Инструкция обслуживания GTO GP-SW050

37 страниц 2.06 mb
Скачать

Перейти на страницу of 37

Summary
  • GTO GP-SW050 - page 1

    OWNER’ S MANU AL GP -SW050 Residential Duty Swing G at e Operator With Inherent UPS Battery Back-up Syst em GPSW050 rev - 04/07/08 Printed in China f or GTO , inc. This product meets and exc eeds the requirements of UL 325 gat e operator safety standards . F or more information on GT O’ s full line of automatic gat e openers and access controls ...

  • GTO GP-SW050 - page 2

    The GP -SW050 automatic gate opera tors are intended for use with vehicular swing gates . The operators can be used in Class I, II, III, and IV applications. Converting Metric Units to English Equivalents When Y ou Know Multiply By T o F ind Symbol centimeters 0.3937 inches in. (or “) meters 3.2808 feet ft. (or ‘) kilograms 2.2046 pounds lb. (o ...

  • GTO GP-SW050 - page 3

    T able of C ont ents Gate Operator Class C ategories ...................................................................................... InsideCo ver MetricConv ersionChar t .......................................................................................................................... InsideCover SafetyInstruc tionsf ...

  • GTO GP-SW050 - page 4

    1 Important Safety Instructions SAFET Y INSTRUCTIONS FOR THE GPSW 0 5 0 SWING GA TE OPERA TORS IMPORT ANT SAFET Y INSTRUC TIONS for the S ystem Designer W ARNING: T o reduce the risk of injur y or death: 1. READ AND FOLL OW ALL INSTRUCTIONS. 2. This operator is intended for use only on vehicular gates. Pedestrians? ...

  • GTO GP-SW050 - page 5

    2 Important Safety Instructions IMPORT ANT SAFET Y INSTRUC TIONS F or the Installer W ARNING– T o reduce the risk of injury or death: I. Before Installation 1. READ AND FOLL OW ALL INSTRUCTIONS. 2.  V erifythisoperatorispr operforthetypeandsizeofgate ,anditsfrequencyofuse. 3.  Make sure ...

  • GTO GP-SW050 - page 6

    3 Important Safety Instructions IMPORT ANT SAFET Y INSTRUC TIONS Specic to Secondar y Means of Pr otec tion Against E ntrapmen t Asspecied by Under writersLaboratories Inc. UL325 (30A.1.1), automaticgate operatorsshall have provisions for , or be supplied with, at least one independent primar y and on ...

  • GTO GP-SW050 - page 7

    4 Important Safety Instructions Impor tant S afety Instructions fortheConsumer/EndU ser W ARNING: T o reduce the risk of injury or death: 1. READ AND FOLL OW ALL INSTRUCTIONS. 2.  Distribute and discuss copies of the IMPORT ANT SAFE TY INSTRUCTIONS  manual with all persons authorized to use your ga te ...

  • GTO GP-SW050 - page 8

    5 Important Safety Instructions Required Safety Pr ecautions for Gat es Safety Edge Safety Edge Safety Edge Photo Beams W arning Sign Pedestrian Gate V ehicle G ate Operator Photo Beams W arning Signs The warning signs (with orange panel) must be installed on both sides of the gate. 1. KEEP CLEAR! Gate may move at any time. 2. Do ...

  • GTO GP-SW050 - page 9

    6 Important Safety Instructions W arning Lab els These warning signs and labels should be found at the locations specied below. If any of them are missing, immediately contact your installer for replacements. 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gat ...

  • GTO GP-SW050 - page 10

    7 T echnical Specic a tions Motor •BrushlessDCmotor24VDC300watts •½Horsepower •Maximummotorcurrent20Amp •2500RPM •Openandclosetimefor90°openingisappro ximately15seconds Gear Reducer •AluminumCased1200:1,size40/63,compound ...

  • GTO GP-SW050 - page 11

    8 Owner ’ s Manual Owner ’s Manual GTO/PRO GP -SW050 AC Powered Swing Gate Operators WARNING Reducer /Operator Arm Gate Bracket 1/2" W asher (2) Plastic Spacer (1) 1/2" Nut (2) ½" – 2¾" Bolt (2) Clevis Pin (1) Hairpin Clip (1) Gate W arning Signs (one for each side) F ully Assembled Operator 33 in (84 cm) TO BASE 27 in ( ...

  • GTO GP-SW050 - page 12

    9 This unit must only be installed by an e xperienced technician. Pr epara tion of the Gate Before installing the GT O swing gate operator , make sure: • thegateisproperlyinstalled . • thegateisplumb ,level ,andmovesfreely . • thegatedoesnotbindordragonthegr ound. Inst ...

  • GTO GP-SW050 - page 13

    10 U sing the Moun ting T empla te The mounting templa te (see inser t) isdesignedt osimplifymountingtheoperator .Itprovidestheinstallerwith the pr oper locations for running power and accessory wiring conduits.  The template is also marked with the corr ...

  • GTO GP-SW050 - page 14

    11 Mounting T emplat e (NO T TOSCALE) 10” 2½” 3” 11” 6 3/8” 4 5/8” Drill 3/8” x 3” deep 6 places. Use 3/8” wedge type anchors. 18½“ From Hinge Centerline 7“ From Hinge Centerline Gate open position Gate closed position Hinge centerline Gate post Concrete pad 16” x 16”. Consult local building codes for depth below g ...

  • GTO GP-SW050 - page 15

    12 Remo ving the Op er a tor H ousing Beforey oucangainaccesstotheoper atorframeanditsmountingholes ,thehousingwillhavet obe remov ed from the operat or . 1.    Removethe(2)3/8” allenboltsand(2)m8washersfromtheoper atorhousing(thishardwar e ...

  • GTO GP-SW050 - page 16

    13 RED WIRE to positive (+) JUMPER WIRE (Supplied) RED WIRE to positive (+) BLACK WIRE to negative (–) JUMPER WIRE (Supplied) negative (-) to positive (+) BL ACK WIRE to negative (–) 2. Connectbatteriestooper atorasshown. Theredwirec onnectstothepositiveterminal inthecontrolbo x. Theblack ...

  • GTO GP-SW050 - page 17

    14 IMPORT ANT : Be sure the opera tor housing will not be hit by a fully open gate and that the gate column will not int er fere when housing is installed. 2 ft. square area Center point of gate hinge Closed Gate Opened Gate Round Column Housing Pivot point of operator Right Mounted Arm Center point of gate hinge Center point of ga te hinge to cent ...

  • GTO GP-SW050 - page 18

    15 Bolts and W ashers Reducer Arm Key Closed Gate Closing Gate Bracket Operator Arm Reducer Arm (approx) 5°-10° Angle Clevis Pin Hairpin Clip Output Shaft Fig . 1 Fig . 2 Fig . 5 Fig . 6 Fig . 4 CAUTION: DO NOT ST AND IN THIS AREA Fig . 3 1 2 3 4 ON OPTIONS MODE 1 MODE 2 OPEN DIR. SL V OPN DUAL MODE LOW BA TT ON ON >>> SIMUL SLAVE SECURE ...

  • GTO GP-SW050 - page 19

    16 C ontr ol Board Description 1 2 3 4 ON L OCK COM COM COM ALARM CYCLE SAFETY SHADOW OPEN CL OSE STOP OPEN EDGE CL OSE EDGE ST A TUS ST ALL FORCE ADJUST LIMIT ADJUSTMENTS DUAL LINK GTO L OOP DETECTORS LIMIT SENSORS DIAG. PORT BLDC SPEED CONTROL EXIT SHADOW SAFETY A T OPEN LIMIT PRISON MODE RUNNING OPTIONS TEST SWITCHES CL OSE STOP OPEN GTO Inc. T ...

  • GTO GP-SW050 - page 20

    17 COM COM COM OPEN CL OSE STOP CL OSE EDGE LIMIT ADJUSTMENTS TEST SWITCHES CL OSE STOP OPEN GTO Inc. T allahassee, FL SX4000 Logic Board Rev . E MIN MAX MIN MAX OFF 120 <<< JOG >>> SET LIMIT W1 CUT TO USE 3 BUTTON STA TION CYCLE SAFETY OPEN EDGE RUN 2 OPEN CLOSE STOP COM COM COM ST ALL FORCE ADJUST LIMIT ADJUSTMENTS TEST SWITCHES ...

  • GTO GP-SW050 - page 21

    18 Stall F orc e and A uto - Close A djustmen ts Stall Force Adjustment: IMPORT ANT: F or sa fety reasons, the ST ALL FORCE potentiometers are set at the “10 o ’ clock” position at the factory . The obstruction sensitivity is independently adjustable for each direction of trav el. Upon sensing an obstruction,thegatewillstopand? ...

  • GTO GP-SW050 - page 22

    19 1 2 3 4 ON L OCK ALARM CYCLE SAFETY SHADOW OPEN EDGE ST A TUS ST ALL FORCE ADJUST DUAL LINK GTO L OOP DETECTORS LIMIT SENSORS DIAG. POR T BLDC SPEED CONTROL EXIT SHADOW SAFETY A T OPEN LIMIT PRISON MODE RUNNING OPTIONS <<< >>> CL OSED LED11 LED10 LED09 + ACC. PWR. 12VDC - 300ma AUTO CL OSE TIMER MODE 1 MODE 2 OPEN DIR. SL V OPN ...

  • GTO GP-SW050 - page 23

    20 1 CY CLE: ( T ypicallyforusewithdoorbellbuttonorhardwir edkeypad)  • Eachac tivationatthisinputwillcycletheoperationasf ollows:   ….→OPEN→STOP→CL OSE→ST OP→OPEN→… 2 SAFETY : ( T ypicallyforusewithphoto? ...

  • GTO GP-SW050 - page 24

    21 1 2 3 4 ON L OCK COM COM COM ALARM CYCLE SAFETY SHADOW OPEN CL OSE STOP OPEN EDGE CL OSE EDGE ST A TUS ST ALL FORCE ADJUST LIMIT ADJUSTMENTS DUAL LINK GTO L OOP DETECTORS LIMIT SENSORS DIAG. PORT BLDC SPEED CONTROL EXIT SHADOW SAFETY A T OPEN LIMIT PRISON MODE RUNNING OPTIONS TEST SWITCHES CLOSE STOP OPEN GTO Inc. T allahassee, FL SX4000 Logic B ...

  • GTO GP-SW050 - page 25

    22 Output C onnec tions Note: • Maximumratingforallr elayoutputsare24V ac/dc,1Amp .  • Allrelayoutputsaredrycontact(novoltage)switching.  • AlloutputshavecorrespondingLEDindic atorfordiagnosticpurposes. The corresponding LED indicator will be lit when it ...

  • GTO GP-SW050 - page 26

    23 A c cessor y P o w er Supply C onnec tion • 12V dc@300mA(.3A)maximumpow ersupplyforadditionalaccessories . • Ifyoulosepowert oyouraccessories,theac cessoriesareprot ectedbyapoly-fuse.Disconnect    accessoriesandallowpoly-fuset ocool ...

  • GTO GP-SW050 - page 27

    24 Pr ison Mode O per a tion ( CLASS IV APPLIC A TIONS) Prison mode operation means tha t constant pressur e at the CL OSE or the OPEN push button station input is required t o move the gate in the desir ed direction. F ollow these steps to toggle the PRISON MODE oper ation on/o : 1.  P owerdowntheunit. 2. Pr ess and hold the OPEN an ...

  • GTO GP-SW050 - page 28

    25 Reinstalling the Opera tor H ousing Check to makesur ethe safetyedges, photoelectric beams, warningsig ns, and pedestriangate (ifnecessary)are installed (see pages 5-6) befor e fastening the housing to the operator . Theinstallationiscomplet e. T esttheoperator ,accessories, ...

  • GTO GP-SW050 - page 29

    26 • Thesetwo(2)terminalspro videcommunicationconnectionsfordualgateapplica tionswhereone  unit operates as a master and the other as sla ve operat or . • Shieldedtwistedpairmustbeused. Theshield(drainwire)connectionshouldbeconnectedat   Master ...

  • GTO GP-SW050 - page 30

    27 Setting D ual Gate Sequenc e GP-SW050 operators come from the factor y with the #2 DIP switches set to OFF .  DIP Switches must be changed to accommoda te dual gate opera tion. The information below shows the proper settings for a dual gat e application. 1 2 3 4 ON L OCK COM COM COM ALARM CYCLE SAFETY ...

  • GTO GP-SW050 - page 31

    28 Safety Edges W arning Sign W arning Sign Safety Edge Safety Edge Master Operator Sla ve Operator Use Rigid Conduit for inbound A C. Use Rigid Conduit for inbound A C. Use PVC Conduit for Receiver Safety Edge Safety Edge Dual Gate Inter face Run Belden Wire® ONL Y in its own conduit, 22 A WG , 1-pair shielded with GROUND. Operator Operator Opera ...

  • GTO GP-SW050 - page 32

    29 Maint enanc e Maintenance Schedule: • T esttheoperator ,accessories,andsafetydevices monthly . •Ser vicethegateopera tor ,accessories,andsafetydevices r egularly . Maintenanc e Checklist • T estthesafetyedgestomakesurethegater esponds. •Che ...

  • GTO GP-SW050 - page 33

    30 T roubleS hooting G uide W ARNING: AL W A YS TURN OPERA T OR OFF AND DISC ONNECT BA TTERIES BEFORE ADJUSTING OR SERVICING IT . SY MPT OM DIA GNOSIS CHECK One beep every 5 seconds whenthegateisinmotion. ThereisnoA Cpowerpr esent. Thebatteryvoltageislow . • GFI • CircuitBr eaker • Connect ...

  • GTO GP-SW050 - page 34

    31 SY MPT OM DIA GNOSIS CHECK C ycle LED ON brightly Status Light ashes Cy cle terminal shor ted to C om • Pushbuttonorkeyonkeypadis stuck. • Wir ebetweenpushbutton, keypad, etc . and c ycle t erminal is shor ted • Checkterminalvoltagewith respect to Com to ensur e you read 12 vdc . Safety LED O ...

  • GTO GP-SW050 - page 35

    32 SY MPT OM DIA GNOSIS CHECK Close Edge LED ON brightly Status Light ashes CloseEdgeterminalshortedto Com • Edgesensorissensingan obstruction. • Relayfromedgesensoris shor ted or lat ched. • Wir ebetweenedgesensorand open edge terminal is shorted. • Checkterminalvoltage? ...

  • GTO GP-SW050 - page 36

    33 W arr anty and Repair Ser vice GT O A C P ow ered Gat e Operator Limit ed W arranty GTO A C powered gate operators are warranted by the manuf acturer against defects in materials and manufacturer w orkmanship for a specific period of time beginning from the date of purchase, pro vided recommended installation procedures have been follo wed. The ...

  • GTO GP-SW050 - page 37

    Installa tion Checklist The installation of this oper ator conf orms to CLASS __________. Theinstallerveriesthat(eachit emmustbechecked): ____ Requiredsafetyedgesorphotobeamsw ereinstalled. ____ Customerwasinf ormedthatthisgateisf orvehicularuse ONL Y . Pedestrians MA Y NOT ...

Производитель GTO Категория Safety Gate

Документы, которые мы получаем от производителя устройства GTO GP-SW050 мы можем разделить на несколько групп. Это в частности:
- технические чертежи GTO
- инструкции обслуживания GP-SW050
- паспорта изделия GTO
- информационные брошюры
- энергетические этикетки GTO GP-SW050
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания GTO GP-SW050.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа GTO GP-SW050, инструкции обслуживания, короткие инструкции или инструкции пользователя GTO GP-SW050. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия GTO GP-SW050.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства GTO GP-SW050, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании GTO GP-SW050 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей GTO GP-SW050.

Полная инструкция обслуживания GTO, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией GTO GP-SW050 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания GTO GP-SW050, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся GTO GP-SW050, которое найдем в данном документе
3. Советы по использованию основных функций устройства GTO GP-SW050 - которые должны облегчить нам первые шаги во время использования GTO GP-SW050
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем GTO GP-SW050
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра GTO GP-SW050 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся GTO GP-SW050?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с GTO GP-SW050, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с GTO GP-SW050 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)