Инструкция обслуживания Oregon Scientific BAR898HGA

14 страниц 1.33 mb
Скачать

Перейти на страницу of 14

Summary
  • Oregon Scientific BAR898HGA - page 1

    1 GB INTRODUCTION Congratulations on your purchase of the BAR898HGA Long- Range Wireless Weather Station with In-Out Thermo-Hygrometer and RF Clock. This unit is an all-in-one weather forecasting device which has multiple weather-related functions. Also, with an internal antenna the reception range of this unit can be up to 100 meters. The BAR898HG ...

  • Oregon Scientific BAR898HGA - page 2

    2 GB FEA TURES : MAIN UNIT A. LCD DISPLAY A1. WEATHER FORECAST WINDOW - Graphically illustrates the weather forecast - Indicates trends in atmospheric pressure - Indicates when main unit battery is low A2. TEMPERATURE WINDOW - Displays current, minimum or maximum indoor and remote temperature - Indicates the temperature trend A3 . HUMIDITY WINDOW - ...

  • Oregon Scientific BAR898HGA - page 3

    3 GB B3. [ MEMORY ] BUTTON - Displays minimum and maximum temperature and humidity readings, and erases memory data B4. [ CHANNEL ] BUTTON - Displays the temperature and humidity readings of the indoor or remote sensor B5. [ SNOOZE / LIGHT ] BUTTON - Activates the snooze function or turn on the backlight B6 . DETACHABLE TABLE - STAND ( [ SNOOZE / L ...

  • Oregon Scientific BAR898HGA - page 4

    4 GB D 3 . [ mb / hPa - inHg ] SLIDE SWITCH - Selects between "mb / hPa" or "inHg" pressure unit display D 4. [ °C / °F ] SLIDE SWITCH - Selects between Centigrade (°C ) or Fahrenheit (°F) temperature unit display D5 . [ZONE] BUTTON Press to select among the 4 U.S. time-zones: Pacific(P), Mountain(M), Central (C) or Eastern ...

  • Oregon Scientific BAR898HGA - page 5

    5 GB NOTES ON OPERA TION For best operation: 1. Insert batteries for the main unit first. Then proceed with inserting the batteries for the remote unit. 2. Position the remote unit and the main unit within effective transmission range. In usual circumstances, the effective range is up to 100 meters or 300 feet. 3. Though the remote unit is weather ...

  • Oregon Scientific BAR898HGA - page 6

    6 GB BA TTERY AND CHANNEL INST ALLA TION: REMOTE UNIT The remote thermo-hygro sensor unit uses two (2) UM-3 or “AA” size batteries. Follow these steps to install / replace batteries: 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °C/°F sl ...

  • Oregon Scientific BAR898HGA - page 7

    7 GB Day-of-the-week Language Monday Tuesday We d. Thursday Friday Saturday Sunday English French Spanish When the unit is receiving radio signal, the RADIO RECEPTION signal will start to blink. A complete reception generally takes about 2 to 10 minutes, depending on the strength of the radio signal. When the reception is complete, the RADIO RECEPT ...

  • Oregon Scientific BAR898HGA - page 8

    8 GB HOW TO SET AND ACTIV A TE THE ALARM To set the Alarm Press [ALARM] button to display the daily alarm time (the icon " " will be displayed) Press [ALARM] and hold for three seconds, the value for the hour will flash. Press UP [ ] or DOWN [ ] buttons to make changes to the alarm hour setting. Press [ALARM] and the minute digits will fl ...

  • Oregon Scientific BAR898HGA - page 9

    9 GB search for remote sensor signals, press [MEMORY] and [CHANNEL] simultaneously. If that fails, check if the remote sensor is still in place. Make sure the transmission is within range and the path is clear of obstacles and interference. Repeat this procedure whenever you find discrepancies between the display on the main unit and the display on ...

  • Oregon Scientific BAR898HGA - page 10

    10 GB WEA THER FORECAST The unit is capable of detecting atmospheric pressure changes. Based on collected data, it can predict the weather for the forthcoming 12 to 24 hours. The effective range covers an area of 30 to 50 km or 18 to 35 milees. NOTE : 1. The accuracy of a general pressure-based weather forecast is about 70% to 75%. 2. The weather f ...

  • Oregon Scientific BAR898HGA - page 11

    11 GB Wall-Mount: Table-Stand: HOW TO W ALL MOUNT OR USE THE T ABLE ST AND (MAIN UNIT) The unit can be wall-mounted using its recessed screw holes or placed on a flat surface using the detachable table stand. Wall-Mount: Table-Stand: Gently plug in the table stand as shown: The BAR898HGA requires entry of elevation in meters not feet. To convert fe ...

  • Oregon Scientific BAR898HGA - page 12

    12 GB HOW TO RESET THE UNIT The [ RESET ] button allows you to return all settings to factory values. Accessing the slot is required only when the unit is not operating in a favorable way such as in the rare case of a malfunction. The [ RESET ] slot is located inside the battery compartment door. To use the button: 1. Open the battery compartment d ...

  • Oregon Scientific BAR898HGA - page 13

    13 GB Temperature measurement Display range : -20.0°C to +60.0°C (-4.0°F to 140.0°F) Proposed operating range : -5.0°C to +60.0°C (23.0°F to 140.0°F) Temperature resolution : 0.1°C (0.2°F) Relative Humidity measurement Measuring Range : 25 to 90%RH at 25°C (77°F) Humidity Resolution : 1% RH Barometric Pressure measurement Pressure measu ...

  • Oregon Scientific BAR898HGA - page 14

    14 GB Warning : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC : NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are desig ...

Производитель Oregon Scientific Категория Weather Radio

Документы, которые мы получаем от производителя устройства Oregon Scientific BAR898HGA мы можем разделить на несколько групп. Это в частности:
- технические чертежи Oregon Scientific
- инструкции обслуживания BAR898HGA
- паспорта изделия Oregon Scientific
- информационные брошюры
- энергетические этикетки Oregon Scientific BAR898HGA
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Oregon Scientific BAR898HGA.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Oregon Scientific BAR898HGA, инструкции обслуживания, короткие инструкции или инструкции пользователя Oregon Scientific BAR898HGA. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Oregon Scientific BAR898HGA.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Oregon Scientific BAR898HGA, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Oregon Scientific BAR898HGA пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Oregon Scientific BAR898HGA.

Полная инструкция обслуживания Oregon Scientific, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Oregon Scientific BAR898HGA - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Oregon Scientific BAR898HGA, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Oregon Scientific BAR898HGA, которое найдем в данном документе
3. Советы по использованию основных функций устройства Oregon Scientific BAR898HGA - которые должны облегчить нам первые шаги во время использования Oregon Scientific BAR898HGA
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Oregon Scientific BAR898HGA
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Oregon Scientific BAR898HGA в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Oregon Scientific BAR898HGA?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Oregon Scientific BAR898HGA, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Oregon Scientific BAR898HGA со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)