    AIRLESS P AINT SPRA Y MACHINE 99702 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2 ...

  • Chicago Electric 99702 - page 2

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 2 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Chicago Electric 99702 - page 3

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 3 plugs with grounded power tools. Unmodied plugs and matching out - lets will reduce risk of electric shock. Do not expose power tools to rain b. or wet conditions. Water entering a power tool will increase the risk of electric shock. Do not abuse the cord. Never use c. the cor ...

  • Chicago Electric 99702 - page 4

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 4 ries, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool ac - cidentally . Store idle power tools out of the d. reach of children and do not allow persons unfamiliar with the power tool or these instructions to oper- ate the power t ...

  • Chicago Electric 99702 - page 5

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 5   grounded. Ground Fault Circuit Inter- rupter (GFCI) should also be imple- mented – it prevents sustained elec- trical shock. W ARNING: The brass components 1 1. of this produ ...

  • Chicago Electric 99702 - page 6

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 6 Use tools with the lowest vibration 4. when there is a choice between dif- ferent processes. Include vibration-free periods each 5. day of work. Grip tool as lightly as possible (while 6. ? ...

  • Chicago Electric 99702 - page 7

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 7 Double Insulated T ools: T ools with T wo Prong Plugs T ools marked “Double Insulated” do 1. not require grounding. They have a special double insulation system   and complies w ...

  • Chicago Electric 99702 - page 8

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 8 RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 14 ...

  • Chicago Electric 99702 - page 9

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 9 SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz / 7.5 A Motor 3/4 HP Operating PSI 2350 – 2650 psi Paint Flow 0.33 GPM Fuse Class F , F10A/250 V Hose Size 1/4” Oil Requirement Hydraulic Oil UNP ACKING When unpacking, make sure that the item is intact and undamaged. If ...

  • Chicago Electric 99702 - page 10

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 10 Remove plastic cap and thread the 4. pressure hose onto the hose spray port and secure. Hose connected to spray port Power Switch 5. Remove the plastic cap on the end of the spray gun and thread the other end of the hose onto it. Remove the plastic cap from gun tip. Gun connecte ...

  • Chicago Electric 99702 - page 11

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 1 1 W ork Piece and W ork Area Set Up Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction. Route the power cord along a safe 2. route to reach the work area without creating a tripping hazard ...

  • Chicago Electric 99702 - page 12

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 12 Allow the unit to draw paint until all air 10. and impurities are cleansed from the system and the paint runs pure. T urn the power Switch to its “OFF” 1 1. position and secure the return tube in its normal operating position. Purge and prime the Hose: Do not attach the Spra ...

  • Chicago Electric 99702 - page 13

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 13 Adjust the pressure control dial until 23. a solid coat of paint of desired thick- ness is achieved. Painting T ips: 24. Spray 10 to 12 inches from the  surface. Begin moving the Gun before  squeezing the T rigger . Release the T rigger before ending  the strok ...

  • Chicago Electric 99702 - page 14

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 14 MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool to its “OFF” position and unplug the tool from its e ...

  • Chicago Electric 99702 - page 15

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 15   T urn the power switch Off and un- o. plug the Sprayer . Remove the Gun from the hose. p. ? ...

  • Chicago Electric 99702 - page 16

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 16 T roubleshooting Problem Possible Causes Likely Solutions Sprayer will not start No power at outlet. 1. Cord not connected. 2. Sprayer turned off under 3. pressure. Check power at outlet. 1. Check that cord is plugged in. 2. T urn pressure control knob to maximum, or 3. PRIME/SP ...

  • Chicago Electric 99702 - page 17

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 17 PUMP P ARTS LIST Part Description Qty 1 Housing 1 2 Rocker 1 3 Inlet V alve Assembly 1 4 Retaining Ring 1 5 Pin 1 6 W asher 1 7 Screw 1 8 Nut 1 8.1 Bush 1 9 W asher 1 10 T op Seal 1 10.1 T op Seal Spring 1 11 Nut 1 12 Ball 1 13 Priming Plunger 1 14 Circle Ring 1 15 Priming Sprin ...

  • Chicago Electric 99702 - page 18

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 18 PUMP DIAGRAM ...

  • Chicago Electric 99702 - page 19

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 19 PUMP DIAGRAM, CONTINUED ...

  • Chicago Electric 99702 - page 20

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 20 SUCTION TUBE ASSEMBL Y P ARTS LIST & DIAGRAM Part Description Qty 1B Hose Nut 1 2B Circlip 1 3B Connection 1 4B T ube 1 5B  1 6B Filter 1 7B Clamp 2 8B Return T ube 1 Note:  ? ...

  • Chicago Electric 99702 - page 21

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 21 GUN P ARTS LIST & DIAGRAM Part Description Qty 1C Housing 2 2C Elbow 1 3C Pin 1 4C Seal 1 5C W asher 1 6C W asher 1 7C Ball 1 8C Spring 1 9C Pipe 1 10C Filter Housing 1 1 1C Ring 2 12C Bush 1 13C Spring 1 14C T ip 1 15C Cap 1 16C T rigger 1 GUN P ARTS LIST & DIAGRAM Part ...

  • Chicago Electric 99702 - page 22

    SKU 99702 For technical questions, please call 1-800-444-3353. Page 22 Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants ...

Производитель Chicago Electric Категория Paint Sprayer

Документы, которые мы получаем от производителя устройства Chicago Electric 99702 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Chicago Electric
- инструкции обслуживания 99702
- паспорта изделия Chicago Electric
- информационные брошюры
- энергетические этикетки Chicago Electric 99702
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Chicago Electric 99702.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Chicago Electric 99702, инструкции обслуживания, короткие инструкции или инструкции пользователя Chicago Electric 99702. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Chicago Electric 99702.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Chicago Electric 99702, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Chicago Electric 99702 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Chicago Electric 99702.

Полная инструкция обслуживания Chicago Electric, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Chicago Electric 99702 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Chicago Electric 99702, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Chicago Electric 99702, которое найдем в данном документе
3. Советы по использованию основных функций устройства Chicago Electric 99702 - которые должны облегчить нам первые шаги во время использования Chicago Electric 99702
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Chicago Electric 99702
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Chicago Electric 99702 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Chicago Electric 99702?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Chicago Electric 99702, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Chicago Electric 99702 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)