Инструкция обслуживания Oregon Scientific BPW129

13 страниц 0.92 mb
Скачать

Перейти на страницу of 13

Summary
  • Oregon Scientific BPW129 - page 1

    1 EN Oregon Scientific™ Wrist Blood Pressure Monitor (BPW129) User Manual T ABLE OF CONTENTS Introduction ................................................................... 2 Key features .................................................................. 2 Main unit ................................................................... 2 Plastic st ...

  • Oregon Scientific BPW129 - page 2

    2 EN INTRODUCTION Thank you for selecting the Oregon Scientific™ Wrist Blood Pressure Monitor (BPW129) as your health product of choice. This product has been designed to provide you with many years of reliable service provided it is used correctly , and can help you measure and track the following metrics: · Systolic pressure · Diastolic press ...

  • Oregon Scientific BPW129 - page 3

    3 EN SAFETY AND CARE INSTRUCTIONS Safety precautions Please observe the following safety precautions when setting up and using your blood pressure monitor . · This device is intended for adult use only . · This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is not intended for use on extremities other ...

  • Oregon Scientific BPW129 - page 4

    4 EN Caring for your blood pressure monitor T o ensure you receive the maximum benefit from using this product, please observe the following care guidelines. · When not in use, store the main unit in the protective plastic container that came with it. · Do not immerse the main unit in water . If it comes in contact with water , dry it immediately ...

  • Oregon Scientific BPW129 - page 5

    5 EN hypertensive people do not realize they are at risk until their health is seriously threatened. What is the standard blood pressure classification? The following chart (Figure 3) was taken from the World Health Organization (WHO), and describes the various classifications. Please note: · Hypotension value is for reference only . · Blood pres ...

  • Oregon Scientific BPW129 - page 6

    6 EN detect your blood pressure. Before every measurement, the main unit establishes a “ zero pressure ” equivalent to the air pressure. Then it starts inflating the wrist cuf f to 180mmHg or higher until it senses that it has blocked your blood in the artery . After that, the deflation process starts, during which time the main unit detects pr ...

  • Oregon Scientific BPW129 - page 7

    7 EN Positioning the wrist cuff It is important to properly position the wrist cuff to ensure that you receive an accurate reading. 1. Remove all accessories (watch, bracelet, etc.) from your left wrist. If your physician has diagnosed you with poor circulatio n in your left arm, use your right wrist. 2. Roll or push up your sleeve to expose the sk ...

  • Oregon Scientific BPW129 - page 8

    8 EN T AKING A BLOOD PRESSURE MEASUREMENT Y ou can choose to take your blood pressure while sitting or lying down. Helpful Tips for taking a measurement: · Be sure to set the clock before taking your first measurement, or whenever you replace the batteries, so that the date and time are stored in the memory with your history . For instructions, re ...

  • Oregon Scientific BPW129 - page 9

    9 EN RECALLING MEASUREMENTS STORED IN THE MEMOR Y The memory can hold up to 8 records. The records are automatically stored each time you take a new measurement. Note: · The most recent record (1) is shown first. Each new measurement is assigned to the first (1) record. All other records are pushed back one digit (e.g., 2 becomes 3, and so on), an ...

  • Oregon Scientific BPW129 - page 10

    10 EN Display is dim or will not light up. No power Batteries are exhausted. Replace with new batteries ( 6). Batteries are inserted incorrectly . Insert the batteries correctly( 6). Low batteries shows on the display . Batteries are low . Replace with new batteries ( 6). Error message shows on the display . A measurement error occurred. Relax for ...

  • Oregon Scientific BPW129 - page 11

    11 EN SPECIFICA TIONS Application: Measuring method Oscillometric / non-invasive Application For adult use only Measurement location Wrist section of lower arm Memory Maximum 8 records Dimensions: Height x Width x Depth ~ 72mm x 72mm x 24.5mm (2.8in x 2.8in x 1.0in) Weight 130g (4.6 oz) without batteries Cuff circumference ~ 13.5 – 19.5cm (5.3 ? ...

  • Oregon Scientific BPW129 - page 12

    12 EN Operating environment: Operation 10 ° C … 40 ° C (50 ° F … 104 ° F) Storage / T ransport -20 ° C … 60 ° C (-4 ° F … 140 ° F) Humidity range 10% … 83% relative humidity INFORMA TION CONCERNING THE CE MARK This device complies with the European regulations based on the Medical Products Code, and bears the CE mark “CE0123 ” ...

  • Oregon Scientific BPW129 - page 13

    13 EN kPa mmHg 60 80 100 120 140 160 180 200 220 M D D M s s Name: Age: Weight: (kg/lbs) Date Time 10 PM 10 PM 10 Oct 17 Oct SYS DIS MAP 158 90 110 155 95 112 85 90 8.0 10.7 13.3 16.0 18.7 21.3 24.0 26.7 29.3 © 2004 Oregon Scientific. All rights reserved. ...

Производитель Oregon Scientific Категория Blood Pressure Monitor

Документы, которые мы получаем от производителя устройства Oregon Scientific BPW129 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Oregon Scientific
- инструкции обслуживания BPW129
- паспорта изделия Oregon Scientific
- информационные брошюры
- энергетические этикетки Oregon Scientific BPW129
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Oregon Scientific BPW129.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Oregon Scientific BPW129, инструкции обслуживания, короткие инструкции или инструкции пользователя Oregon Scientific BPW129. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Oregon Scientific BPW129.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Oregon Scientific BPW129, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Oregon Scientific BPW129 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Oregon Scientific BPW129.

Полная инструкция обслуживания Oregon Scientific, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Oregon Scientific BPW129 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Oregon Scientific BPW129, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Oregon Scientific BPW129, которое найдем в данном документе
3. Советы по использованию основных функций устройства Oregon Scientific BPW129 - которые должны облегчить нам первые шаги во время использования Oregon Scientific BPW129
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Oregon Scientific BPW129
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Oregon Scientific BPW129 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Oregon Scientific BPW129?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Oregon Scientific BPW129, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Oregon Scientific BPW129 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)