    REFRIGERADOR POR ABSORBCIÓN p ara CAR V ANAS o MOT ORCARA V ANA S INSTRUCCIONES DE USO INSTRUCCIONES DE INST ALACI Ó N RM 6270 (L) RM 6271 (L) RM 6290 (L) RM 6291 (L) RM 6360 (L) RM 6361 (L) RM 6400 (L) RM 6401 (L) RM 7270 (L) RM 7290 (L) RM 7360 (L) RM 7400 (L) T yp C40 / 1 10 821 2690-63 T .B. 06/2003 Esp añol ES EN English MANUAL ABSORPTION R ...

  • Dometic RM 7360(L) - page 2

    2 Guarde cuidadosamente est as instrucciones de uso. En caso de transmisión del aparato adjunte estas instrucciones de uso. © Dometic GmbH - 2003 - Salvo modificación - Imprimido en Alemania Dansk Deut sch ÅëëçíéêÜ English Esp añol Français It aliano Nederlands Norsk Português Suomi Svensk via INTERNET www .dometic.com Kundeservice Ku ...

  • Dometic RM 7360(L) - page 3

    3 1.0 INTRODUCTION 4 2.0 FOR YOUR SAFETY 4 2.1 W arning and safety notices 4 2.2 Coolant 4 3.0 W ARRANTY AND CUST OMER 5 SER VICE 3.1 Damage in transit 5 4.0 DESCRIPTION OF MODEL 5 5.0 REFRIGERA T OR GUIDE 5 5.1 Cleaning 5 5.2 Using the refrigerator 6 5.3 Defrosting 9 5.4 Storing food 9 5.5 Making ice cubes 9 5.6 Door locking 10 5.7 Switching off t ...

  • Dometic RM 7360(L) - page 4

    4 INTRODUCTION Y ou have made an excellent choice in selecting the Dometic Absorption Refrigerator . W e are sure that you will be fully satisfied with your new appliance in all respects. The appliance, which works silently , meets high quality standards and guarantees the ef ficient utilisation of resources and energy throughout its entire life cy ...

  • Dometic RM 7360(L) - page 5

    5 W ARRANTY AND CUST OMER SER VICE W arranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned. For warranty or other servi cing, please contact our Dometic Service department. Any damage due to impro- per use is not covered by the warranty . The warranty does not cover any mo ...

  • Dometic RM 7360(L) - page 6

    6 Using the refrigerator  The cooling unit is silent in operation.  When the appliance is first put into operation, there may be a mild odour which will disappear after a few hours. Ensure the living area is well ventilated.  The freezer compartment should be cold about one hour after switching on the refrigerator .  The refrigerator wi ...

  • Dometic RM 7360(L) - page 7

    7 Electrical operation 1. 12V DC The refrigerator should only be used while the motor is running. 1. Set energy selector switch (A) to. The refrigerator operates without thermostatic control (continuous operation). 2. Mains power This option should only be selected where the supply voltage of the connection for power supply corresponds to the value ...

  • Dometic RM 7360(L) - page 8

    8 5. Keep rotary switch (B) depressed for another 10-15 seconds, then release. 6. Check the inspection glass to see whether a flame is burning. 7. Repeat the entire process if the flame has gone out. 8. Use rotary switch (B) to regulate the temperature in the main refrigerator compartment. 2. Automatic ignition 4. Keep rotary switch "B" d ...

  • Dometic RM 7360(L) - page 9

    9 Defrosting As time goes by , frost builds up on the fins. When the layer of frost is about 3mm thick, the refrigerator should be defrosted. 1. Switch of f the refrigerator , as described in Section 5.3 - "Switching of f". 2. Remove the ice cube tray and food. 3. Leave the refrigerator door open. 4. After defrosting (freezer compartment ...

  • Dometic RM 7360(L) - page 10

    Door locking 10 1. Loosen the front and back securing brackets. 2. Move the storage rack to the left and remove it. Dismantling: 2. 1. T o fit the storage rack, the reverse order applies. 1. Set energy selector switch (A) to position "0" (OFF). The appliance is now fully switched off. 2. Secure the door open by means of the door stop. The ...

  • Dometic RM 7360(L) - page 11

    11 W inter operation 1. Check that the ventilation grilles and the extractor have not been blocked by sno w , leaves or similar . Interior light (when fitted) Changing the light bulbs 5.9 5.10 1. Remove cover . 2. Detach defective light bulb. 3. Fit new light bulb. 4. Clip the cover back in place. 90° 1. 2. Note: for 12V DC : 1 light bulb 8V , 2W ...

  • Dometic RM 7360(L) - page 12

    12 Changing the decor p anel Dimensions of the panels in mm: Model Height Wid th Thickness RM 6270/71 713+/-1 453,5+1 3,2 RM 6360/61 713+/-1 453,5+1 3,2 RM 6290/91 718+/-1 491,5+1 3,2 RM 6400/01 718+/-1 491,5+1 3,2 RM 7270 713+/-1 453,5+1 3,2 RM 7360 713+/-1 453,5+1 3,2 RM 7290 718+/-1 491,5+1 3,2 RM 7400 718+/-1 491,5+1 3,2 5.1 1 1. Open the door ...

  • Dometic RM 7360(L) - page 13

    13 Changing the doorhang 5.12 1. Open the door , unscrew the hinge screw and keep it to hand. 2. T ake off the door by moving it upwards. 9. Attach the door . 10. Screw the hinge screw back in. 3. 4. 8. 4. 5. 5. 6. 7. It is not always possible to change the door when the refrigerator is installed. (example RM 6xx1 ) ...

  • Dometic RM 7360(L) - page 14

    14 T roubleshooting 5.13 Failure : The refrigerator does not work in gas operation mode. Possible cause Action you can take a.) Gas bottle empty . b.) Is the supply cut-out device open? c.) Air in the gas pipe? Before calling the authorised Service Department, please check whether: 1. The instructions in the section "Using the refrigerator&quo ...

  • Dometic RM 7360(L) - page 15

    15 Maintenance  Works on gas component s and electical inst allation may only be carried out by authorised personnel. We recommend to contact your Dometic Service Centre.  EN 1949 stipulates that the appliance´s gas equipment and it s associated fume system must be inspected after installation and a certificate issued. Afterwards a qualif ...

  • Dometic RM 7360(L) - page 16

    16 T echnical dat a We reserve the right to make technical changes. *Average consumption measured at an average ambient temperature of 25°C in pursuance of ISO St andard. Declaration of conformity 5.19 5.20 RM 6270 821x486x541 77 lit. 9,5 lit. 125W / 120W approx. 2,5KWh / 270g 26kg X X RM 6271 821x486x541 77 lit. 9,5 lit. 125W / 120W approx. 2,5KW ...

  • Dometic RM 7360(L) - page 17

    17 INST ALLA T I O N G U I D E On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the refrigerator must be installed as described in these instructions. In some OEM applica- tions it may not be possible for these instructions to be follo ...

  • Dometic RM 7360(L) - page 18

    18 Draught-free inst allation The refrigerator must be sealed in accordance with EN 1949 . Illustrated below are two typical approved methods of sealing. Proposal 1: Using the Inst allation Sealing Kit from Dometic (SP .No. 241 2559-00, available from Dometic) Insert lipped seals (A) into the installation recesses at the bottom and at each side. In ...

  • Dometic RM 7360(L) - page 19

    19 In this case, for gas operation, do not use the upper winter cover! If even with draught-free installation a fume chimney is desirable, you must incorporte the L100 ventilation and extraction system into the upper air vent opening. Installation of fume chimney: please refer to point 6.7. V entilation and extraction A correct installation is impo ...

  • Dometic RM 7360(L) - page 20

    20 Inst alling the ventilation system 6.4 3. Insert the ventilation grilles. 6. Insert winter cover 2. Insert the frame ... 4. Lock the ventilation grilles.. 5.Clip the extractor insert in position (only for upper ventilation system L100) ... and screw into position. 1. Seal the mounting frame, making it waterproof. Item 1 does not apply for instal ...

  • Dometic RM 7360(L) - page 21

    21 Inst allation recess The refrigerator must be installed draught-free in a recess. The measurements of the recess are given in the table below . S tep (A) is only required for cabinets with a step. Push the appliance far enough into the recess until the front edge of the refrigerator casing is flush with the front of the recess. Allow a gap of 15 ...

  • Dometic RM 7360(L) - page 22

    22 Fume extraction Fume extraction must be arranged in such a way as to provide complete extraction of all products of combustion to an area out side the living area. The flue system must slope in an upward direction in order to avoid a build-up of condensation. Fitting the fume flue in the upper ventilation grille 1. Connect T -piece (E) to adapto ...

  • Dometic RM 7360(L) - page 23

    23 Sep arate fume extraction 1. Cut an 80mm x 40mm rectangle in the outer wall of the caravan. The position of the cut must be appropriate to the particular model of refrigerator an d installation conditions. 2. Connect T -piece (E) to adaptor (F) or flue pipe (K) as required and affix with screw (G). Ensure that heat distributor (H) is lodged in t ...

  • Dometic RM 7360(L) - page 24

    24   The gas connection to the appliance is effected by means of a suit able coupling tube fitting L8, DIN 2353-ST , complying with European St andard EN 1949 (e.g. Ermeto). The gas connection may only be carried out by a qualified personnel. Following proper installation, a testing for leakage and a flame test must be carried out by *qualifi ...

  • Dometic RM 7360(L) - page 25

    25 Electrical inst allation Electrical inst allation may only be carried out by qualified personnel. The connection cables must be laid in such a way that they do not come in cont act with hot component s of the unit/burner or with sharp edges. The electrical installation must comply with national regulations (EN 60335-2-24 for Europe). It is advis ...

  • Dometic RM 7360(L) - page 26

    26 Wiring diagrams 1. Wiring diagram with manual ignition and no interior light. 2. Wiring diagram with manual ignition and interior light battery connection 12V/24V -- mains connection ~ heating- element DC- resistor (replaced by a bridge for 24V battery voltage) thermo cut-off current light DC -- reed contacts (sensor switching) to casing to ca s ...

  • Dometic RM 7360(L) - page 27

    27 3. Wiring diagram with automatic ignition and no interior light 4. Wiring diagram with automatic ignition and interior light spark plug light DC -- re e d c o n ta c ts (s e n s o r s w itc h in g ) * resistor (replaced by a bridge for 24V battery voltage) ignition control lamp thermo cut-off current mains connection ~ to casing heating- element ...

  • Dometic RM 7360(L) - page 28

    Dometic GmbH In der S teinwiese 16 D-57074 Siegen w w w .dometic.de/caravan w w w .dometic.com ...

Производитель Dometic Категория Refrigerator

Документы, которые мы получаем от производителя устройства Dometic RM 7360(L) мы можем разделить на несколько групп. Это в частности:
- технические чертежи Dometic
- инструкции обслуживания RM 7360(L)
- паспорта изделия Dometic
- информационные брошюры
- энергетические этикетки Dometic RM 7360(L)
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Dometic RM 7360(L).

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Dometic RM 7360(L), инструкции обслуживания, короткие инструкции или инструкции пользователя Dometic RM 7360(L). В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Dometic RM 7360(L).

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Dometic RM 7360(L), как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Dometic RM 7360(L) пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Dometic RM 7360(L).

Полная инструкция обслуживания Dometic, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Dometic RM 7360(L) - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Dometic RM 7360(L), FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Dometic RM 7360(L), которое найдем в данном документе
3. Советы по использованию основных функций устройства Dometic RM 7360(L) - которые должны облегчить нам первые шаги во время использования Dometic RM 7360(L)
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Dometic RM 7360(L)
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Dometic RM 7360(L) в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Dometic RM 7360(L)?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Dometic RM 7360(L), задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Dometic RM 7360(L) со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)