Инструкция обслуживания Bryant 393AAV

12 страниц 0.12 mb
Скачать

Перейти на страницу of 12

Summary
  • Bryant 393AAV - page 1

    NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION ..........................................................................2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PRO- CEDURE ..................................... ...

  • Bryant 393AAV - page 2

    CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. INTRODUCTION These instructions are written for the Gas-Fired Induced Combus- tion Furnace. ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE CAUTION: Electrostatic discharge can affect electronic components. Take pre ...

  • Bryant 393AAV - page 3

    b. Remove filter cabinet door. c. Slide filter out of cabinet. d. If equipped with permanent, washable filter, clean filter by spraying cold tap water through filter in opposite direction of airflow. Rinse filter and let dry. Oiling or coating of the filter is not recommended. e. If equipped with factory-specified disposable media filter, replace o ...

  • Bryant 393AAV - page 4

    WARNING: Blower access door switch opens 115-v power to control center. No component operation can occur. Caution must be taken when manually closing this switch for service purposes. Failure to follow this warn- ing could result in electrical shock, personal injury, or death. NOTE: If thermostat terminals are jumpered before blower ac- cess door s ...

  • Bryant 393AAV - page 5

    (5.) Repeat foregoing procedures until each cell in furnace has been cleaned. (6.) Using vacuum cleaner, remove residue from each cell. (7.) Using vacuum cleaner with soft brush attachment, clean burner assembly. (8.) Reinstall cell inlet plates and burner assembly. Care must be exercised to center burners in cell openings. 10. Clean flame sensor w ...

  • Bryant 393AAV - page 6

    The 24-v circuit contains an automotive-type, 3-amp fuse located on the control. (See Fig. 6.) Any shorts of the 24-v wiring during installation, service, or maintenance will cause this fuse to blow. If fuse replacement is required, use ONLY a 3-amp fuse. The control LED will display status code 24 when fuse needs to be replaced. With power to the ...

  • Bryant 393AAV - page 7

    Fig. 7—Unit Wiring Diagram A00304 PCB BLOWER OFF DELAY SELECTION CHART 90 SEC 135 SEC 180 SEC 225 SEC GVR H I/L O RELA Y SEC-1 SEC-2 PL1 3 2 1 6 5 4 9 87 LED TEST/TWIN BLOWER OFF DELAY G R Y W C HUM HSI R I DR BL WR BLOWER SPEED SELECT FU1 COO L HEA T L2 PL3 PL2 VA C 120 L1 PR1 1 2 1 2 3 PR2 24 VAC -3A FUS E SP ARE-2 SP ARE-1 EAC-1 EAC-2 C 1. 5 A ...

  • Bryant 393AAV - page 8

    Fig. 8—Service Label A99233 SER VICE G R Y W Com HUM TEST LED LED CODE ST A TUS 24V 11 12 13 14 21 22 23 24 31 33 34 * 9 8 6 5 32 1 4 7 COMPONENT TEST NO PREVIOUS CODE - Stored status codes are erased when pow er (115V AC or 24V AC) to control is interrupted or 48 hours after each f ault is cleared. BLO WER ON AFTER PO WER UP (115V A C or 24 V A ...

  • Bryant 393AAV - page 9

    4. If furnace is operating properly and LED indicates proper operation, replace control access door. 5. Component Test can also be initiated by performing the following: a. Remove control access door. b. Remove blower access door. c. Manually close blower access door switch. WARNING: Blower access door switch opens 115-v power to control. No compon ...

  • Bryant 393AAV - page 10

    Troubleshooting Guide A99123a Is circuit breaker closed? Close door switch and go to start. Is red LED status light on? Is door switch closed? Is red LED status light blinking rapidly without a pause? Is there 1 15v going to switch? Replace door switch. Replace control center . Replace transformer . Is red LED status light blinking ON/OFF slowly wi ...

  • Bryant 393AAV - page 11

    A99123b 11 NO PREVIOUS F A UL T - Faults are erased after 48 hrs or whenever power (1 15v or 24v) is interrupted. Run system through a heating or cooling cycle to check system. 12 BLO WER ON AFTER PO WER UP (115V OR 24V) - Normal operation. Blower will run for 90 sec when furnace power is interrupted during a call for heat, R-W closed. 13 LIMIT OR ...

  • Bryant 393AAV - page 12

    A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based f ...

Производитель Bryant Категория Furnace

Документы, которые мы получаем от производителя устройства Bryant 393AAV мы можем разделить на несколько групп. Это в частности:
- технические чертежи Bryant
- инструкции обслуживания 393AAV
- паспорта изделия Bryant
- информационные брошюры
- энергетические этикетки Bryant 393AAV
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Bryant 393AAV.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Bryant 393AAV, инструкции обслуживания, короткие инструкции или инструкции пользователя Bryant 393AAV. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Bryant 393AAV.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Bryant 393AAV, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Bryant 393AAV пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Bryant 393AAV.

Полная инструкция обслуживания Bryant, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Bryant 393AAV - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Bryant 393AAV, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Bryant 393AAV, которое найдем в данном документе
3. Советы по использованию основных функций устройства Bryant 393AAV - которые должны облегчить нам первые шаги во время использования Bryant 393AAV
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Bryant 393AAV
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Bryant 393AAV в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Bryant 393AAV?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Bryant 393AAV, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Bryant 393AAV со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)