FOR COMMERCI AL USE ONLY. ELECTRICAL: Th ...

  • Windsor D250(115V) 10070100 - page 5

    OPERATIONS D-250 86038570 05/11/07 4 CARPET INSPECTION: Determine precisely what areas you a re going to clean. Note problem areas in the carpe t or tack strip. Look for loose carpet, heavily damaged a rea s, discolored stains, or grease spots that will require prespotting. Note the carpet type. Check the availability of hot water, drains, and suit ...

  • Windsor D250(115V) 10070100 - page 6

    OPERATION D-250 86038570 05/11/07 5 HEATER OPERATION The disconnect fittings o n the heater will become extremely hot during operation. Allow sufficient time to cool, or run solution through the machine with the heater turned off before disconn ecting the or performing any maintenance on the h eater. Before disconnecting the heater, ope n wand valv ...

  • Windsor D250(115V) 10070100 - page 7

    MAINTENANCE D-250 86038570 05/11/07 6 DAILY MAINTENANCE: (At the end of each working day): 1. Flush the entire system, including floor t ool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2. Vacuum out the solution tank . 3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospi ...

  • Windsor D250(115V) 10070100 - page 8

    MAINTENANCE D-250 86038570 05/11/07 7 SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check hose s f or wear, bloc kag es, or damage * Check handles, swit ches, and knob s for damage * Check vac motor intake filter and clea n * Run one gallon of water t ...

  • Windsor D250(115V) 10070100 - page 9

    MAINTENANCE D-250 86038570 05/11/07 8 ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplug machi ne. 2. Remove recovery tank. 3. Locate the vacuum motor wires and discon nect at the connector. 4. Remove the vacuum motor. 5. Reverse process to install vacuum moto r. ...

  • Windsor D250(115V) 10070100 - page 10

    MAINTENANCE D-250 86038570 05/11/07 9 D-250 PUMP MAINTENA NCE Per manufacturer’s recommendatio ns the following main tena nce should be performed utilizi ng noted kits: 1.) 500 hours-Kit 86201080 – PRV NO. 250 -75A replaces the V-packing, wave washer, pa cking spreader a nd plunger guide. 2.) 500 hours-Kit 86201100 – PRV NO. 250 -75C replaces ...

  • Windsor D250(115V) 10070100 - page 11

    TROUBLESHOOTING D-250 86038570 05/11/07 1 0 TROUBLE SHOOTING CHAR T PROBLEM POSSIBLE CAUSE SOLUTION No power to machine Dead electrical circuit Check building circuit breaker o r fuse box. Electrical shock Faulty power cord Replace. Equipment not grounding Follow grounding instructions exa ctly. Electrical shock Receptacle not grounded Contact an e ...

  • Windsor D250(115V) 10070100 - page 12

    TECHNICAL SPECIFICATIONS D-250 86038570 05/11/07 11 TECHNICAL SPECIFICATIONS ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250 ) 230 V, 50 Hz, 15 Amps (D250IE) ELECTRIC VACUUM MOTOR (1) –2/1.25 HP, 2 stage, Waterlift –150” (381cm) SOLUTION PUMP 250 psi, adj. SOLUTION CAPACITY 17 gallons (64.3ltr) RECOVERY CAPACITY 15 gallons (56.75ltr) ...

  • Windsor D250(115V) 10070100 - page 13

    NOTES: D-250 86038570 05/11/07 12 ...

  • Windsor D250(115V) 10070100 - page 14

    RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 13 28 13 34 35 36 13 29 35 37 30 31 32 33 ...

  • Windsor D250(115V) 10070100 - page 15

    RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 14 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86033260 05151 1 TUBE ASM, RECOVERY TANK 2 86242230 500009 1 LABEL, WARNING 3 86002620 260-64A 1 ACCESS CO VER CLEAR 6” W/RIM 4 86275800 70546 6 SCR, 8 X 3/4 PFHT/S BLK ZINC 5 86199840 090-12A 1 FLOAT CA GE ASSY COMPLETE SLIP 6 86033330 ...

  • Windsor D250(115V) 10070100 - page 16

    CONTROL PANEL GROUP D-250 86038570 05/11/07 15 5 4 6 2 18 19 3 9 1 16 11 13 17 10 8 12 14 7 15 ...

  • Windsor D250(115V) 10070100 - page 17

    CONTROL PANEL GROUP D-250 86038570 05/11/07 16 REF PART NO. PRV NO. QTY DESCRI PTION SERIAL NO. FROM NOTES: 1 86199650 070-08 1 FAN 105 CFM AXIAL 2 86090870 61367 1 PANEL ASM, CONT. 3 SW W/HEAT 3 86276290 70621006 4 SCR, #10 X 3/4 PPHST HI-LO BLK 4 86199660 070-08A 1 FAN FINGE R GUARD 5 86273810 70018 1 SCR, 1/4-20 X 1 HHCS SS 6 86256960 72142 3 SW ...

  • Windsor D250(115V) 10070100 - page 18

    VACUUM GROUP (LOWER) D-250 86038570 05/11/07 17 4 6 5 7 3 2 10 11 1 8 9 12 ...

  • Windsor D250(115V) 10070100 - page 19

    VACUUM GROUP (LOWER) D-250 86038570 05/11/07 18 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86274980 70335 1 SCR, 10-32 X 1/2 PHTR GRN/GRND 2 86256480 70813 3 STUD, 14/20 X 3.5 SS 3 86010630 87013 3 WASHER, 1/4 ID X 5/8 OD SS 4 86201970 065-92 3 VAC SPACER 2 1/4 II STAGE 5 86003760 35166 1 GASKET, VAC MTR 6 86090980 360-24A 1 PLAT ...

  • Windsor D250(115V) 10070100 - page 20

    PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 19 1 2 5 7 6 8 9 10 11 16 15 12 13 14 3 4 ...

  • Windsor D250(115V) 10070100 - page 21

    PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 20 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86199640 030-16 1 ELBOW, 1/4 NPT STREET LONG 90D 2 86200260 151-50C 1 HOSE, PULSE 47.0 1/4MPT X 1/4 MPT 3 86197370 31017 1 ELBOW, 1/4 FPT X 1/4 FPT INCLUDED IN HEATER ASSEMBLY 4 86005590 56014 1 NIPPLE, 1/4 CLOSE INCLUDED IN HE ...

  • Windsor D250(115V) 10070100 - page 22

    SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 21 10 11 13 12 14 16 8 7 6 11 25 24 5 4 27 1 26 29 28 2 3 1 11 12 23 17 18 19 15 30 35 16 36 37 12 33 34 32 36 20 22 11 12 9 20 21 39 38 40 40 ...

  • Windsor D250(115V) 10070100 - page 23

    SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 22 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86201290 280-02 2 RIVET AL. 3/16 X 1/2 CLOSED 2 86201500 260-71 1 SOLUTION COVER D/B 3 86002450 22015 1 COUPLER, 1/4 OD 4 86005590 56014 1 NIPPLE, 1/4 CLOSE 5 86199580 250-35 1 D/B BPR 200 PSI 6 86200250 151-50B 1 HOSE, 42” GRY 3/8 1/4M ...

  • Windsor D250(115V) 10070100 - page 24

    SPARE PARTS D-250 86038570 05/11/07 23 SUGGESTED SPARE PARTS PART NUMBER PRV NO. DESCRIPTION SERIAL NO. FROM 86199890 100-04A FUSE 3 AMP 200 PSI 86199240 250-33A BPR REPAIR KIT PUMPTEC 86201810 130-14I THERMOSTAT W/SPADE LEADS 86201790 130-14C THERMOSTAT RESET 86201150 250-79E PUMPTEC 300/400PSI PUMP KIT 1 86201160 250-79F PUMPTEC 300PSI PUMP KIT 2 ...

  • Windsor D250(115V) 10070100 - page 25

    115V WIRING DIAGRAM D-250 86038570 05/11/07 24 ...

Производитель Windsor Категория Vacuum Cleaner

Документы, которые мы получаем от производителя устройства Windsor D250(115V) 10070100 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Windsor
- инструкции обслуживания D250(115V) 10070100
- паспорта изделия Windsor
- информационные брошюры
- энергетические этикетки Windsor D250(115V) 10070100
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Windsor D250(115V) 10070100.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Windsor D250(115V) 10070100, инструкции обслуживания, короткие инструкции или инструкции пользователя Windsor D250(115V) 10070100. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Windsor D250(115V) 10070100.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Windsor D250(115V) 10070100, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Windsor D250(115V) 10070100 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Windsor D250(115V) 10070100.

Полная инструкция обслуживания Windsor, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Windsor D250(115V) 10070100 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Windsor D250(115V) 10070100, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Windsor D250(115V) 10070100, которое найдем в данном документе
3. Советы по использованию основных функций устройства Windsor D250(115V) 10070100 - которые должны облегчить нам первые шаги во время использования Windsor D250(115V) 10070100
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Windsor D250(115V) 10070100
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Windsor D250(115V) 10070100 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Windsor D250(115V) 10070100?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Windsor D250(115V) 10070100, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Windsor D250(115V) 10070100 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)