    SVM181-A Jan uar y , 2008 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PRE ...

  • Lincoln Electric POWER WAVE 355M - page 2

    SAFETY i i Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC FOR ENGINE powered equipment. 1.a. T ur n the engine off before troub leshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b . Operate engines in open, well-ven ...

  • Lincoln Electric POWER WAVE 355M - page 3

    SAFETY ii ii Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC FUMES AND GASES can be dangerous. 5.a. Welding ma y produce fumes and gases hazardous to health. A void breathing these fumes and gases.When welding, k eep your head out of the fume . Use enough ventilation and/or e xhaust at the arc to keep fumes ...

  • Lincoln Electric POWER WAVE 355M - page 4

    SAFETY iii iii Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Mar ‘95 FOR ELECTRICALL Y powered equipment. 8.a. T ur n off input power using the disconnect switch at the fuse bo x before working on the equipment. 8.b . Install equipment in accordance with the U .S. National Electrical Code, all local cod ...

  • Lincoln Electric POWER WAVE 355M - page 5

    SAFETY iv iv Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Mar ‘93 PRÉCAUTIONS DE SÛRETÉ P our votre propre protection lire et obser v er toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- an ...

  • Lincoln Electric POWER WAVE 355M - page 6

    SAFETY v v Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Electroma gnetic Compatibility (EMC) Conf or mance Products displa ying the CE mark are in conformity with European Community Council Directive of 3 Ma y 1989 on the appro ximation of the laws of the Member States relating to electromagnetic compati ...

  • Lincoln Electric POWER WAVE 355M - page 7

    SAFETY vi vi Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Electr omagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may e xtend beyond the boundaries of the premises. ...

  • Lincoln Electric POWER WAVE 355M - page 8

    - MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - I I POWER W A VE 355M/405M RETURN TO MAIN INDEX P age S a f e t y ........................................................................... i - v i I n s t a l l a t i o n .................................................................. S e c t i o nA O p e r a t i o n ............................. ...

  • Lincoln Electric POWER WAVE 355M - page 9

    T ABLE OF CONTENTS - INST ALLA TION SECTION A-1 A-1 Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M I n s t a l l a t i o n ............................................................................. A - 1 T e c h n i c a l S p e c i f i c a t i o n s3 5 5 M ........................ ...

  • Lincoln Electric POWER WAVE 355M - page 10

    INST ALLA TION A-2 A-2 POWER W A VE 355M/405M Return to Section T OC Return to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC TECHNICAL SPECIFICA TIONS - PO WER W A VE 355 INPUT A C V OL T A GE & DC OUTPUT Product Ordering Input AC Rated DC O ...

  • Lincoln Electric POWER WAVE 355M - page 11

    INST ALLA TION A-3 A-3 POWER W A VE 355M/405M Return to Section T OC Return to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC TECHNICAL SPECIFICA TIONS - PO WER W A VE 405 INPUT A C V OL T A GE & DC OUTPUT OUTPUT CABLES, CONNECTIONS AND LIMIT ...

  • Lincoln Electric POWER WAVE 355M - page 12

    INST ALLA TION A-4 A-4 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC ELECTRIC SHOCK can kill . • TURN THE INPUT PO WER OFF A T THE DISCONNECT SWITCH BEFORE A TTEMPTING TO CONNECT OR DIS ...

  • Lincoln Electric POWER WAVE 355M - page 13

    INST ALLA TION A-5 A-5 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 1 4.7 9 1 2 .4 4 3 .44 21.60 2 7.82 5.50 10.0 0 M OUNTING HOLE LOCATIONS M19527 13.1 0 1/4-20 NUT (4 PLACES) N OTE: MO ...

  • Lincoln Electric POWER WAVE 355M - page 14

    INST ALLA TION A-6 A-6 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Enable the v oltage sense leads as follo ws: T ABLE A.1 Process Electr ode V oltage W ork V oltage Sensing 67 lead * S ...

  • Lincoln Electric POWER WAVE 355M - page 15

    INST ALLA TION A-7 A-7 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SYSTEM DESCRIPTION The POWER W A VE 355M/405M and P ower Feed 10/11 f amily of products utilize a digital communicatio ...

  • Lincoln Electric POWER WAVE 355M - page 16

    INST ALLA TION A-8 A-8 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SYSTEM SET -UP Basic Rules • Each group is required to ha ve one user interf ace. No group may hav e more than one u ...

  • Lincoln Electric POWER WAVE 355M - page 17

    INST ALLA TION A-9 A-9 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FIGURE A.3 Multiple Gr oup System No “FH0 Allo wed! FIGURE A.4 Single Gr oup Multi-Head System No “FH0 Allo wed! T ...

  • Lincoln Electric POWER WAVE 355M - page 18

    INST ALLA TION A-10 A-10 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FIGURE A.5 Single Gr oup Multi-Head System (Alternate Method) No “FH0 Allo wed! When a standard User Interf ace is ...

  • Lincoln Electric POWER WAVE 355M - page 19

    INST ALLA TION A-11 A-11 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC WELDING WITH MUL TIPLE PO WER W A VES Special care must be taken when more than one P ower W ave is welding sim ulta ...

  • Lincoln Electric POWER WAVE 355M - page 20

    INST ALLA TION A-12 A-12 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC MUL TIPLE ARC UNSYNCHRONIZED SENSE LEAD AND WORK LEAD PLACEMENT GUIDELINES  ...

  • Lincoln Electric POWER WAVE 355M - page 21

    INST ALLA TION A-13 A-13 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC I / O RECEPT A CLE SPECIFICA TIONS T ABLE A.2 WIRE FEEDER RECEPT ACLE PIN LEAD# FUNCTION A 53 Communication Bus L B ...

  • Lincoln Electric POWER WAVE 355M - page 22

    INST ALLA TION A-14 A-14 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Most w elding applications r un with the electrode being positiv e (+). F or those applications, connect the elec- t ...

  • Lincoln Electric POWER WAVE 355M - page 23

    T ABLE OF CONTENTS - OPERA TION SECTION B-1 B-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Safety Pr ecautions ...

  • Lincoln Electric POWER WAVE 355M - page 24

    SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Unless using cold feed feature, when feeding with gun trigger , the elec- trode and drive mechanism are always electrically energized and could remain energized several sec- onds after the welding ceases. • Do not touch ...

  • Lincoln Electric POWER WAVE 355M - page 25

    OPERA TION B-3 B-3 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PO WER W A VE 355M/405M – Semi-A utomatic Operation Semi A utomatic P ower Wa ves can only be used with Arclink compatib ...

  • Lincoln Electric POWER WAVE 355M - page 26

    OPERA TION B-4 B-4 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FIGURE B.1 10 4 6 1 3 2 5 7 8 9 CASE FR ONT LA Y OUT PO WER W A VE 355M/405M 5. Inter nal PO WER CIRCUIT BREAKER: Protects ...

  • Lincoln Electric POWER WAVE 355M - page 27

    OPERA TION B-5 B-5 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC In non-synergic modes, the WFS control behav es more like a conv entional CV power source where WFS and v oltage are indep ...

  • Lincoln Electric POWER WAVE 355M - page 28

    OPERA TION B-6 B-6 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC TIG GT A W The TIG mode features continuous control from 5 to 425 amps. The TIG mode can be r un in either the T ouch Star ...

  • Lincoln Electric POWER WAVE 355M - page 29

    P ower Mode™ is a method of high speed regulation of the output power whene ver an arc is established. It provides a f ast response to changes in the arc. The higher the P ower Mode Setting, the longer the arc. If a welding procedure is not established, the best way to determine the P ower Mode Setting is b y e xperimenta- tion until the desired ...

  • Lincoln Electric POWER WAVE 355M - page 30

    OPERA TION B-8 B-8 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SPECIAL WELDING PROCESSES A V AILABLE ON THIS MA CHINE PULSE WELDING (GMA W -P) The pulsed-arc process is, by definition, ...

  • Lincoln Electric POWER WAVE 355M - page 31

    OPERA TION B-9 B-9 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FIGURE B.3 Current Time CURRENT W A VE FORM (PULSE) PULSE WELDING Pulse welding procedures are set by controlling an ov er ...

  • Lincoln Electric POWER WAVE 355M - page 32

    OPERA TION B-10 B-10 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PULSE-ON-PULSE™ (GMA W -PP) Pulse on Pulse™ is a Lincoln process specifically designed f or use in welding relativel ...

  • Lincoln Electric POWER WAVE 355M - page 33

    T ABLE OF CONTENTS - ACCESSORIES SECTION C-1 C-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1 Optional Equipment . ...

  • Lincoln Electric POWER WAVE 355M - page 34

    ACCESSORIES C-2 C-2 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC OPTIONAL EQUIPMENT F ACT OR Y INST ALLED None A vailab le. FIELD INST ALLED K940-W ork V oltage Sense Lead Kit K1764-1-Un ...

  • Lincoln Electric POWER WAVE 355M - page 35

    T ABLE OF CONTENTS - MAINTENANCE SECTION D-1 D-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 Safety Pr ecautions .. ...

  • Lincoln Electric POWER WAVE 355M - page 36

    MAINTENANCE D-2 D-2 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Have qualified personnel do the maintenance work. Always use the greatest care when working near mo ving par ts. Do not p ...

  • Lincoln Electric POWER WAVE 355M - page 37

    MAINTENANCE D-3 D-3 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC W A R N I N G W A R N I N G A V I S O D E  P R E C A U C I O N A T T E N T I O N ! ! ! ! L o r e m i p s u m d o l o r ...

  • Lincoln Electric POWER WAVE 355M - page 38

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES D-4 D-4 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 39

    T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1 General Descriptio ...

  • Lincoln Electric POWER WAVE 355M - page 40

    GENERAL DESCRIPTION The Power W ave semi-automatic po wer source is designed to be a part of a modular , multi-process welding system. Depending on configuration, it can support constant current, constant voltage, and pulse welding modes. The Power W ave power sour ce is designed to be used with the semi-automatic family of power feed wire feeders, ...

  • Lincoln Electric POWER WAVE 355M - page 41

    THEOR Y OF OPERA TION E-3 E-3 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC SWITCH BOARD & MAIN TRANSFORMER There is one switch board in the POWER WA VE 355M/405M. This board incorpor ...

  • Lincoln Electric POWER WAVE 355M - page 42

    THEOR Y OF OPERA TION E-4 E-4 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NO TE: Unshaded areas of Block Logic Diagram are the subject of discussion FIGURE E.4 – POWER BOARD, CONTROL ...

  • Lincoln Electric POWER WAVE 355M - page 43

    THEOR Y OF OPERA TION E-5 E-5 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NO TE: Unshaded areas of Block Logic Diagram are the subject of discussion OUTPUT RECTIFIER AND CHOKE The outpu ...

  • Lincoln Electric POWER WAVE 355M - page 44

    THEOR Y OF OPERA TION E-6 E-6 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC THERMAL PROTECTION Three normally closed (NC) thermostats protect the machine from excessive operating temperat ...

  • Lincoln Electric POWER WAVE 355M - page 45

    THEOR Y OF OPERA TION E-7 E-7 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC INSULA TED GA TE BIPOLAR TRANSISTOR (IGBT) OPERA TION An IGBT is a type of transistor . IGBT are semiconduc- to ...

  • Lincoln Electric POWER WAVE 355M - page 46

    THEOR Y OF OPERA TION E-8 E-8 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PULSE WIDTH MODULA TION The term Pulse Width Modulation is used to describe how much time is devoted to conduct ...

  • Lincoln Electric POWER WAVE 355M - page 47

    T ABLE OF CONTENTS - TROUBLESHOOTING AND REP AIR F-1 F-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1 How to Use T roubleshoot ...

  • Lincoln Electric POWER WAVE 355M - page 48

    TROUBLESHOOTING AND REP AIR F-2 F-2 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC This T roubleshooting Guide is pro vided to help you locate and repair possible machine malfunctions. Sim ...

  • Lincoln Electric POWER WAVE 355M - page 49

    TROUBLESHOOTING AND REP AIR F-3 F-3 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Sometimes machine f ailures appear to be due to PC board failures . These problems can sometimes be trace ...

  • Lincoln Electric POWER WAVE 355M - page 50

    OUTPUT PROBLEMS Obser v e Saf ety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not understand the test procedure s or are unab le to perform the tests/repairs saf ely , contact the Lincoln Electr ic Service Department f or technica ...

  • Lincoln Electric POWER WAVE 355M - page 51

    OUTPUT PROBLEMS Obser v e Saf ety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not understand the test procedure s or are unab le to perform the tests/repairs saf ely , contact the Lincoln Electr ic Service Department f or technica ...

  • Lincoln Electric POWER WAVE 355M - page 52

    FUNCTION PROBLEMS Obser v e Saf ety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not understand the test procedure s or are unab le to perform the tests/repairs saf ely , contact the Lincoln Electr ic Service Department f or techni ...

  • Lincoln Electric POWER WAVE 355M - page 53

    FUNCTION PROBLEMS Obser v e Saf ety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not understand the test procedure s or are unab le to perform the tests/repairs saf ely , contact the Lincoln Electr ic Service Department f or techni ...

  • Lincoln Electric POWER WAVE 355M - page 54

    FUNCTION PROBLEMS Obser v e Saf ety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any r eason y ou do not understand the test procedure s or are unab le to perform the tests/repairs saf ely , contact the Lincoln Electr ic Service Department f or techni ...

  • Lincoln Electric POWER WAVE 355M - page 55

    TROUBLESHOOTING AND REP AIR F-9 F-9 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC USING THE ST A TUS LED T O TROUBLESHOOT SYSTEM PROBLEMS The Power Wave / Power Feed are best diagnosed as ...

  • Lincoln Electric POWER WAVE 355M - page 56

    ERROR CODES FOR THE POWER WA VE The following is a list of possible error codes that the POWER WA VE 355M/405M can output via the status light If connected to a PF-10/11 these error codes will generally be accompanied by an “Err 006” or “Err 100” on the user interface display . Individual code digits are flashed in RED with a long pause bet ...

  • Lincoln Electric POWER WAVE 355M - page 57

    TROUBLESHOOTING AND REP AIR F-11 F-11 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 43 Capacitor delta err or . The maximum voltage differ ence between the main capaci- tors has been exce ...

  • Lincoln Electric POWER WAVE 355M - page 58

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-12 F-12 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 59

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 60

    TROUBLESHOOTING AND REP AIR F-14 F-14 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC ELECTRIC SHOCK can kill. • Have an electrician install and service this equipment. • T ur n the inp ...

  • Lincoln Electric POWER WAVE 355M - page 61

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 62

    TROUBLESHOOTING AND REP AIR F-16 F-16 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC MAIN SWITCH BOARD TEST (continued) FIGURE F .2 MAIN SWITCH BOARD LEAD LOCA TIONS TEST PROCEDURE 1. Remo ...

  • Lincoln Electric POWER WAVE 355M - page 63

    TROUBLESHOOTING AND REP AIR F-17 F-17 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC MAIN SWITCH BOARD TEST (continued) T ABLE F .1. SWITCH BOARD RESIST ANCE TEST 6. If any test fails repl ...

  • Lincoln Electric POWER WAVE 355M - page 64

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-18 F-18 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 65

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 66

    TROUBLESHOOTING AND REP AIR F-20 F-20 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC TEST PROCEDURE 1. Remove input power to the POWER WA VE 355M/405M machine. 2. Using a 5/16” nut drive ...

  • Lincoln Electric POWER WAVE 355M - page 67

    A B C A B C A B C 207 207 207 207A 207A 207A 209 209 209 TROUBLESHOOTING AND REP AIR F-21 F-21 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 9. If the input rectifier does not meet the ac ...

  • Lincoln Electric POWER WAVE 355M - page 68

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-22 F-22 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 69

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 70

    TEST PR OCEDURE 1. Remov e input power to the P ower W av e 355M/405M. 2. Using the 3/8” n ut dr iv er , remove the case top . 3. Per for m th e Capacitor Discharge Procedure . 4. Locate the P ower Board and plugs J42 and J43. Do not remove plugs or leads from the P ower Boar d . Ref er to Figure F .8. 5. Carefully apply input power to the P ower ...

  • Lincoln Electric POWER WAVE 355M - page 71

    TROUBLESHOOTING AND REP AIR F-25 F-25 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER BOARD TEST (CONTINUED) T ABLE F .3 – POWER BOARD VOL T AGE CHECKS CHECK POINT LOCA TION TEST DE ...

  • Lincoln Electric POWER WAVE 355M - page 72

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-26 F-26 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 73

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 74

    TEST PR OCEDURE 1. Remove input power to the machine. 2. Using the 3/8” nut dr iv er , remov e the wrap- around cov er . 3. Locate the DC Bus Board. See Figure F .5. 4. Carefully apply input power to the P ow er W ave 355M/405M. ELECTRIC SHOCK can kill. High voltage is present when input power is applied to the machine. 5. T ur n on the P ow er W ...

  • Lincoln Electric POWER WAVE 355M - page 75

    TROUBLESHOOTING AND REP AIR F-29 F-29 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC DC BUS BOARD TEST (CONTINUED) 6. Check the DC Bus Board input and output voltages according to T ab le ...

  • Lincoln Electric POWER WAVE 355M - page 76

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-30 F-30 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 77

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 78

    TROUBLESHOOTING AND REP AIR F-32 F-32 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC OUTPUT RECTIFIER MODULES TEST (continued) TEST PROCEDURE 1. Remove input power to the POWER W AVE 355M/ ...

  • Lincoln Electric POWER WAVE 355M - page 79

    TROUBLESHOOTING AND REP AIR F-33 F-33 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC OUTPUT RECTIFIER MODULES TEST (continued) 5. If 200 ohms is measur ed then the output diodes ar e not ? ...

  • Lincoln Electric POWER WAVE 355M - page 80

    TROUBLESHOOTING AND REP AIR F-34 F-34 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Figure F .9 Snubber and Output Diode Locations LEFT SIDE Snubber Board Output Diode Modules ...

  • Lincoln Electric POWER WAVE 355M - page 81

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 82

    TROUBLESHOOTING AND REP AIR F-36 F-36 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC AUXILIAR Y TRANSFORMER TEST (continued) TEST PROCEDURE 1. Remove input power to the POWER WA VE 355M/40 ...

  • Lincoln Electric POWER WAVE 355M - page 83

    TROUBLESHOOTING AND REP AIR F-37 F-37 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 7. Carefully apply the corr ect input voltage to the POWER WA VE 355M/405M and check for the correct se ...

  • Lincoln Electric POWER WAVE 355M - page 84

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-38 F-38 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 85

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 86

    TROUBLESHOOTING AND REP AIR F-40 F-40 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC TEST PROCEDURE 1. Remove input power to the POWER W A VE 355M/405M. 2. Using the 5/16” nut driver , r ...

  • Lincoln Electric POWER WAVE 355M - page 87

    TROUBLESHOOTING AND REP AIR F-41 F-41 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC AUXILIAR Y TRANSFORMER TEST (continued) 8. Check the feedback voltage from the current transducer using ...

  • Lincoln Electric POWER WAVE 355M - page 88

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-42 F-42 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 89

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 90

    F AN CONTROL AND MOTOR TEST (continued) TROUBLESHOOTING AND REP AIR F-44 F-44 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC TEST PROCEDURE 1. Remove the input power to the POWER W A VE 35 ...

  • Lincoln Electric POWER WAVE 355M - page 91

    F AN CONTROL AND MOTOR TEST (continued) TROUBLESHOOTING AND REP AIR F-45 F-45 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Plug J20 Lead 715+ 1 2 3 4 7 8 6 5 Lead 716- 7. If the 115V AC ...

  • Lincoln Electric POWER WAVE 355M - page 92

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-46 F-46 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 93

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 94

    TROUBLESHOOTING AND REP AIR F-48 F-48 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA VE 355M/405M. 2. Using a 5/16” nut driver remove the ...

  • Lincoln Electric POWER WAVE 355M - page 95

    TROUBLESHOOTING AND REP AIR F-49 F-49 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Observe static precautions detailed in PC Board T roubleshooting Procedures at the beginning of this se ...

  • Lincoln Electric POWER WAVE 355M - page 96

    TROUBLESHOOTING AND REP AIR F-50 F-50 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC CONTROL BOARD REMOV AL AND REPLACEMENT (continued) 12. Using a 3/8” nut driver remove the two mountin ...

  • Lincoln Electric POWER WAVE 355M - page 97

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 98

    MAIN SWITCH BOARD REMOV AL & REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-52 F-52 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove the input power to the POW ...

  • Lincoln Electric POWER WAVE 355M - page 99

    MAIN SWITCH BOARD REMOV AL & REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-53 F-53 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC FIGURE F .22 – 3/16” ALLEN BOL T LOCA TION ...

  • Lincoln Electric POWER WAVE 355M - page 100

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-54 F-54 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 101

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 102

    SNUBBER BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-56 F-56 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA VE 3 ...

  • Lincoln Electric POWER WAVE 355M - page 103

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 104

    POWER BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-58 F-58 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA VE 355 ...

  • Lincoln Electric POWER WAVE 355M - page 105

    POWER BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-59 F-59 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Observe static prec autions detailed in PC Board T rou ...

  • Lincoln Electric POWER WAVE 355M - page 106

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-60 F-60 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 107

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 108

    DC BUS BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-62 F-62 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA VE 35 ...

  • Lincoln Electric POWER WAVE 355M - page 109

    DC BUS BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-63 F-63 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 9. Label and remove two thermostat leads and four lea ...

  • Lincoln Electric POWER WAVE 355M - page 110

    DC BUS BOARD REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-64 F-64 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 16. Replace the two 5/16” mounting screws to the bo ...

  • Lincoln Electric POWER WAVE 355M - page 111

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 112

    INPUT RECTIFIER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-66 F-66 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA VE ...

  • Lincoln Electric POWER WAVE 355M - page 113

    INPUT RECTIFIER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-67 F-67 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 9. Apply a thin coat of Penetrox A-13 heatsink com ...

  • Lincoln Electric POWER WAVE 355M - page 114

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-68 F-68 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 115

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 116

    OUTPUT RECTIFIER MODULES REMOV AL AND REPLACEMENT (con’t) TROUBLESHOOTING AND REP AIR F-70 F-70 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWE ...

  • Lincoln Electric POWER WAVE 355M - page 117

    OUTPUT RECTIFIER MODULES REMOV AL AND REPLACEMENT (con’t) TROUBLESHOOTING AND REP AIR F-71 F-71 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 8. Under the copper plate previously remove ...

  • Lincoln Electric POWER WAVE 355M - page 118

    Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC NOTES F-72 F-72 POWER W A VE 355M/405M ...

  • Lincoln Electric POWER WAVE 355M - page 119

    Ser vice and repair should be perf or med by only Lincoln Electric factory trained personnel. Unauthorized repairs perf or med on this equipment may result in danger to the technician or machine oper ator and will in validate your f actor y warr anty . F or your saf ety and to av oid electrical shock, please observe all safety notes and precautions ...

  • Lincoln Electric POWER WAVE 355M - page 120

    CURRENT TRANSDUCER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-74 F-74 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC PROCEDURE 1. Remove input power to the POWER WA ...

  • Lincoln Electric POWER WAVE 355M - page 121

    CURRENT TRANSDUCER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-75 F-75 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 5. Label and remove the four leads connected to ...

  • Lincoln Electric POWER WAVE 355M - page 122

    CURRENT TRANSDUCER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-76 F-76 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 11. The back of the machine may now gently be p ...

  • Lincoln Electric POWER WAVE 355M - page 123

    CURRENT TRANSDUCER REMOV AL AND REPLACEMENT (continued) TROUBLESHOOTING AND REP AIR F-77 F-77 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC 21. Replace the current transducer . 22. Replac ...

  • Lincoln Electric POWER WAVE 355M - page 124

    TROUBLESHOOTING AND REP AIR F-78 F-78 POWER W A VE 355M/405M Return to Section T OC Retur n to Section T OC Retur n to Section T OC Retur n to Section T OC Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC Retest a machine: If it is rejected under test for any reason that requires you to remove any par t whi ...

  • Lincoln Electric POWER WAVE 355M - page 125

    T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 Return to Master T OC Retur n to Master T OC Retur n to Master T OC Retur n to Master T OC POWER W A VE 355M/405M Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Wiring Diagram (G4131) . . . . ...

  • Lincoln Electric POWER WAVE 355M - page 126

    ELECTRICAL DIAGRAMS G-2 POWER W A VE 355M/405M WIRING DIAGRAM - POWERW AVE 355/405 - G4131 NOTES: N.A. 1. FO R MACHI NES WIT H RE D, BLAC K AND WHITE POWE R COR DS- FOR SI NGLE PH ASE INP UT: CONN ECT GRE EN LEAD TO G ROUN D PER NATI ONAL EL ECTRIC AL CODE. CONN ECT BL ACK A ND WHIT E LEA DS TO SUPPL Y CIRC UIT. WR AP RE D LEA D WITH T APE TO PR OV ...

  • Lincoln Electric POWER WAVE 355M - page 127

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-3 POWER W A VE 355M/405M SCHEMA TIC - COMPLETE MACHINE EN-170 G4132 POW ERWA VE 355/405 MACHINE SC HEMATIC NONE G4093 F.Valencic L.Petrila J.O'Connor ...

  • Lincoln Electric POWER WAVE 355M - page 128

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-4 POWER W A VE 355M/405M SCHEMA TIC - DIGITAL CONTROL PC BOARD #1 G-4 NOTE: This diagram is for reference only . It may not be accurate for all machines co ...

  • Lincoln Electric POWER WAVE 355M - page 129

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-5 POWER W A VE 355M/405M SCHEMA TIC - DIGITAL CONTROL PC BOARD #2 G-5 NOTE: This diagram is for reference only . It may not be accurate for all machines co ...

  • Lincoln Electric POWER WAVE 355M - page 130

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-6 POWER W A VE 355M/405M SCHEMA TIC - DIGITAL CONTROL PC BOARD #3 G-6 NOTE: This diagram is for reference only . It may not be accurate for all machines co ...

  • Lincoln Electric POWER WAVE 355M - page 131

    ELECTRICAL DIAGRAMS G-7 POWER W A VE 355M/405M SCHEMA TIC - DIGITAL CONTROL PC BOARD #4 G-7 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric POWER WAVE 355M - page 132

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-8 POWER W A VE 355M/405M SCHEMA TIC - POWER SUPPL Y PRINTED CIRCUIT BOARD .1 C53 Vfb2 Vref 1 100K R29 CNY17-3 OCI2 42 1 6 5 .5W 27V DZ2 VFB CS COMP RT/CT V ...

  • Lincoln Electric POWER WAVE 355M - page 133

    ELECTRICAL DIAGRAMS G-9 POWER W A VE 355M/405M SCHEMA TIC - SWITCH PC BOARD G-9 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to M ...

  • Lincoln Electric POWER WAVE 355M - page 134

    NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub ...

  • Lincoln Electric POWER WAVE 355M - page 135

    Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-11 POWER W A VE 355M/405M SCHEMA TIC - SNUBBER PC BOARD S24761 6-2-2000 G-11 NOTE: This diagram is for reference only . It may not be accurate for all mach ...

  • Lincoln Electric POWER WAVE 355M - page 136

    NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is pro- vided for reference only . Lincoln Electric discourages board level troub ...

  • Lincoln Electric POWER WAVE 355M - page 137

    ELECTRICAL DIAGRAMS G-13 POWER W A VE 355M/405M SCHEMA TIC - 40 VDC BUSS PC BOARD G-13 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. Return to Section TOC Retur n to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Retu ...

Производитель Lincoln Electric Категория Welder

Документы, которые мы получаем от производителя устройства Lincoln Electric POWER WAVE 355M мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lincoln Electric
- инструкции обслуживания POWER WAVE 355M
- паспорта изделия Lincoln Electric
- информационные брошюры
- энергетические этикетки Lincoln Electric POWER WAVE 355M
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lincoln Electric POWER WAVE 355M.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lincoln Electric POWER WAVE 355M, инструкции обслуживания, короткие инструкции или инструкции пользователя Lincoln Electric POWER WAVE 355M. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lincoln Electric POWER WAVE 355M.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lincoln Electric POWER WAVE 355M, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lincoln Electric POWER WAVE 355M пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lincoln Electric POWER WAVE 355M.

Полная инструкция обслуживания Lincoln Electric, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lincoln Electric POWER WAVE 355M - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lincoln Electric POWER WAVE 355M, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lincoln Electric POWER WAVE 355M, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lincoln Electric POWER WAVE 355M - которые должны облегчить нам первые шаги во время использования Lincoln Electric POWER WAVE 355M
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lincoln Electric POWER WAVE 355M
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lincoln Electric POWER WAVE 355M в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lincoln Electric POWER WAVE 355M?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lincoln Electric POWER WAVE 355M, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lincoln Electric POWER WAVE 355M со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)