    Technical Su pport: 201- 934-5111 Main: 201- 934-9944 t ech @d ataprobe. com Web si t e: da t apr obe . com General Description The K3 Series A/B Switching system provide up to 3 AB switches in a 1.75 in rack mount chassis for 19” Equipment cabinets. Each switch allows a common circ uit (COM) to be switched to either of two circuits, designated A ...

  • JVC K3-R - page 2

    K3 System Page 2 Inst allation & Operation K3 Chassis The K3 Chassis holds the Power, Control and A/B Switch modules for the K3 system. It installs in a standard 19” EIA equipment cabinet, requiring 1.75” (1U) of rack height. K3 systems are preconfigured and tested in the factory. All Control, Power and Switch modules are pre-installed. Man ...

  • JVC K3-R - page 3

    K3 System Page 3 Power Supply 1930077 Converts 110/ 220 /240 VAC to 24VDC Single Slot Redundant Capable Input Power Nominal : 120/240 VAC 50/60 Hz Range : 100 - 240 VAC Watts: 50 Fusing: 2 A Environmental Operating: 0 C - +65C Physical AC Input connector: IEC 320 (C14) on rear panel Alarm / Expansion connector : 9 pin d-Sub Contact Ratings: 1A @ 24 ...

  • JVC K3-R - page 4

    K3 1RU AB Switch Page 4 Alarm Connector Alarm Connection on each power supply provides status information on the condition of the supply. 9 Pin Dsubminiature Pin 6 NO Pin 6 shorts to Pin 7 when the Power Supply is Non-Operational Pin 7 COM Pin 8 NC Pin 8 shorts to Pin 7 when the Power Supply is Operational Power Access Panel 1930079 Provides for co ...

  • JVC K3-R - page 5

    K3 1RU AB Switch Page 5 Control Modules The K3 Series AB Switch System is available with three types of control modules; Network, Contact Closure, or Gang Control Expansion. One of three control options shown below will be installed in the chassis for remote control of the installed AB switch cards. C-AB-16-R C-AB-16-R provides remote control throu ...

  • JVC K3-R - page 6

    K3 1RU AB Switch Page 6 Serial Port The Serial Port on the control card is a 9 pin male connector, configured as a DTE. The following pins are used. The following chart illustrates the pin out of the D9 connector and the connection required to an external modem with a D25 pinout. D9 Pin Abbreviation Full Name Modem D25 Pin Pin 2 RD Receive Data Pin ...

  • JVC K3-R - page 7

    K3 1RU AB Switch Page 7 Setting the IP address using ARP To set the IP address using ARP, connect the jack marked 10Base-T to your local Ethernet network and apply power to the unit. The computer used to set the IP address must be on the same physical network as the C-AB-16-R . ARP does not work across switched or routed networks. Windows (98 and L ...

  • JVC K3-R - page 8

    K3 1RU AB Switch Page 8 This password is case sensitive and can be changed in the setup process. In telnet, the The C-AB-16-R has a security timeout feature. After 2 minutes of no activity, The C-AB-16-R will automatically terminate the session. Should this occur, simply re-connect and re-enter the password. K-16 Set Location 1. New York 1 A 2. New ...

  • JVC K3-R - page 9

    K3 1RU AB Switch Page 9 Select 6 for IP Settings. The IP Settings Menu appears: IP Settings 1. IP Address 192.168.1.42 2. Subnet 255.255.255.0 3. Gateway 0.0.0.0 4. Web Port 80 5. Telnet Port 23 6. Message Port 9100 7. MTU 1024 8. Write Community Name private 9. Read Community Name public A. SNMP Manager 1 192.168.1.97 B. SNMP Manager 2 0.0.0.0 C. ...

  • JVC K3-R - page 10

    K3 1RU AB Switch Page 10 Com Port: Set the Baud Rate and Character Format for the serial port. Baud rate choices are 9600, 19200, and 38400. Character format choices are 8N1, 7E1 and 7O1 (databits, parity, stop bit). The Default Serial Port Parameters are 9600, 8 Data Bits, No Parity, One Stop Bit (9600,8,N,1) Escape Response: This selects Yes or N ...

  • JVC K3-R - page 11

    K3 1RU AB Switch Page 11 Note: After changing the IP Address, Web Port, Telnet Port or Com Port parameters, it is necessary to reboot the C-AB-16-R . By removing power to the the K3 chassis momentarily and then reconnecting the power source. Neither operation will alter the sw itch positions of any A/B Card in the Nest. MTU : Maximum Transmission U ...

  • JVC K3-R - page 12

    K3 1RU AB Switch Page 12 The web page shows the current status of each enabled card in the chassis. It also displays the status of the two power supplies in the lower right corner. To operate one or more switch cards: Select the desired A/B Card(s) using the checkbox next to the card and then click on the large A or B button under Switch Control. T ...

  • JVC K3-R - page 13

    K3 1RU AB Switch Page 13 If cards are not installed in the system, their status will be reported as Position A. To avoid confusion, use the Disable feature in the Telnet Setup for unused card slots. When cards are disabled, their name will continue to appear on the web page or telnet screen, however, their status will be indicated as displayed in t ...

  • JVC K3-R - page 14

    K3 1RU AB Switch Page 14 A logout button is provided. Click this button to be instantly logged out. There is an automatic logout function if there is no activity for two minutes. You can also just close the browser; however you will not be able to log back in for two minutes. Telnet and Serial Port The menu system of the C-AB-16-R is the same for T ...

  • JVC K3-R - page 15

    K3 1RU AB Switch Page 15 SNMP M anager Control The C-AB-16-R allows for management via SNMP. T he private MIB is available from the Dataprobe Web Site at: http://www.dataprobe.com/files/switch/k16/k16.mib MIB Outline and MIB Definitions can be found in Appendix A. Command Line and Direct TCP Messaging The C-AB-16-R can be controlled via command lin ...

  • JVC K3-R - page 16

    K3 1RU AB Switch Page 16 cr = The ASCII carriage return character If the queried card has been disabled then no response will be transmited. In response to the Query All command, 16 response messages will be sent. All invalid commands will be ignored. No response even when responses are enabled. Gang Control Expansion G-AB-1R R Gang Expansion Card ...

  • JVC K3-R - page 17

    K3 1RU AB Switch Page 17 SW 'D COM FG ISO 1 A 1 B 1 COM Show n In Facto ry De fault: Gro u nd Swi tche d & Iso l at ed A/B Switch Modules The K3 Rack Mount AB Switching System can be factory configured with up to 3 AB switches of any of the following interfaces plus one control interface and power supply configuration. Some switch interfac ...

  • JVC K3-R - page 18

    K3 1RU AB Switch Page 18 S pecifications Switch Interfaces D25 Three 25 Pin D Subminiature, Female Connectors. 25 leads switched. Option for Pins 1 and 7 common and unswitched. RJ8 Three 8 position 8 wire RJ type Modular jacks, Rear Panel/Card Edge. All 8 leads switched. Support all RJ Configurations up to 16 Mhz. NET: Three 8 position 8 wire RJ ty ...

  • JVC K3-R - page 19

    K3 1RU AB Switch Page 19 MIB Outine NOTE: The K3 Series AB Switch System use the same network control interface as our larger K16 Series. The same SNMP MIB interface is used with same values and commands .Only the 1 st three AB card slot positions of the 16 displayed are used in the K3. Display ed Slots 4 thru 16 are non functional. Mib Tree iso (1 ...

  • JVC K3-R - page 20

    K3 1RU AB Switch Page 20 MIB Definitions k16RackName 1.3.6. 1.4.1.1418.1.1.1 This read/write variable is the name of the k16 nest. This variable can be programmed either via SNMP, Telnet or via serial port. It can contain printable characters and MUST not exceed 20 characters in length. k16CardTable 1.3.6. 1.4.1.1418.1.1.2 This variable is not dire ...

  • JVC K3-R - page 21

    K3 1RU AB Switch Page 21 k16PowerSupply1 1.3. 6.1.4.1.1418.1.1.4 This read only variable returns the current status of the power supply 1 as an enumerated integer where: 1 = ok 2 = failed. k16PowerSupply2 1.3. 6.1.4.1.1418.1.1.5 This read only variable returns the current status of the power supply 2 as an enumerated integer where: 1 = ok 2 = faile ...

  • JVC K3-R - page 22

    K16 Series Standalone/ -R1 Mount Page 22 TECHNICAL SUPPORT , RETURNS and W ARRANTY Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this product. To obtain Technical Support call our Tech Support Hotline at 201- 967-8788 , or Email us at tech@dataprobe.com . Please have the following in ...

Производитель JVC Категория Switch

Документы, которые мы получаем от производителя устройства JVC K3-R мы можем разделить на несколько групп. Это в частности:
- технические чертежи JVC
- инструкции обслуживания K3-R
- паспорта изделия JVC
- информационные брошюры
- энергетические этикетки JVC K3-R
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания JVC K3-R.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа JVC K3-R, инструкции обслуживания, короткие инструкции или инструкции пользователя JVC K3-R. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия JVC K3-R.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства JVC K3-R, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании JVC K3-R пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей JVC K3-R.

Полная инструкция обслуживания JVC, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией JVC K3-R - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания JVC K3-R, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся JVC K3-R, которое найдем в данном документе
3. Советы по использованию основных функций устройства JVC K3-R - которые должны облегчить нам первые шаги во время использования JVC K3-R
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем JVC K3-R
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра JVC K3-R в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся JVC K3-R?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с JVC K3-R, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с JVC K3-R со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)