  • Lennox International Inc. 15CHAX Series - page 1

    01/08 *2P0108* Page 1 505,201M *P505201M* RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE  2006 Lennox Industries Inc. Dallas, Texas, USA Table of Contents Shipping & Packing List 1 . . . . . . . . . . . . . . . . . . . . . . . . . Unit Dimensions 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts Arrangement 3 . . . . . . ...

  • Lennox International Inc. 15CHAX Series - page 2

    HORIZONTAL SUPPLY AIR OPENING BACK VIEW END VIEW TOP VIEW A B FRONT VIEW HORIZONTAL RETURN AIR OPENINGS (2) C L FG H J K D E E D DOWN−FLOW SUPPLY AIR OPENING DOWNFLOW RETURN AIR OPENING E D E D END VIEW CONDENSATE DRAIN ELECTRICAL INLET 2−1/2 (64) 2−1/2 (64) 2−3/4 (70) 2−3/4 (70) 2−3/4 (70) 2−1/2 (64) AA CC DD FF BB EE E D 2 (51) Page ...

  • Lennox International Inc. 15CHAX Series - page 3

    Page 3 Parts Arrangement General These installation instructions are intended as a general guide only, for use by an experienced, licensed contractor (or equivalent). The 15CHAX units are single−package electric units designed for outdoor installation o n a rooftop or a slab. The units are equipped with a transformer and blower control for applic ...

  • Lennox International Inc. 15CHAX Series - page 4

    Page 4  For installation on combustible material. WARNING Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.) Fiberglass wool may ...

  • Lennox International Inc. 15CHAX Series - page 5

    Page 5 Existing Common Vent Systems The 15CHAX packaged cooling units with auxiliary electric heat may replace an existing furnace which is being re- moved from a venting system commonly run with separate gas appliances. In this case, the existing vent system is likely to be too large to properly vent the remaining at- tached appliances. Conduct th ...

  • Lennox International Inc. 15CHAX Series - page 6

    Page 6 Filters Filters are not factory−supplied with the unit; however, optional internally installed filter kits are available. Filter kit 92 M 5 4 is used with 2, 2−1/2 and 3−ton units. Filter kit 92M55 is used with 3−1/2, 4 and 5−ton units. The filter kits accommodate the use of 1", 2" or 4" filters. If the optional filt ...

  • Lennox International Inc. 15CHAX Series - page 7

    Page 7 Unit must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code, ANSI/NFPA No. 70 (latest edition) or CSA C22.2 Part 1 (latest edition). Power supply to the unit must comply with all applicable codes and NEC or CEC. A fused disconnect switch should be field provided for the u ...

  • Lennox International Inc. 15CHAX Series - page 8

    Page 8 Figure 7 15CHAX Series Packaged Electric Units Typical Wiring Diagram ...

  • Lennox International Inc. 15CHAX Series - page 9

    Page 9 Blower Control Board (A54) Electric shock hazard. Can cause injury or death. Before attempting to perform any service or m aintenance, turn the electrical power to unit OFF at disconnect switch(es). Unit may have multiple power supplies. WARNING ! 15CHAX units are equipped with a variable speed motor that is capable of maintaining a specifie ...

  • Lennox International Inc. 15CHAX Series - page 10

    Page 10 COOL The COOL jumper is used to determine the CFM during cooling operation. This jumper selection is activated for cooling when Y1 is energized. Th e blower motor runs at 80 percent of the selected air flow fo r the first 7−1/2 minutes of each cooling demand. This fea- ture allows for greater humidity removal and saves energy. In the cool ...

  • Lennox International Inc. 15CHAX Series - page 11

    Page 11 System Operation Monitor (LSOM) The system operation monitor (A132) detects the most common fault conditions in the air conditioning system. Whe n an abnormal condition is detected, the module com- municates the specific condition through its ALERT and TRIP lights. The module is capable of detecting both me- chanical and electrical system p ...

  • Lennox International Inc. 15CHAX Series - page 12

    Page 12 Table 5 System Operation Monitor LED Troubleshooting Codes Status LED Condition Status LED Description Status LED Troubleshooting Information Green Power" LED ON Module has power 24VAC control power is present at the module terminal. Green Power" LED OFF Module not powering up Determine/verify that both R and C module termin ...

  • Lennox International Inc. 15CHAX Series - page 13

    Page 13 Unit Start−Up and Operation Each 15CHAX packaged cooling unit is factory−charged with R−410A refrigerant. The compressor is hermetically sealed, internally sprung and base−mounted with rubber−insulated hold−down bolts. Pre−Start Check List: 1 − M a ke sure refrigerant lines do not rub against the cabi- net or each other. 2 ? ...

  • Lennox International Inc. 15CHAX Series - page 14

    Page 14 Condenser Fan Clearances The top of the condenser fan should be 1−1/2 inches from the bottom of the top grille. This dimension should be checked and the fan should be adjusted accordingly any time servicing of the outdoor fan system is required. Maintenance At the start of each cooling season, this equipment should be serviced by a licens ...

Производитель Lennox International Inc. Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Lennox International Inc. 15CHAX Series мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lennox International Inc.
- инструкции обслуживания 15CHAX Series
- паспорта изделия Lennox International Inc.
- информационные брошюры
- энергетические этикетки Lennox International Inc. 15CHAX Series
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lennox International Inc. 15CHAX Series.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lennox International Inc. 15CHAX Series, инструкции обслуживания, короткие инструкции или инструкции пользователя Lennox International Inc. 15CHAX Series. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lennox International Inc. 15CHAX Series.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lennox International Inc. 15CHAX Series, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lennox International Inc. 15CHAX Series пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lennox International Inc. 15CHAX Series.

Полная инструкция обслуживания Lennox International Inc., должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lennox International Inc. 15CHAX Series - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lennox International Inc. 15CHAX Series, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lennox International Inc. 15CHAX Series, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lennox International Inc. 15CHAX Series - которые должны облегчить нам первые шаги во время использования Lennox International Inc. 15CHAX Series
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lennox International Inc. 15CHAX Series
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lennox International Inc. 15CHAX Series в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lennox International Inc. 15CHAX Series?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lennox International Inc. 15CHAX Series, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lennox International Inc. 15CHAX Series со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)