    1 Blue 4” Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage or Heat Pump Installation and Operating Instructions for Model: F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMAGE. Save these instru ...

  • White Rodgers 1F95-0477 - page 2

    2 INST ALLA TION Thermostat installation and all components of the control system shall conf orm to Class II circuits per the NEC code. WA RNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic par ts: 1. The cov er , which may be either a snap-on or hinge type . 2. The base, which is remo ved b y loosening all captiv ...

  • White Rodgers 1F95-0477 - page 3

    3 Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional* 24 V olt (Com- ...

  • White Rodgers 1F95-0477 - page 4

    4 WIRING DIA GRAMS Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with T wo T ransformer s Single Stage 1 (SS1) Multi- Stage 2 (MS2) No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional ...

  • White Rodgers 1F95-0477 - page 5

    5 11 10 9 1 8 7 6 5 4 14 3 13 12 Month C hang e Filter Call For Service Save T emp H old P Date Set Set Schedul e SYSTEM FA N Y ear Run Hold Heat Mo Tu We Th Fr Sa Su System On + 2 Heat Pump A uto Sched Cool Savings Em A uto A uto Cool Off Time On Menu Se t Mo P SYSTE M Heat FA N Auto Menu Room T emperature Setting T emperature System Indicator Fa ...

  • White Rodgers 1F95-0477 - page 6

    6 INST ALLER/CONFIGURA TION MENU T o enter the Configuration Menu, SYSTEM must be set to HEA T , COOL , Em or AU T O . Press the Menu b utton f or at least 5 seconds. The display will sho w item #1 in the table belo w . Press Menu button to adv ance to the next men u item. Press or to change an item option. INST ALLER/CONFIGURA TION MENU MENU SCRE ...

  • White Rodgers 1F95-0477 - page 7

    7 INST ALLER/CONFIGURA TION MENU 1 & 2) Ke ypad Lock out – This menu selection will display “ Lk” and “OFF” (def ault, ke ypad not lock ed out). The and are used to toggle the selection between OFF and “ L” (ke ypad locked out). When the k eypad lock out selection is enabled “ L” , and the MENU b utton is pressed again, the di ...

  • White Rodgers 1F95-0477 - page 8

    8 INST ALLER/CONFIGURA TION MENU per week can be changed to P3 b y pressing the or ke ys. A selection of 0 Days f or non-programmab le will eliminate the need f or EMR, and that step in the menu will be skipped. 19 & 20) Select Automatic Schedule – With just one touch of the A UTO SCHEDULE b utton this f eature allows you to prog ram a desire ...

  • White Rodgers 1F95-0477 - page 9

    9 Set Current Time and Date 1) Press Menu and then Time button once. The displa y will show the hour only . 2) Press and hold either the or button until y ou reach the correct hour and AM/PM designation (AM begins at midnight, PM begins at noon). 3) Press TIME once again. The displa y window will sho w the minutes only . 4) Press and hold either th ...

  • White Rodgers 1F95-0477 - page 10

    10 W orksheet for Re-Pr ogramming 7 Day and 5+1+1 Da y Program Cooling Program W ake Up (P eriod 1) Leave For W ork (P eriod 2) Return Home (P eriod 3) Go T o Bed (P eriod 4) MON 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F TUE WED THU FRI S AT 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F SUN 6:00 AM 75°F 8:00 AM 83°F 5:00 ...

  • White Rodgers 1F95-0477 - page 11

    11 Symptom P ossible Cause Correction Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system. Replace fuse or reset breaker . T urn switch to ON. Replace ...

  • White Rodgers 1F95-0477 - page 12

    www .white-rodger s.com www . emersonclimate.com HOMEO WNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. ...

Производитель White Rodgers Категория Thermostat

Документы, которые мы получаем от производителя устройства White Rodgers 1F95-0477 мы можем разделить на несколько групп. Это в частности:
- технические чертежи White Rodgers
- инструкции обслуживания 1F95-0477
- паспорта изделия White Rodgers
- информационные брошюры
- энергетические этикетки White Rodgers 1F95-0477
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания White Rodgers 1F95-0477.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа White Rodgers 1F95-0477, инструкции обслуживания, короткие инструкции или инструкции пользователя White Rodgers 1F95-0477. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия White Rodgers 1F95-0477.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства White Rodgers 1F95-0477, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании White Rodgers 1F95-0477 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей White Rodgers 1F95-0477.

Полная инструкция обслуживания White Rodgers, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией White Rodgers 1F95-0477 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания White Rodgers 1F95-0477, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся White Rodgers 1F95-0477, которое найдем в данном документе
3. Советы по использованию основных функций устройства White Rodgers 1F95-0477 - которые должны облегчить нам первые шаги во время использования White Rodgers 1F95-0477
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем White Rodgers 1F95-0477
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра White Rodgers 1F95-0477 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся White Rodgers 1F95-0477?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с White Rodgers 1F95-0477, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с White Rodgers 1F95-0477 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)