    Lucent Technologies Bell Labs Innovations SPIRI T ® Communications System Model 308/616 Customer Installation Instructions 999-500-226 105772578 Issue 4 June 1989 ...

  • Lucent Technologies 308/616 - page 2

    Intellectual property related to this product and registered to AT&T Corporation has been transferred to Lucent Technologies Incorporated. Any references within this text to American Telephone and Telegraph Corporation or AT&T should be interpreted as references to Lucent Technologies Incorporated. The exception is cross references to books ...

  • Lucent Technologies 308/616 - page 3

    INTERFERENCE INFORMATION FCC REGULATIONS PERTAINING TO THIS EQUIPMENT NOTICE Federal Communications Commission (FCC) rules require that you be notified of the following: FCC (Part 15) This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in the installation, adminis ...

  • Lucent Technologies 308/616 - page 4

    TABLE OF CONTENTS Introduction 2 Overview of System 2 Step 1 Plan Your System 3 Step 2 Check Outlet Grounding 3 Step 3 Mount Controller 4 Mount Controller on Wall 4 Test the Incoming Telephone Lines 5 Connect Telephone Lines to Controller 5 Step 4 Wiring Runs 6 Business (4-pair) Wiring 7 Mount Jack Panel Boxes 8 Run Cable to All Telephone Locations ...

  • Lucent Technologies 308/616 - page 5

    Introduction This instruction manual will show you how to install your SPIRIT Communications System. Please read the instructions carefully before beginning installation. Overview of System What You Should Find in the Boxes With the Controller: controller three 7’ line cords system directory label cord labels Administration Manual Customer Instal ...

  • Lucent Technologies 308/616 - page 6

    Step 1 Plan Your System Draw a floor plan of your business, showing the location of the network interface jacks, where your local telephone lines come into the building. You will want to install your controller close to these jacks. Show on the floor plan the location of each telephone in your system. Also show the distances of the cable run from t ...

  • Lucent Technologies 308/616 - page 7

    Step 3 Mount Controller ■ Mount Controller on Wall Choose a location within five feet of the network interface jacks, where the local telephone company lines enter the building, and near an AC outlet that is not controlled by a switch. Be sure the controller is in a well-ventilated area with a temperature range of 40°F to 100°F, and free of exc ...

  • Lucent Technologies 308/616 - page 8

    ■ Test the Incoming Telephone Lines. TEST: If you have a standard telephone with a modular cord, plug it into each jack of the network interface, or incoming telephone lines. If these jacks do not work you will require service by your local telephone company. When the telephone lines were installed, the phone number should have been marked on the ...

  • Lucent Technologies 308/616 - page 9

    Step 4 Wiring Runs You may choose to wire your SPIRIT Communications System using 4-pair “business” wiring materials or 2-pair “customer convenience” wiring materials. While the materials are somewhat different, the procedure for labeling the wiring run is the same. Each “run” from the controller to a telephone set location should be nu ...

  • Lucent Technologies 308/616 - page 10

    Step 4A Business (4-pair) Wiring You may choose to wire your business with 4-pair “business” wiring to be ready for future communications systems. You will need the following materials: ❑ screwdriver (flathead) ❑ scissors ❑ drill and bits appropriate for your walls ❑ You will also need the following kits, available from your AT&T re ...

  • Lucent Technologies 308/616 - page 11

    ■ Mount Jack Panel Boxes Mount the jack panel boxes near the controller, creating a “jack field.” You will need one jack panel box for every six telephones in your system. Ideally, the jack field will be two to six inches below the controller if the controller is wall-mounted. Mounting screws for the jack panel boxes are included in the kit. ...

  • Lucent Technologies 308/616 - page 12

    ■ Run Cable To All Telephone Locations Select a cable extension kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, run a 200-foot cable, terminate it in a modular connecting block, plug in another cable, and repeat, up to a maximum of 1000 feet. Select a Cable Extension Kit with the right length of cab ...

  • Lucent Technologies 308/616 - page 13

    ■ Install Modular Connecting Blocks Install a modular connecting block at each telephone location Find the modular connecting block from the Cable Extension Kit and the cable installation tool from the Wiring Installation Kit. Choose the location for the connecting block according to the figure. Cut the cable, making sure you allow at least 4 inc ...

  • Lucent Technologies 308/616 - page 14

    Typical cable installation for one telephone location. Cable clip Identical labels Cable TELEPHONE LOCATION Modular connecting block Finish your installation by routing cables to all other telephone locations and installing modular connecting blocks for each one. Be sure to label both ends of each cable run identically. Route your other cables and ...

  • Lucent Technologies 308/616 - page 15

    Step 4B Wiring Run, Using Customer Convenience Wiring Customer convenience wiring materials are available at your local phone store. Different situations require different materials. For instance, if a telephone location is less than 25 feet from the controller, you may choose to buy a 25’ D4BU line cord and plug one end in the modular connecting ...

  • Lucent Technologies 308/616 - page 16

    Typical Installation Using Customer Convenience Wiring Sample System Directory Label Controller 10 11 12 13 700A4 PLUG Telephone Labels 630B Wall Connecting Block Wire Run Greater Than 50’ Telephone Set Modular Cord (D4BU) 25’ Max. Wire Run Less Than 50’ Telephone Set Cord (included with telephone) 625A 742B Wire Junction Box o r 725A Modular ...

  • Lucent Technologies 308/616 - page 17

    Step 5 Install Telephone Sets SPIRIT telephone sets are available in 6-Button and 24-Button models. The models are installed the same way. SPIRIT telephones are not like regular telephones and will not work if plugged directly into the Network Interface Jacks. Regular telephones will not work if they are plugged into the station jacks on your contr ...

  • Lucent Technologies 308/616 - page 18

    Step 6 Connect System To Wiring Runs Connect the controller to the wiring runs. Following the numbers on your wiring run labels, plug one end of a jumper cord into the jack panel box or wire junction (see pages 7 and 14) and the other end of the jumper cord into the appropriate station jack on the controller. Plug the controller power cord into the ...

  • Lucent Technologies 308/616 - page 19

    3. The left INTERCOM light should be lit if there is a 616 expansion unit installed correctly. If there is not an expansion unit installed, and the light does light, then there is a defect in the 308 controller. If a 616 expansion unit is present, check that the connector is properly installed (see the Expansion Unit Installation Instructions for f ...

  • Lucent Technologies 308/616 - page 20

    Troubleshooting What To Do If You Have Trouble With Your System: For SPIRIT Communications Systems purchased from AT&T, a customer “hotline” (1-800-628-2888) is available to help you if you have questions about or trouble with your system. If you need assistance from the hotline, please follow these instructions BEFORE calling the hotline n ...

Производитель Lucent Technologies Категория IP Phone

Документы, которые мы получаем от производителя устройства Lucent Technologies 308/616 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lucent Technologies
- инструкции обслуживания 308/616
- паспорта изделия Lucent Technologies
- информационные брошюры
- энергетические этикетки Lucent Technologies 308/616
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lucent Technologies 308/616.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lucent Technologies 308/616, инструкции обслуживания, короткие инструкции или инструкции пользователя Lucent Technologies 308/616. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lucent Technologies 308/616.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lucent Technologies 308/616, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lucent Technologies 308/616 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lucent Technologies 308/616.

Полная инструкция обслуживания Lucent Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lucent Technologies 308/616 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lucent Technologies 308/616, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lucent Technologies 308/616, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lucent Technologies 308/616 - которые должны облегчить нам первые шаги во время использования Lucent Technologies 308/616
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lucent Technologies 308/616
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lucent Technologies 308/616 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lucent Technologies 308/616?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lucent Technologies 308/616, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lucent Technologies 308/616 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)