Инструкция обслуживания Napoleon Fireplaces Arlington GDS20N

28 страниц 1.85 mb
Скачать

Перейти на страницу of 28

Summary
  • Napoleon Fireplaces Arlington GDS20N - page 1

    1 W415-0496 / B / 08.10.05 W415-0496 / B / 08.10.05 ...

  • Napoleon Fireplaces Arlington GDS20N - page 2

    2 W415-0496 / B / 08.10.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS ...

  • Napoleon Fireplaces Arlington GDS20N - page 3

    3 W415-0496 / B / 08.10.05 WARNING • The sto ve is a vented g as-fi r ed hea ter . Do not b urn wood or other materials in this sto ve . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the stove is h ...

  • Napoleon Fireplaces Arlington GDS20N - page 4

    4 W415-0496 / B / 08.10.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired ...

  • Napoleon Fireplaces Arlington GDS20N - page 5

    5 W415-0496 / B / 08.10.05 Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. This appliance is only for use with the type of gas indicated on the rating plate . This appliance is not convertible for use with other gases, unless a certified kit is used. Do not use abrasive cleaners to clean the ...

  • Napoleon Fireplaces Arlington GDS20N - page 6

    6 W415-0496 / B / 08.10.05 MAINT AIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP .......................................48" HORIZONT AL VENT SIDES AND BOTTOM ............................. ...

  • Napoleon Fireplaces Arlington GDS20N - page 7

    7 W415-0496 / B / 08.10.05 BLO WER INST ALLA TION Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower . 3. Connect the black blower wire to the black wire coming from below the unit. 4. Insert the clip ...

  • Napoleon Fireplaces Arlington GDS20N - page 8

    8 W415-0496 / B / 08.10.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended t o use a heat shield and to maximize the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 requires a minimum 18 inches clear ance from an inside corn ...

  • Napoleon Fireplaces Arlington GDS20N - page 9

    9 W415-0496 / B / 08.10.05 Use only Wolf S teel, Simpson Dura-V ent, Selkirk Direct T emp or American Met al Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed us ...

  • Napoleon Fireplaces Arlington GDS20N - page 10

    10 W415-0496 / B / 08.10.05 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated. FIGURES 3 a-c FIGURE 4 TYPICAL VE ...

  • Napoleon Fireplaces Arlington GDS20N - page 11

    11 W415-0496 / B / 08.10.05 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) for the following symbols used in the venting calcula- tions and examples are: > - greater tha ...

  • Napoleon Fireplaces Arlington GDS20N - page 12

    12 W415-0496 / B / 08.10.05 V 1 HORIZONT AL TERMINA TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE IN ...

  • Napoleon Fireplaces Arlington GDS20N - page 13

    13 W415-0496 / B / 08.10.05 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Napoleon Fireplaces Arlington GDS20N - page 14

    14 W415-0496 / B / 08.10.05 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 f eet when (H T ) > (V T ) Simple venting configurations See graph to determine the required vertical rise V T for the required ho ...

  • Napoleon Fireplaces Arlington GDS20N - page 15

    15 W415-0496 / B / 08.10.05 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN. 1. Assemble the shield to ...

  • Napoleon Fireplaces Arlington GDS20N - page 16

    16 W415-0496 / B / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24 . Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run. Use supports or equivalent non-combustible strappin ...

  • Napoleon Fireplaces Arlington GDS20N - page 17

    17 W415-0496 / B / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flex- ible liner to the stove. Secure with 3 screws and flat wash- ers. Seal the joint and screw holes using high tempera- ture sealant. 3. Run a bead of high tem- perature sealant Mill Pac aro ...

  • Napoleon Fireplaces Arlington GDS20N - page 18

    18 W415-0496 / B / 08.10.05 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. FINISHING GLASS DOOR INST ALLA TION AND REMO V AL CAST FRONT INST ALLA TION AND REMO V AL Note: It is not ...

  • Napoleon Fireplaces Arlington GDS20N - page 19

    19 W415-0496 / B / 08.10.05 LOG PLACEMENT LOGO PLACEMENT Remove the backing from the the logo and position onto the control door as shown. It is not necessary to rem ove the cast fr ont, however , this will make for a more simple log installation. In order to assemble the log set, the door must be removed, see Cast Front / Glass Door Removal in the ...

  • Napoleon Fireplaces Arlington GDS20N - page 20

    20 W415-0496 / B / 08.10.05 Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door . The on-off switch is located on the back of the unit at the top right corner on model GDS20. When lit for the first time, the fireplace will emit a slight odour for a few hour s . This is a normal ...

  • Napoleon Fireplaces Arlington GDS20N - page 21

    21 W415-0496 / B / 08.10.05 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . FIGURE 34 FIGURE 35 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 36 ADJUSTMENTS PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT TURN OFF THE GAS AND UNPL UG ELECTRICAL POWER BEFORE SE ...

  • Napoleon Fireplaces Arlington GDS20N - page 22

    22 W415-0496 / B / 08.10.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor . When ordering replacement parts always give the fol- lowing information: 1. M ODEL & S ERIAL N UMBER OF FIREPLACE 2. I NST ALLA TION DA TE OF FIREP ...

  • Napoleon Fireplaces Arlington GDS20N - page 23

    23 W415-0496 / B / 08.10.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. ...

  • Napoleon Fireplaces Arlington GDS20N - page 24

    24 W415-0496 / B / 08.10.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. No spark a ...

  • Napoleon Fireplaces Arlington GDS20N - page 25

    25 W415-0496 / B / 08.10.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection. - replace thermocouple. - replace valve. Exhaust fume ...

  • Napoleon Fireplaces Arlington GDS20N - page 26

    26 W415-0496 / B / 08.10.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name ...

  • Napoleon Fireplaces Arlington GDS20N - page 27

    27 W415-0496 / B / 08.10.05 NO TES ...

  • Napoleon Fireplaces Arlington GDS20N - page 28

    28 W415-0496 / B / 08.10.05 NO TES ...

Производитель Napoleon Fireplaces Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Napoleon Fireplaces Arlington GDS20N мы можем разделить на несколько групп. Это в частности:
- технические чертежи Napoleon Fireplaces
- инструкции обслуживания Arlington GDS20N
- паспорта изделия Napoleon Fireplaces
- информационные брошюры
- энергетические этикетки Napoleon Fireplaces Arlington GDS20N
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Napoleon Fireplaces Arlington GDS20N.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Napoleon Fireplaces Arlington GDS20N, инструкции обслуживания, короткие инструкции или инструкции пользователя Napoleon Fireplaces Arlington GDS20N. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Napoleon Fireplaces Arlington GDS20N.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Napoleon Fireplaces Arlington GDS20N, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Napoleon Fireplaces Arlington GDS20N пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Napoleon Fireplaces Arlington GDS20N.

Полная инструкция обслуживания Napoleon Fireplaces, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Napoleon Fireplaces Arlington GDS20N - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Napoleon Fireplaces Arlington GDS20N, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Napoleon Fireplaces Arlington GDS20N, которое найдем в данном документе
3. Советы по использованию основных функций устройства Napoleon Fireplaces Arlington GDS20N - которые должны облегчить нам первые шаги во время использования Napoleon Fireplaces Arlington GDS20N
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Napoleon Fireplaces Arlington GDS20N
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Napoleon Fireplaces Arlington GDS20N в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Napoleon Fireplaces Arlington GDS20N?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Napoleon Fireplaces Arlington GDS20N, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Napoleon Fireplaces Arlington GDS20N со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)