    Introduction Congratulations on your purchase of an advanced NAPCO EXPRESS XP-600 Security System. Meticulously developed by a leading manufacturer of state-of-the-art security products, this system will provide you with unprecedented peace-of-mind & incorporates some of the most sophisticated features available today. Above all, it has been de ...

  • NAPCO EXPRESS XP-600 - page 3

    3 1 Bell / Battery Test Test your bell or siren by pressing A followed by 1 .This will cause the bell, or siren to sound for 2 seconds and also initiate a test of the battery . 2 Central Station Communication Test (This test should only be performed on weekends or at a time designated by your alarm company) 1. Notify Central Station of the impendin ...

  • NAPCO EXPRESS XP-600 - page 4

    ARMED READY SYSTEM ü FIRE AC ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 4 Keypad Controls and Indicators Ready Light will light when all zones are secure and system is ready to be Armed. AC Light will light to indicate that AC Power is present. Fire Alarm Light will flash and the Keypad sounder will beep when system is in a Fire Alarm Condition (Se ...

  • NAPCO EXPRESS XP-600 - page 5

    Arming Your System When Leaving 1 Before arming your system, make sure the Green Ready light is ON. This indicates that all of your prot- ective zones are secure. If any zones are open, the corresponding Zone light will be ON. Secure these zones before proceeding. If any zones cannot be secured, see Bypassing Zones below. 2 Enter your user code. Th ...

  • NAPCO EXPRESS XP-600 - page 6

    Protecting Yourself While at Home 1 Before arming your system, make sure the Green Ready light is ON. This indicates that all of your protective zones are secure. If any zones are open, the corresponding Zone light will be ON. Secure those zones before proceeding. 2 Enter your user code. The Green Ready light will go out, and the Red Armed light wi ...

  • NAPCO EXPRESS XP-600 - page 7

    Emergency Buttons The three sets of emergency buttons, if programmed, are always active whether the system is armed or disarmed. Discuss these Buttons with your installer. The emergency signal will only be activated when the two respective buttons are pressed at the same time. Fire Alarm : Simultaneously press E + E to sound a fire alarm, and to al ...

  • NAPCO EXPRESS XP-600 - page 8

    Disarming Your System when Returning 1 Enter your premises through the Entry/Exit door. The keypad will sound a steady tone to remind you to disarm the system before your Entry Delay time expires. 2 Enter your user code. The Red Armed light will go out, indicating that the system has been disarmed. Note: If you make a mistake entering your code, pr ...

  • NAPCO EXPRESS XP-600 - page 9

    Preparing a Fire Escape Plan Even with the most advanced fire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your building. (space is provided on the next page) Show two exits - a front or back door and a window from each room. (Make sure each window works. You may need a special fire-escape lad ...

  • NAPCO EXPRESS XP-600 - page 10

    10 Fire Protection Floorplan Draw a plan of your premises below. Oi218a.pub page 10 Thursday, December 18, 1997 18:29 ...

  • NAPCO EXPRESS XP-600 - page 11

    Special Functions A By pressing A followed by the appropriate key, (do not press simultaneously) these special functions and features can be enabled: A0 Easy Arm (when system is disarmed) The Easy Arm feature allows the system to be armed by pressing A followed by 0 . This will allow the easy arming of the system by someone who is not a regular sys ...

  • NAPCO EXPRESS XP-600 - page 12

    The XP600 is constantly monitoring its own components, as well as all critical services, such as AC Power and the Telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble does occur, it will caution you by lighting the yellow ü ü SYSTEM light and beeping the keypad buzzer. If you ...

  • NAPCO EXPRESS XP-600 - page 13

    13 ü ü System Troubles Keypad Beeps or ü ü SYSTEM Flashes Zone light ON System Trouble Condition Action 2 Beeps 2 Fire Trouble A problem has been detected in the Fire Circuit. Call installing company for service. 2 Beeps 3 Wireless Receiver Trouble A problem has been detected with the wireless receiver. Call installing company for service. 2 Be ...

  • NAPCO EXPRESS XP-600 - page 14

    Your Installer has assigned a User 1 Code which may be used to not only Arm and Disarm the system, but also to enter the User Program Mode, where you can program other user codes. The following explains how you will use this code to program or erase additional user codes. Entering the User Program Mode Press A followed by 8 and then enter the User ...

  • NAPCO EXPRESS XP-600 - page 15

    Ambush Code - In the event that you are forced by an intruder to dis- arm your system, this special code can be used to disarm the system, and simultaneously send a silent alarm to Central Station. If your sys- tem has the Ambush feature enabled, the code assigned as the User 6 code will function as your Ambush Code Arming / Disarming - Turning the ...

  • NAPCO EXPRESS XP-600 - page 16

    NAPCO LIMITED WARRANTY THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC . This equipment generates and uses radio-frequency energy and, if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with ...

Производитель NAPCO Категория Home Security System

Документы, которые мы получаем от производителя устройства NAPCO EXPRESS XP-600 мы можем разделить на несколько групп. Это в частности:
- технические чертежи NAPCO
- инструкции обслуживания EXPRESS XP-600
- паспорта изделия NAPCO
- информационные брошюры
- энергетические этикетки NAPCO EXPRESS XP-600
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания NAPCO EXPRESS XP-600.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа NAPCO EXPRESS XP-600, инструкции обслуживания, короткие инструкции или инструкции пользователя NAPCO EXPRESS XP-600. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия NAPCO EXPRESS XP-600.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства NAPCO EXPRESS XP-600, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании NAPCO EXPRESS XP-600 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей NAPCO EXPRESS XP-600.

Полная инструкция обслуживания NAPCO, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией NAPCO EXPRESS XP-600 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания NAPCO EXPRESS XP-600, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся NAPCO EXPRESS XP-600, которое найдем в данном документе
3. Советы по использованию основных функций устройства NAPCO EXPRESS XP-600 - которые должны облегчить нам первые шаги во время использования NAPCO EXPRESS XP-600
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем NAPCO EXPRESS XP-600
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра NAPCO EXPRESS XP-600 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся NAPCO EXPRESS XP-600?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с NAPCO EXPRESS XP-600, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с NAPCO EXPRESS XP-600 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (2)

Günter

Hallo !!! Auf meinem Eingabefeld leuchtet gelbes Lämpchen vor SYSTEM und in Abständen ein piepst ,woran kann das liegen. Grüsse

Günter

Ich benötige eine Bedienungsanleitung für das Security System Napco EXPRESS Sries XP-600 in Deutsch. In Englisch habe ich sie mit dem Kauf der Immobilie erhalte, spreche aber kein Englisch.