Инструкция обслуживания Graco 24J393

18 страниц 1.11 mb
Скачать

Перейти на страницу of 18

Summary
  • Graco 24J393 - page 1

    Instr uctions GBL 7500 Bo x Lubricator Pump GBL Shaft Rotation/Lo w Le vel Alarm Pump 3A2257C EN GBL 7500 Bo x Lubricator Pump: Fully enc losed, self-lubricati ng, precision, metering pump capable of pumping small flows of either mineral or synthetic oil to machinery injection points. For prof essional use only . GBL Shaft Rotation/Low Le vel Alarm ...

  • Graco 24J393 - page 2

    Warnings 2 3A2257C Wa r n i n g s The f ollowing w ar nings are f or the setup , use , grounding, maintenan ce, and repair of this equipme nt. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols ref er to procedur e-specific risks. When these symbols appear in the body of this manual , ref er ba ck to these W a ...

  • Graco 24J393 - page 3

    Warnings 3A2257C 3 EQUIPMENT MISUSE HAZARD Misuse can caus e death or ser ious injur y . • Do not oper ate the unit when f atigued or under the influence of drugs or alcoh ol. • Do not e xceed the maxim um working pressure or temper ature rating of the low est rated system compo - nent. See Te c h n i c a l D a t a in all equipme nt manuals. ? ...

  • Graco 24J393 - page 4

    Warnings 4 3A2257C Pressure Relief Pr ocedure 1. Stop lube pu mp. 2. If installed, close oil supply v alv e located upstre am from pump. 3. If installed, open drain v alv e located downst ream from the pump . 4. Slowly cr ack open fluid line fit tings to relie ve pr es- sure. Installing the Pump Gr ounding Ensure the reservoir is properly grou nded ...

  • Graco 24J393 - page 5

    Setup 3A2257C 5 b . F or all installations (whether the tube needs to be tr immed or ca n be used wit hout tr imming), press strainer onto end of the suction tube until it “bottoms” (F IG . 3). 4. Orient pump so the roller bearing on the bottom of the pump is aligned with the cam insid e the reser- vo ir. 5. Install pump on the reser v oir by a ...

  • Graco 24J393 - page 6

    Setup 6 3A2257C Suction Fed Models (F IG . 4) 1. Remov e the sight w ell plug (1) and outlet plug (5 ). Discard outlet plug (5). 2. Fill the sight well (2) to th e top with appropriately fil- tered oil. 3. Operate th e hand priming assembly (3) until t he oil le vel dro ps below the end of th e drip tube (4). 4. Apply th read sealant (user supp lie ...

  • Graco 24J393 - page 7

    Setup 3A2257C 7 Pressure Fed Models (F IG . 6) NO TE: In the f ollowing instructions , the fill line ref ers to the inlet line. 1. Remov e and d iscard the inlet p lug (1) and o utlet plug (5). 2. Apply thread sealant (user supplied) to fill line fitting. 3. Connect fill line to inlet (2). 4. T orque fill line fitting to 85 + 10 in. lbs (9.60 + 1.1 ...

  • Graco 24J393 - page 8

    Setup 8 3A2257C Connecting Lube Lines to Pump: Suction, Gravity and Pressur e Fed Pump Models Only NO TE: The lube line ref ers to the outlet line supplying lubricant to the lubr ication points. 1. Apply th read sealant (user supplied ) to lube line f it- ting. 2. Connect lube line to pump out let (6), (F IG . 8)(also see pages 15 and 16). 3. T orq ...

  • Graco 24J393 - page 9

    Setup 3A2257C 9 3. For Suction Fed and Gravity Fed models onl y: With the lubricator oper ating, count the dr ops from the drip tube (4) falling into the sight w ell (2) fo r one minute . The number of drops seen f a lling in the sight well equals the amount of oil discha rged by the pump . See Specifi- cations , page 10 f or additional inf or mati ...

  • Graco 24J393 - page 10

    Specifications 10 3A2257C Specifications Ta b l e 1 Drops per Stroke T able Section of T able A pplies to Suction and Gra vity Fed Models Only • Allow able viscosity range independent of te mperature: 80-50 00 SUS. • Strok es/Minute - Maxim um - 50; Minimum - 3 • Strok e Length - Maximum 1/ 2 inch (12.7 mm) † Ref er to your manuf acturer’ ...

  • Graco 24J393 - page 11

    Troubleshooting 3A2257C 11 T roub leshooting * Oil le vel in sight well will rise and f all dur ing nor mal operati on. If condition persis ts refer to Cause/ Solution sections. I Prob lem Cause Solution Pump does not flo w Pump stroke is adjusted to zero . Adjust pump stroke f or desired out- put. See page 8. Pump outlet is plugg ed. Clean/flush p ...

  • Graco 24J393 - page 12

    Maintenance 12 3A2257C Maintenance Sight W ell Fills With Oil The oil le vel in the sight well (2) will rise and fall slightly during pump operation . Should the oil le vel in t he sight well rise abov e the dr ip tube (4): 1. Remove the sight well plug ( 1). 2. Allow the pump to continue to opera te until the oil le vel has dropped belo w the drip ...

  • Graco 24J393 - page 13

    Technical Data 3A2257C 13 Te c h n i c a l D a t a * Sensor output will open at 10 0-200 psi (0.68 MP a, 6.89 bar). Suction, Gravity Pressure Fed Bo x Lubricator Pump or Shaft Rota tion Alarm Pump Maximum W orking Pressure US Metric All 3/16” Piston Models 7500 psi 51.7 MP a, 517 bar All 1/4” Piston Models 6000 psi 41.4 MP a, 414 bar All 3/8” ...

  • Graco 24J393 - page 14

    Technica l Data 14 3A2257C Pump Dimensions Dimension Inches mm A 3.10 76.20 B 1.97 50.04 C 0.50 12.70 D Pump Min. 2.58 Pump Max. 3.18 Pump Min. 65.53 Pump Max.78.23 E5 . 3 7 1 3 6 . 4 0 F Min. 4.14 Max 4.90 Min. 105.20 Max 124.50 G 1.50 38.10 H 0.50 12.70 J 0.50 12.70 K 0.39 9.90 L 0.92 23.37 M 0.28 7.11 N 5.40 13 7.20 P 3.85 97.79 R 10.13 257.18 K ...

  • Graco 24J393 - page 15

    Technical Data 3A2257C 15 Gravity Fed Pressure Fe d Inlet P A Outlet C D Outlet Inlet A B C D ...

  • Graco 24J393 - page 16

    Technica l Data 16 3A2257C Suction Fed Outlet C D A P N Inlet ...

  • Graco 24J393 - page 17

    Technical Data 3A2257C 17 Alarm Pump C D P N Inlet R Retur n to Reser v oir 1/4 NPT Sensor Output ...

  • Graco 24J393 - page 18

    All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts. Original instructions. This manua l contains English. MM 3A2257 Graco Headquarters: Minneap ...

Производитель Graco Категория Heat Pump

Документы, которые мы получаем от производителя устройства Graco 24J393 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Graco
- инструкции обслуживания 24J393
- паспорта изделия Graco
- информационные брошюры
- энергетические этикетки Graco 24J393
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Graco 24J393.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Graco 24J393, инструкции обслуживания, короткие инструкции или инструкции пользователя Graco 24J393. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Graco 24J393.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Graco 24J393, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Graco 24J393 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Graco 24J393.

Полная инструкция обслуживания Graco, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Graco 24J393 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Graco 24J393, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Graco 24J393, которое найдем в данном документе
3. Советы по использованию основных функций устройства Graco 24J393 - которые должны облегчить нам первые шаги во время использования Graco 24J393
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Graco 24J393
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Graco 24J393 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Graco 24J393?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Graco 24J393, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Graco 24J393 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)