  • Sharp AY-ZP48LZ - page 1

    AIR-TO-AIR HEA T PUMP OPERA TION MANUAL * Plasmacluster is a trademark of SHARP Corporation. INDOOR UNIT OUTDOOR UNIT A Y -ZP48LZ AE-Z48LZ ...

  • Sharp AY-ZP48LZ - page 2

    ...

  • Sharp AY-ZP48LZ - page 3

    1 This manual explains the proper use of your new heat pump. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. IMPORTANT SAFETY INSTRUCTIONS W ARNINGS FOR USE 1 This model should be installed with a fixed power cord to the meter box. 2 Be careful not to expose your body to th ...

  • Sharp AY-ZP48LZ - page 4

    2 P ART NAMES INDOOR UNIT 1 Inlet (Air) 2 Open Panel 3 Air Filter 4 Air purifying fi lter 5 AUX Button 6 Receiver Window 7 V ertical air fl ow Louvre 8 Horizontal air fl ow Louvre 9 Outlet (Air) 0 PLASMACLUSTER Lamp (blue) q OPERA TION Lamp (red ) w TIMER Lamp (orange ) e FULL POWER Lamp (green ) OUTDOOR UNIT r Inlet (Air) t Refrigerant Pipe and ...

  • Sharp AY-ZP48LZ - page 5

    3 REMOTE CONTROL 1 TRANSMITTER 2 DISPLA Y 3 COOL Button 4 DRY Button 5 HEA T Button 6 STOP Button 7 THERMOST A T Button 8 PLASMACLUSTER Button 9 SPOT AIR Button 0 FULL POWER Button q F AN Button w 1.2.3.5h OFF TIMER Button e SWING Button ( : vertical direction) r SWING Button ( : horizontal direction) t COANDA AIRFLOW Button y V ACANCY Button u ENE ...

  • Sharp AY-ZP48LZ - page 6

    4 SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o’clock in the afternoon Clock Display 12-hour mode PM 5:00 24-hour mode 17:00 1 T o set to the 12-hour mode, press the CLOCK button once. T o set to the 24-hour mode, press the CLOCK button twice. 2 Press the TIME ADV ANCE or REVERSE button to set the c ...

  • Sharp AY-ZP48LZ - page 7

    5 The air purifying filters are packed as accessory of this unit. During operation, the fi lters remove dust and tobacco smoke from the air and discharges clean air . 1 T ake out the air fi lters. 1 Open the open panel. 2 Push the air filters up slightly to unlock them. 3 Pull the air fi lters down to remove them. 2 Set the air purifying filter ...

  • Sharp AY-ZP48LZ - page 8

    6 1 Press the COOL, DR Y or HEA T button . : HEA T : COOL : DR Y • The red OPERA TION lamp ( ) on the unit will light. 2 T o change the temperature setting, press the THERMOST A T button. HEA T/COOL MODE • The temperature can be set within the range of 18°C to 32°C. DR Y MODE • The temperature can be changed up to 2°C above or below the te ...

  • Sharp AY-ZP48LZ - page 9

    7 HORIZONT AL AIR FLOW DIRECTION 1 Press the SWING button( ). • The horizontal air fl ow louvres will swing. 2 Press the SWING button( ) again when the horizontal air fl ow louvres are at the desired position. NOTE: • The adjusted position will be memorized and will be automatically set to the same position when operated the next time. • Th ...

  • Sharp AY-ZP48LZ - page 10

    8 SPOT AIR The louvres are adjusted so that air fl ow is delivered to the desired area. 1 Press the SPOT AIR button to select the desired air fl ow direction. NOTE: • If you want the SPOT AIR setting in the FULL POWER mode, press the SPOT AIR button during the FULL POWER operation. • The COANDA AIRFLOW setting and the SPOT AIR setting can not ...

  • Sharp AY-ZP48LZ - page 11

    9 The unit works at the maximum power and op- timum louvre direction to quickly cool or warm the room. 1 During operation, press the FULL POWER button. • The remote control will display “ ” and AIR FLOW symbol will get longer . • The temperature display will go off. • The green FULL POWER lamp ( ) on the unit will light up. • The vertic ...

  • Sharp AY-ZP48LZ - page 12

    10 1 . 2 . 3 . 5h OFF TIMER When the 1 . 2 . 3 . 5h OFF TIMER is set, the unit will automatically turn off after the set time (hours). 1 Press the 1 . 2 . 3 . 5h OFF TIMER button to set the desired time. • The time setting will change as you press the button as follows. • The orange TIMER lamp ( ) on the unit will light up. • The remaining op ...

  • Sharp AY-ZP48LZ - page 13

    11 TIMER ON 1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADV ANCE or REVERSE button to set the desired time. (The time can be set in 10-minute increments.) 3 Press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will light. 4 Select the operation condition. NOTE: • The unit will turn ...

  • Sharp AY-ZP48LZ - page 14

    12 PLASMACLUSTER OPERA TION Plasmacluster ions released into the room will reduce some airborne mold and viruses. 1 During operation, press the PLASMACLUSTER button. • The remote control will display “ ”. • The blue PLASMACLUSTER lamp on the unit will light up. TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on th ...

  • Sharp AY-ZP48LZ - page 15

    13 ADDITIONAL NOTES ON OPERA TION OPERA TING TEMPERA TURE RANGE V ACANCY OPERA TION Heating operation with 10°C set temperature will be performed to protect your home and furniture from frost damage, even when you are out. 1 Press the HEA T button. 2 Press the V ACANCY button. • The remote control will display “ 10°C ”. TO CANCEL Press the ...

  • Sharp AY-ZP48LZ - page 16

    14 MAINTENANCE AFTER HEA T PUMP SEASON 1 Operate the unit in the SELF CLEAN operation to allow the mechanism to thoroughly dry . 2 Stop the operation and turn off the circuit breaker . 3 Clean the fi lters, then reinstall them. MAINTENANCE BEFORE HEA T PUMP SEASON 1 Make sure that the air fi lters are not dirty . 2 Make sure that nothing obstruct ...

  • Sharp AY-ZP48LZ - page 17

    15 The following conditions do not denote equip- ment malfunctions UNIT DOES NOT OPERA TE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the unit. W ait 3 minutes before operating the unit. UNIT DOES NOT SEND OUT W ARM AIR The unit ...

  • Sharp AY-ZP48LZ - page 18

    16 ...

  • Sharp AY-ZP48LZ - page 19

    17 ...

  • Sharp AY-ZP48LZ - page 20

    18 Printed in Thailand TINSEA629JBRZ 09K- TH 1 ...

Производитель Sharp Категория Heat Pump

Документы, которые мы получаем от производителя устройства Sharp AY-ZP48LZ мы можем разделить на несколько групп. Это в частности:
- технические чертежи Sharp
- инструкции обслуживания AY-ZP48LZ
- паспорта изделия Sharp
- информационные брошюры
- энергетические этикетки Sharp AY-ZP48LZ
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Sharp AY-ZP48LZ.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Sharp AY-ZP48LZ, инструкции обслуживания, короткие инструкции или инструкции пользователя Sharp AY-ZP48LZ. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Sharp AY-ZP48LZ.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Sharp AY-ZP48LZ, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Sharp AY-ZP48LZ пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Sharp AY-ZP48LZ.

Полная инструкция обслуживания Sharp, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Sharp AY-ZP48LZ - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Sharp AY-ZP48LZ, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Sharp AY-ZP48LZ, которое найдем в данном документе
3. Советы по использованию основных функций устройства Sharp AY-ZP48LZ - которые должны облегчить нам первые шаги во время использования Sharp AY-ZP48LZ
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Sharp AY-ZP48LZ
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Sharp AY-ZP48LZ в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Sharp AY-ZP48LZ?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Sharp AY-ZP48LZ, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Sharp AY-ZP48LZ со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)