    Installation, Operation & Diagnostics for the MIU/PowerPort Series / 2.4 / 9.6 / 14.4 / 28.8 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-002 ...

  • Telenetics 2.4 - page 2

    Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 Telephone (949)455-4000 Fax (949)455-4010 Document No. 49-0002-002 ...

  • Telenetics 2.4 - page 3

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 1 TABLE of CONTENTS 1. STANDARDS .................................................................................... Page 2 2. PRODUCT OVERVIEW ................................................................... Page 3 3. GENERAL PRODUCT SPECIFICATIONS ................... ...

  • Telenetics 2.4 - page 4

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 2 1. STANDARDS All Telenetics di al-up modem s are designed to meet the following Standards: USA: FCC Part 15, Class A and Part 68 Canada: DOC Standards CS-01, CS-02 and CS -03 CANADIAN DEPARTMENT OF COMMUNICATION NOTICE NOTICE: The Canadian Departm ent of Comm unicati ons ...

  • Telenetics 2.4 - page 5

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 3 2. PRODUCT OVERVIEW The MIUPowerPortX.X Series are i ndustrial grade dial and leased line modem s for connection to the Public Swit ched Telephone Network.. They can be powered from a wide range of AC and DC power suppl ies, they are internally surge protected on both th ...

  • Telenetics 2.4 - page 6

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 4 Industrial: The MIU PowerPort is packaged in a rugged, compact, non-metallic (ABS) enclosure. Designed for unmanned locations, t he MIUs do not include the array of pushbuttons and LEDs norm ally associ ated with consumer-type modems to increase reliability and decrease ...

  • Telenetics 2.4 - page 7

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 5 3. GENERAL PRODUCT SPECIFICATIONS Dimensi ons: 5.3 x 4.0 x 1.375 inches Weight: 1 lb Voltage Supply: : 8 to 24 VDC 7 to 16 VAC, 50/60 Hz Optional Wall Transform er 115 VAC, 50/60 Hz Current Requirem ents: (See Section 4 for Power Down M odes) MIU PowerPort 2.4: 12VDC 24V ...

  • Telenetics 2.4 - page 8

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 6 4. POWER MODES Mode Description Power Consumption Power On Factory Setting : Full power is always available to the modem. See Section 3 Sleep If the modem is on hook for a predetermined peri od (PE2400 = 5 seconds; PE2496, PE14.4 & PE28.8 = software configured: Set S ...

  • Telenetics 2.4 - page 9

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 7 5. MODEM SPECIFICATIONS MIU2.4 MIU9.6 MIU14.4 MIU28.8 Standards V.22bis V.22 Bell212A Bell 103 V.22bis V.22 Bell212A Bell 103 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 V.34 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 Modem Line Speed (Asynch) 2400bps 1200bps 300bps 240 ...

  • Telenetics 2.4 - page 10

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 8 6. POWER CONNECTIONS DC Power Jack, 2.0mm – This standard concentri c jack is provided to attach an external power source in the range of 7 – 16 VAC or 8 – 24 VDC . The 2.0mm Jack connects through a full wave bridge so either polarity is acceptable from the DC sour ...

  • Telenetics 2.4 - page 11

    7. SERIAL DATA PORT PIN-OUTS MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 9 ...

  • Telenetics 2.4 - page 12

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 10 8. DIP SWITCH SETTINGS Not Applicable – The dip switches are on the PE Modul e. Contact factory for non – standard settings. * NOTE: Opening the MIU for any reason voids t he factory warranty. ...

  • Telenetics 2.4 - page 13

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 11 9. LED INDICATOR The MIU has a single LED that w ill indicate the following conditions... 4 Blinking: POWER ON 4 Steady: MODEM CONNECTED (CARRIER DETECT) 10. AUTO RESET FEATURE The dial-up m odem m odules inside your MIU include an “Aut o Reset” feature: If the mode ...

  • Telenetics 2.4 - page 14

    12. OUTLINE DRAWING & MOUNTING MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 12 ...

  • Telenetics 2.4 - page 15

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 13 13. MODEM CONFIGURATION Telenetics dial and leased l ine modems are based upon Rockwell chipsets. These chipsets contain Rockwell’s “AT” comma nd set. A summary of the Rockwell comm and set for your MIU m odem is provided in Book 2. Unless otherwise specified at t ...

  • Telenetics 2.4 - page 16

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 14 14. FACTORY CONFIGURATION ~ MIU2.4 ACTIVE PROFILE: B1 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D0 &G0 &J0 &L0 &P0 &Q0 &R0 &S0 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:030 S08:002 S09: 006 S10:014 S12:050 S14:AAH S ...

  • Telenetics 2.4 - page 17

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 15 14. FACTORY CONFIGURATION ~ MIU9.6 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:050 S08: 002 S09:006 S10:014 S11:095 S ...

  • Telenetics 2.4 - page 18

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 16 14. FACTORY CONFIGURATION ~ MIU14.4 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:050 S08: 002 S09:006 S10:014 S11:095 ...

  • Telenetics 2.4 - page 19

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 17 14. FACTORY CONFIGURATION ~ MIU28.8 ACTIVE PROFILE: B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:030 S08: 002 S09:006 S10:014 S11:255 ...

  • Telenetics 2.4 - page 20

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 18 15. DIAGNOSTICS The following pages provide softwa re and hardware t echniques for diagnosing comm unication problem s and thereby isol ating the problem at either the local modem, the remote modem or the interconnecting lin e. The following AT&Tn comm ands form par ...

  • Telenetics 2.4 - page 21

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 19 &T0 TERMINATE TEST IN PROGRESS If a V.54 loopback test is in progress as a resul t of executing an &Tn command, then the &T0 command will cause that test to be terminated, provided that the modem is in the comm and state or a V.54 state that accepts comma nd ...

  • Telenetics 2.4 - page 22

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 20 &T2 NO FUNCTION &T3 PERFORM LOCAL DIGITAL LOOPBACK (See Figure 3) The modem must be in the comm and state with connection est ablished when this command is issued, otherw ise an ERROR result code occurs. The AT&T3 command establishes a loopback of received d ...

  • Telenetics 2.4 - page 23

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 21 &T5 DENY RDL REQUESTS The modem will not respond to a rem o te digital loopback request from a distant modem. This will result in an error if the command is given wh ile any V.54 test is acti ve (&T1, &T3, &T6, &T7 or &T8). &T6 INITIATE REMOT ...

  • Telenetics 2.4 - page 24

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 22 This is a system test, end to end. The comm and is valid only i f the mode m s are in the comm and state with a connection established. Configure th e remote modem with an AT&T4 comm and so that it will honor a remote digi tal loopback request. Enter AT&T7 at th ...

  • Telenetics 2.4 - page 25

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 23 &T8 LOCAL LOOPBACK WITH SELF TEST (See Figure 6) The modem should be on hook. Enter AT&T8 to configure the m odem for analog loopback and self test. The t est timer i s started at the ti me indicated by S18, DSR i s turned off (i f &S1 is in effect). A self ...

  • Telenetics 2.4 - page 26

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 24 ...

  • Telenetics 2.4 - page 27

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 25 ...

  • Telenetics 2.4 - page 28

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 26 ...

  • Telenetics 2.4 - page 29

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 27 ADDITIONAL TEST / DIAGNOSTICS COMMANDS... %L RECEIVED SIGNAL LEVEL Returns a value (-dBm) which indicates the received signal level at modem DATA PUMP interface. This value is determined by the loss/gain of m odem Telco Interface circuit ±dB at the Tip/R ing input to t ...

  • Telenetics 2.4 - page 30

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 28 0 Normal hang up; no error occurred. 4 Physical carrier loss. (Loss of Carrier) 5 Feature negotiation fai led to detect presence of another V.42 error-control modem at other end. 6 Other error-control m odem did not respond to feature negotiation m essage sent by this m ...

  • Telenetics 2.4 - page 31

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 29 NOTES: ...

Производитель Telenetics Категория Network Card

Документы, которые мы получаем от производителя устройства Telenetics 2.4 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Telenetics
- инструкции обслуживания 2.4
- паспорта изделия Telenetics
- информационные брошюры
- энергетические этикетки Telenetics 2.4
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Telenetics 2.4.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Telenetics 2.4, инструкции обслуживания, короткие инструкции или инструкции пользователя Telenetics 2.4. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Telenetics 2.4.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Telenetics 2.4, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Telenetics 2.4 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Telenetics 2.4.

Полная инструкция обслуживания Telenetics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Telenetics 2.4 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Telenetics 2.4, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Telenetics 2.4, которое найдем в данном документе
3. Советы по использованию основных функций устройства Telenetics 2.4 - которые должны облегчить нам первые шаги во время использования Telenetics 2.4
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Telenetics 2.4
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Telenetics 2.4 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Telenetics 2.4?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Telenetics 2.4, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Telenetics 2.4 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)