Инструкция обслуживания Omega Engineering CN8240

31 страниц 0.28 mb
Скачать

Перейти на страницу of 31

Summary
  • Omega Engineering CN8240 - page 1

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s www .omega.com e-mail: info@omega.com ome ga. com ® ® CN8240 & CN8260 SERIES Communications & Options Guide User ’ s Guide TM 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 1 ...

  • Omega Engineering CN8240 - page 2

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s i It is t he p olic y of OME GA to com ply with al l wo rldw ide safe ty a nd E MC/E MI r egu lati ons that app ly . OME GA is cons tant ly p ursui ng cer tifi cati on of its prod ucts to the Euro pean New App roac h Dir ectiv es. OME GA wi ll a dd t he C E ma rk t o ev ery ap ...

  • Omega Engineering CN8240 - page 3

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s ii T able of Contents For inf or mation and instructions related to basic operations , refer to the CN8240/CN8260 operator’ s manual supplied with your controller . Option Wiring Diagrams Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering CN8240 - page 4

    1 2 3 1 1 12 13 2 3 2 4 RCV B(-) XMT A(+) SIG GND SIG GND RS 232 RS 485 RCV XMT SIG GND CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 1 Option -C2: RS-232 (one-to-one) Communications Option Description: Provides a one-to-one connection between the controller and an RS-232 port. Computers, PLCs, or dumb terminals may be us ...

  • Omega Engineering CN8240 - page 5

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 2 RS-485 Communications 1 2 3 1 1 12 13 14 2 3 2 4 4 RCV B(-) XMT A(+) SIG GND SIG GND RS 232 RS 485 Option Description: Provides one-to-many communications. T erminate the controller furthest from the computer by either connecting a 120-ohm, 1/4-watt resistor between ter- min ...

  • Omega Engineering CN8240 - page 6

    Option Description: Remote setpoints use either voltage or current inputs, depending on the specified option: Option -DIC: Switch Input Closed Option -RSP4: 0-5 Vdc Option -RSP5: 1-5 Vdc Option -RSP6: 0-20 mA Option -RSP7: 4-20 mA The input signal is scalable in the Remote Analog Setpoint Menu. Activation of the analog setpoint causes the F1 indica ...

  • Omega Engineering CN8240 - page 7

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 4 CN8240/CN8260 Series Controllers with Digital Communications Option ome ga.c om ® ® 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 7 ...

  • Omega Engineering CN8240 - page 8

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 5 Di git al Co mmu nic at ion s O pti on This method allows bidirectional data transfer via a three-conductor cable consisting of signal ground, receive input and transmit output. It is recommended for communication distances less than 50 feet between the computer termi- nal a ...

  • Omega Engineering CN8240 - page 9

    Message Code Value = Decimal Value 00 0 + 0 = 00 99 90 + 9 = 99 A0 100 + 0 = 100 A2 100 + 2 = 102 B8 110 + 8 = 118 P5 250 + 5 = 255 CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 6 Omega+ Protocol The Omega+ Protocol provides an easy way to query and modify controller parameters using a personal computer and the optional d ...

  • Omega Engineering CN8240 - page 10

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 7 TYPE character Message T ype R Read Request or Read Response Returning a Positive Result r Read Response Returning a Negative Result W Write Positive Value Request and Response w Write Negative Value Request and Response A Auxiliary Command Di git al Co mmu nic at ion s O pt ...

  • Omega Engineering CN8240 - page 11

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 8 Di git al Co mmu nic at ion s O pti on Numeric Value ASCII Representation 3 3.0000 000003 003.00 100 100.00 0100.0 000100 3.2 003.20 0003.2 Examples of valid numeric representations f or a 6 character data field: Numeric Value Bad ASCII Representation Why? 3 BBBBB3 Leading b ...

  • Omega Engineering CN8240 - page 12

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 9 READ RESPONSE FROM CONTROLLER READ COMMAND TO CONTROLLER Controller ID Read Command Checksum Start of Message Zone Number Parameter Number End of Message $0101R01B7<CR> Controller ID Read Command Data Checksum Start of Message Zone Number Parameter Number End of Messag ...

  • Omega Engineering CN8240 - page 13

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 10 WRITE RESPONSE FROM CONTROLLER Controller ID Write Command No Error Checksum Start of Message Zone Number Parameter Number End of Message %0101W090H8<CR> A UX IL I AR Y R ES P O NS E F R O M CO N T RO LL E R A UX IL I AR Y C O M MA N D T O C O N TR O L L ER Controller ...

  • Omega Engineering CN8240 - page 14

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 11 Di git al Co mmu nic at ion s O pti on The Read Request: The Read Request is used to query parameter values and it has the following message format: [ST ART CHAR][ID][ZONE][TYPE][PARAM][CHKSUM][END CHAR] Field Description: TYPE Must contain the uppercase letter ‘R’. Req ...

  • Omega Engineering CN8240 - page 15

    Request Message Description $Ø1Ø1WØ91Ø.123G7<CR> Change both the RAM and EEPROM copies of Setpoint #1 in controller #1 to the value of 10.123 $Ø1Ø1w1Ø1Ø.123J1<CR> Change only the RAM copy of setpoint #1 in controller #1 to the value of -10.123 (notice the lowercase ‘w’). END CHAR CHKSUM DA TA P ARAM TYPE ZONE ID ST ART CHAR ...

  • Omega Engineering CN8240 - page 16

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 13 Request Message Description $Ø1Ø1AØ1XXXXXXXXXXL2<CR> T ell controller #1 to load all parameters with their defaults. The 10 X’ s are padding characters. $Ø2Ø1AØ2ØØØ1.ØØØØØ69<CR> T ell controller #2 to perform a low RTD calibration. END CHAR CHKSU ...

  • Omega Engineering CN8240 - page 17

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 14 Request Message Description %Ø1Ø1RØ5Ø21.123K8<CR> The value of the Process Variable is 21.123 Degrees C. %Ø2Ø1R1Ø1G7<CR> A serial transmission has occurred: Framing Error %Ø1Ø1rØ9Ø21.ØØØN8<CR> The value of the EEPROM setpoint #1 is -21 Degree ...

  • Omega Engineering CN8240 - page 18

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 15 Request Message Description %Ø1Ø1AØ1ØXXXXXXXXXXØ4<CR> Default load all parameters has started. %Ø2Ø1AØ2ØØ.ØØØØØØØØB6<CR> RTD low calibration on controller #2 has started. END CHAR CHKSUM DA TA ST ATUS P ARAM TYPE ZONE ID ST ART CHAR Di git al C ...

  • Omega Engineering CN8240 - page 19

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 16 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 5 Process Value X 0 6 Operating Mode X X 1 - Manual 2 - Standby 3 - Normal (automatic) 4 - Initiate Autotune 5 - Recipe Run 6 - Recipe Hold 7 Access Level X X 1 - Lockout 2 - ...

  • Omega Engineering CN8240 - page 20

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 17 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 39 Autotune Damping X X 1 - Low 2 - Normal 3 - High 40 Recipe Option X X 0 - Disabled X X 1 - Single Step X X 2 - Multi-Step 41 Single-Setpoint X X Ramp Time 42-49 Ramp Times ...

  • Omega Engineering CN8240 - page 21

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 18 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 92 Input T ype X X 0 - B Thermocouple 1 - C Thermocouple 2 - E Thermocouple 3 - J Thermocouple 4 - K Thermocouple 5 - N Thermocouple 6 - NNM Thermocouple 7 - R Thermocouple 8 ...

  • Omega Engineering CN8240 - page 22

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 19 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value A2 Output 1 Cycle Time X X A3 Output 1 Low Limit X X A4 Output 1 High Limit X X A5 Output 2 T ype X X 1 - Inactive/Disabled 2 - PID 4 - On/Off A6 Output 2 Action X X 1 - Direc ...

  • Omega Engineering CN8240 - page 23

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 20 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value D0 Alarm 2 Delay X X D1 Alarm 2 Inhibit X X D2 Alarm 2 Process Setpoint X X D3 Alarm 2 Deviation Setpoint X X D4 Communications Protocol X 0 1 - Omega + D5 Communications ID X ...

  • Omega Engineering CN8240 - page 24

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 21 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value F6 High-Voltage Span Calibration X X F7 Current Zero Calibration X X F8 Current Span Calibration X X G1 Auxiliary Output Variable X X G2 Auxiliary Output Scale Low X X G3 Auxi ...

  • Omega Engineering CN8240 - page 25

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 22 Auxiliary Commands: Command: Load Parameter Defaults Parameter #: 01 Description Restore all menu parameters to their default values. Request Data Field: Ignored. Response Data Field: Ignored. Command: Perform Process Low Calibration Parameter #: 02 Description: Performs a ...

  • Omega Engineering CN8240 - page 26

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 23 Request Data Fields: A 10-character ASCII representation of a numeric value specifying what to calibrate. 0 - Thermocouple 1 - RTD, Resistive Thermal Device 2 - Linear 3 - RAS, Remote Analog Setpoint Response Data Field: Ignored. Command: Perform Process High Calibration Pa ...

  • Omega Engineering CN8240 - page 27

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 24 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 27 ...

  • Omega Engineering CN8240 - page 28

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 25 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 28 ...

  • Omega Engineering CN8240 - page 29

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 26 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 29 ...

  • Omega Engineering CN8240 - page 30

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1 . Purc hase Order number under which the product was PURCHA SED, 2. Model an d se ria l n umb er o f t he pro duc t un der war ranty , and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REP AIRS, consult OME GA ...

  • Omega Engineering CN8240 - page 31

    W h e r e D o I F i nd E v e ry t h i n g I Ne e d f o r P r o c e s s Me a s u r e m e nt a n d C o nt r o l ? O ME G A … O f C ou r s e ! 900M124U00B TEMPERA TURE – Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies – W ire: Thermocouple, R TD & Thermistor – Calibrators & Ice Point References – Recor ...

Производитель Omega Engineering Категория Clock Radio

Документы, которые мы получаем от производителя устройства Omega Engineering CN8240 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Omega Engineering
- инструкции обслуживания CN8240
- паспорта изделия Omega Engineering
- информационные брошюры
- энергетические этикетки Omega Engineering CN8240
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Omega Engineering CN8240.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Omega Engineering CN8240, инструкции обслуживания, короткие инструкции или инструкции пользователя Omega Engineering CN8240. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Omega Engineering CN8240.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Omega Engineering CN8240, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Omega Engineering CN8240 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Omega Engineering CN8240.

Полная инструкция обслуживания Omega Engineering, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Omega Engineering CN8240 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Omega Engineering CN8240, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Omega Engineering CN8240, которое найдем в данном документе
3. Советы по использованию основных функций устройства Omega Engineering CN8240 - которые должны облегчить нам первые шаги во время использования Omega Engineering CN8240
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Omega Engineering CN8240
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Omega Engineering CN8240 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Omega Engineering CN8240?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Omega Engineering CN8240, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Omega Engineering CN8240 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)