    Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 2004-2010 Goodman Manufacturing Company , L.P . C US ® A TUF/ARUF/ARPF/ADPF/ASPF IO-355E 08/10 RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Ins ...

  • Goodman ADPF - page 2

    2 Import ant Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk ...

  • Goodman ADPF - page 3

    3 T o pre ve n t t he r is k of pr op e rt y dam age , per s on al injury , o r death, do not store comb ustible m aterials or use gasoline or other flammab le liquids or vapo rs in the vi c i n ity o f th i s un it. CARBON MONOX IDE POISO NING HAZ AR D - Special W a rning for Instal la tio n of Fur nace or A i r Handling Units i n Encl os ed Areas ...

  • Goodman ADPF - page 4

    4 Pre-Inst allation Instructions Carefully read all instructions for the installation prior to in- stalling product. Make sure each step or procedure is under- stood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need t ...

  • Goodman ADPF - page 5

    5 3568 1 0 1 5 2 0 2 1 600 16 25 32 37 800 12 19 24 38 38 1000 10 15 19 22 30 46 1 2 0 0 8 1 31 61 92 53 85 15 6 1 4 0 0 7 1 11 41 62 23 34 34 8 1600 6 9 12 14 19 28 38 42 1800 5 8 11 12 17 25 34 37 2000 5 8 10 11 15 23 30 34 CFM HEAT KIT NOMIN AL kW Table 4 208/1/60 Supply Voltage - Temperature Rise Table °F NOTE: For installations not indicated ...

  • Goodman ADPF - page 6

    6 Maximum Overcurrent Protection (MOP) Every installation must include an NEC (USA) or CEC (Canada) approved overcurrent protection device. Also, check with local or state codes for any special regional re- quirements. Protection can be in the form of fusing or HACR style circuit breakers. The Series and Rating Plate can be used as a guide for sele ...

  • Goodman ADPF - page 7

    7 2. After the gas has escaped, remove the nut and discard the black or brass cap. 3. Remove the check piston to verify it is correct and then replace the piston. See piston kit chart in instructions. 4. Use a tube cutter to remove the spin closure on the suction line. 5. Remove the tailpiece clamped to the exterior and slide the 13/16 nut into pla ...

  • Goodman ADPF - page 8

    8 3” F L A T IN S ULA TI O N RET AI NER (BOTH SID ES) Figure 4 To complete the conversion, slide the evaporator coil into the chassis and attach the three (3) access panels. (Figure 5). WRA PPER INSU LA T ION JAC KET ZEE C OIL SUPPORT WRAPPER STI FF ENE R DRAIN P AN INSUL A TION KIT BLOWER A SSEMBL Y Figure 5 NOTE: When converted to downflow posi ...

  • Goodman ADPF - page 9

    9 drain line located inside the building. Use Armaflex® or similar material. A Secondary Condensate Drain Connection has been pro- vided for areas where the building codes require it. Pitch the drain line 1/4" per foot to provide free drainage. Insulate drain lines located inside the building to prevent sweating. Install a condensate trap to ...

  • Goodman ADPF - page 10

    10 0. 1" 0. 2" 0. 3" 0. 4" 0.5 " High 1155 1090 10 25 950 895 A RUF 172916 M ed. 94 0 890 860 81 5 755 Low 695 665 650 610 55 0 High 1155 1090 10 25 950 895 A RUF 182416 M ed. 94 0 890 860 81 5 755 Low 695 665 650 610 55 0 High 1135 1085 10 25 965 915 A RUF 193116 M ed. 86 0 825 780 75 0 680 Low 600 570 545 500 46 5 High 13 ...

  • Goodman ADPF - page 11

    11 thermostat as shown in Figures 10 and 11 . Goodman® part number CHT18-60 is a single-stage cool and single-stage heat thermostat. Goodman® part number HPT18-60 is a single-stage cool, two-stage heat pump thermostat. The first stage is heat pump heating and the second stage is optional electric heat. If additional features are desired, such as ...

  • Goodman ADPF - page 12

    12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G ROOM T HERM OST A T WY GR #18 GA ...

  • Goodman ADPF - page 13

    13 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. C W2 OYR YOC GR E W2 TYP ICAL H/ ...

  • Goodman ADPF - page 14

    14 ASPF THERMOST A T CONNECTIONS The following composite wiring diagrams detail various configurations in which the ASPF air handlers can be used. Ex- amples include single-stage cooling and heat pump with single or two-stage electric heating. All these configurations can be applied with convenient connections to outdoor thermostat applications. Th ...

  • Goodman ADPF - page 15

    15 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. YG W W2 R COOLIN G UNIT WITH OPT ...

  • Goodman ADPF - page 16

    16 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G G C R HEA T PUMP UNIT WITH OPTIO ...

  • Goodman ADPF - page 17

    17 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 12 0/24 0V A C TS T A T OP TI ON ...

  • Goodman ADPF - page 18

    18 THIS P AGE LEFT INTENTIONALL Y BLANK ...

  • Goodman ADPF - page 19

    19 THIS P AGE LEFT INTENTIONALL Y BLANK ...

  • Goodman ADPF - page 20

    20 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 2004-2010 Goodman Manufacturing Company , L.P . ...

Производитель Goodman Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Goodman ADPF мы можем разделить на несколько групп. Это в частности:
- технические чертежи Goodman
- инструкции обслуживания ADPF
- паспорта изделия Goodman
- информационные брошюры
- энергетические этикетки Goodman ADPF
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Goodman ADPF.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Goodman ADPF, инструкции обслуживания, короткие инструкции или инструкции пользователя Goodman ADPF. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Goodman ADPF.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Goodman ADPF, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Goodman ADPF пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Goodman ADPF.

Полная инструкция обслуживания Goodman, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Goodman ADPF - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Goodman ADPF, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Goodman ADPF, которое найдем в данном документе
3. Советы по использованию основных функций устройства Goodman ADPF - которые должны облегчить нам первые шаги во время использования Goodman ADPF
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Goodman ADPF
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Goodman ADPF в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Goodman ADPF?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Goodman ADPF, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Goodman ADPF со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)