Инструкция обслуживания Linear DMC-10PS

22 страниц 1.37 mb
Скачать

Перейти на страницу of 22

Summary
  • Linear DMC-10PS - page 1

    DMC-10 Structur ed Wir e Inter com System Installation and Operation Instructions (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com PRINTER’S INSTRUCTIONS: INSTR,INSTL,DMC-10 - LINEAR P/N: 227592 A INK: BLA CK - MA TERIAL: 20 LB . MEAD BOND - SIZE: 5.500” X 8.500” - SCALE: 1-1 ...

  • Linear DMC-10PS - page 2

    T able of Contents Introduction .............................................................................................. 1 Safety Information and Cautions ............................................................. 2 Explanation of Graphic W arning Symbols ......................................... 2 General Wiring Cautions ................. ...

  • Linear DMC-10PS - page 3

    1 Intr oduction Li near’s M & S System s bran d Mode l DMC- 10 Struc tu red Wi ring In t erco m Sys t em of fe rs severa l advan ced fea tures n ever befo re availab le in a n in t erco m sys tem. It s dis tribute d hub de sign p ro vid es eas y ins talla tion an d s truc tured w iring mo untin g compa tibili ty ne cess ar y f or mo dern re s ...

  • Linear DMC-10PS - page 4

    2 Safety Information and Cautions Explanation of Graphic W arning Symbols This symbol is intended to aler t the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that ma y be of suffi cient magnitude to constitute a risk of electr ic shoc k. This symbol is intended to aler t the user to the presence of i ...

  • Linear DMC-10PS - page 5

    3 Safety Information and Cautions (Continued) Important Safety Notes PO WER SOURCE This unit should only be connected to a 110-120 V AC power source as marked on the unit. GROUNDING OR POLARIZA TION Do not defeat the saf ety purpose of the polarized or grounding-type plug. A polar ized plug has tw o blades with one wider than the other . A groundin ...

  • Linear DMC-10PS - page 6

    4 Component Featur es SIGNAL OVERLOAD SIGNAL LEVEL ADJ. MUTE OUTPUT LEFT RIGHT DMC-10AWP AUDIO INPUT POWER CONNECTOR EXPAN S ION HUB CONNECTOR EXPAN S ION HUB S TATU S INDICATOR MUTE ENABLE S WITCHE S DOOR RELEA S E ENABLE S WITCHE S DOOR RELEA S E CONNECTOR S TATION S TATU S INDICATOR S ( 8 ) S TATION CONNECTOR S ( 8 ) DMC-10P S PATIO S TATION DMC ...

  • Linear DMC-10PS - page 7

    5 Installation System Design Evaluate the installation to determine locations for mounting the intercom components. The inter com hub mounts in a new or existing structured wiring enclosur e. The DMC-10RS r oom stations can be located in any rooms that r equir e communications. DMC-10PS patio stations are weather r esistant and designed to be mount ...

  • Linear DMC-10PS - page 8

    6 Installation (Continued) Junction Box Installation Each intercom station mounts inside a standard 2-gang J-box. Mount the J-boxes fl ush with the drywall at locations and heights convenient for the installation. System Wiring Route Cat-5 or Cat-5e cable from each station’ s J-box to the structured wiring enclosure wher e the hub will be mounte ...

  • Linear DMC-10PS - page 9

    7 Installation (Continued) Hub Wiring Use a T ype 110 punch-down tool (if using an impact tool, set the tool to “low” force!) to connect the Cat-5 cable from each station to the color coded connectors on the hub. Wire the door station(s) fi rst. The hub’ s station location number determines the sound of the door station’ s chime. Hub stati ...

  • Linear DMC-10PS - page 10

    8 Installation (Continued) Optional Expansion Hub Installation T o increase the system’ s capacity , a second hub can be connected to the primary hub. The hubs connect to each other with up to 150 feet of Cat-5 cable. Each hub requir es its own power supply . Mount the second hub in the enclosure (or in another enclosur e). Connect the primary hu ...

  • Linear DMC-10PS - page 11

    9 Installation (Continued) Hub Options The intercom hub has two banks of dipswitches. One bank enables or disables each door station’ s door release button. The other bank enables or disables each door or patio station’ s privacy mute and do- not-disturb feature. Select the options appropriate for the installation. The numbers on the dipswitche ...

  • Linear DMC-10PS - page 12

    10 General Operation Intercom Featur es Each room and patio station can be used for communication with other room, patio, or door stations. Also, r oom and patio stations featur e four special constant modes for room monitoring and privacy . If the optional audio input wall plate is installed, room and patio stations can be set to play to the audio ...

  • Linear DMC-10PS - page 13

    11 General Operation (Continued) Door to Room and Door to Patio Communications When visitors arrive, they push a door station button to announce their arrival. Pressing the door station’ s button sounds a chime on all stations (unless the station is set to Do-not-disturb Mode ). Door Button T o communicate with the visitor at the door station, pr ...

  • Linear DMC-10PS - page 14

    12 General Operation (Continued) Room to Room and Room to Patio Communications A typical use for the system is to communicate between room stations throughout the installation and to patio stations. T alk Button T o communicate with other people at room or patio stations, pr ess and hold the room station’ s T ALK button while speaking. Release th ...

  • Linear DMC-10PS - page 15

    13 General Operation (Continued) Patio to Room and Patio to Patio Communications A person at the patio station can make a call to the room stations, or another patio station. For security and privacy , the patio station will not trigger hands-free r eply fr om room or other patio stations. T alk Button T o communicate with people inside, press and ...

  • Linear DMC-10PS - page 16

    14 Constant Modes Four special constant modes are available for r oom stations and patio stations. Each room and patio station can be set to one of the four modes. Constant modes remain in ef fect, even after the intercom is used for other functions. The constant modes can be used to (1) prevent monitoring from other stations; (2) pr event monitori ...

  • Linear DMC-10PS - page 17

    15 Constant Modes (Continued) Monitor Mode Monitor Mode is typically used for monitoring a baby or other sounds in a room. When a r oom or patio station is set to Monitor Mode , the station’ s microphone is always on. Set other stations to Listen Mode (see below) to hear sounds from any station(s) set to Monitor Mode . T o enter or exit Monitor M ...

  • Linear DMC-10PS - page 18

    16 T roubleshooting SYMPTOM CAUSE SOLUTION No hub status indicators lit No power to hub Check power supply input & output voltage Hub station status indicator not lit on an installed station Wiring error Check Cat-5 wiring, redo wiring if necessary Expansion hub status indicator not lit (with expansion hub installed) Wiring error or no power to ...

  • Linear DMC-10PS - page 19

    17 System Setup and Option Log ST A TION NUMBER TYPE LOCA TION DIPSWITCH OPTIONS 1 ❑ ROOM ST A TION ❑ P A TIO ST A TION ❑ DOOR ST A TION MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON 2 ❑ ROOM ST A TION ❑ P A TIO ST A TION ❑ DOOR ST A TION MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON 3 ❑ ROOM ST A TION ❑ P A TIO ST A TION ❑ DO ...

  • Linear DMC-10PS - page 20

    18 Inter com Accessories & Kits DMC-10 Intercom Kits Model DMC-10Kit Contains four room stations with white faceplates, one door station with white faceplate, one system hub and power supply Model H312KIT Contains one OpenHouse brand structured wir e enclosure and cover DMC-10 Intercom Accessories Model DMC-10A WP Contains one audio input wall ...

  • Linear DMC-10PS - page 21

    19 Limited W arranty Linear LLC warrants its M&S Systems brand products to be fr ee of defects for 2 years. The warranty period begins on either (a) the date of purchase or installation date of this pr oduct, or (b) the date of closing on a new residence in which this pr oduct was originally installed. The warranty extends to the original user ...

  • Linear DMC-10PS - page 22

    Copyright © 2007 Linear LLC 227592 A ...

Производитель Linear Категория Intercom System

Документы, которые мы получаем от производителя устройства Linear DMC-10PS мы можем разделить на несколько групп. Это в частности:
- технические чертежи Linear
- инструкции обслуживания DMC-10PS
- паспорта изделия Linear
- информационные брошюры
- энергетические этикетки Linear DMC-10PS
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Linear DMC-10PS.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Linear DMC-10PS, инструкции обслуживания, короткие инструкции или инструкции пользователя Linear DMC-10PS. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Linear DMC-10PS.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Linear DMC-10PS, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Linear DMC-10PS пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Linear DMC-10PS.

Полная инструкция обслуживания Linear, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Linear DMC-10PS - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Linear DMC-10PS, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Linear DMC-10PS, которое найдем в данном документе
3. Советы по использованию основных функций устройства Linear DMC-10PS - которые должны облегчить нам первые шаги во время использования Linear DMC-10PS
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Linear DMC-10PS
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Linear DMC-10PS в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Linear DMC-10PS?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Linear DMC-10PS, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Linear DMC-10PS со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки