    I nstallation & I nstruction Manual G uar dian ® Easytrack S ystem 3-P ost Assembly M odel 93000 ...

  • Sunrise Medical 93000 - page 2

    T ABLE OF CONTENTS Intr oducti on .......................................................................................... 2 Important Safegu ards .............................................................................. 3 Requirem ents ......................................................................................... 4 Befor e Y ou B ...

  • Sunrise Medical 93000 - page 3

    3-Post System IMPORT ANT S AFEGU ARDS Do not operate this equipment without fir st reading and understanding this manual. Should you be unable to under stand the warnings, cautions and instructions , contact our technical support or your local dealer befor e attempting to use this equipment– otherwise injury or damage may result. Important inform ...

  • Sunrise Medical 93000 - page 4

    REQUIREMENTS Failur e to meet requirements listed belo w could result in serious bodily harm. Ceiling Requirements • Install to a rigid ceiling (must have a framework above it). • Must have a maximum of 24" (610mm) between the trusses in the ceiling. • Ceiling must be made of wood or 1/2"(12.7mm) sheet rock or thicker. • Ensure ce ...

  • Sunrise Medical 93000 - page 5

    3-Post System BEFORE YOU BEGIN Read "Requirements" and “ Important Safeguards ” bef ore attempting to assemble the Easytr ack System. 1. Survey the room where you plan to install the Easytrack System. Make sure the room meets all the specifi- cations outlined in "Requirements". 2. Use the measurements below to determine the ...

  • Sunrise Medical 93000 - page 6

    EASYTRA CK 3-POST SYSTEM KIT CONTENTS & P ART NUMBERS (Figure 6) Description P art # Qty 1 Pivoting e xtendable rail w/stan dard tr olley 900-0850 1 2 Extend able rail w/swivel trolley 900-0800 1 3 Pivot post ?? 1 4 P ost top for pivot post N/A 4 5 Stand ard post 900-0500 2 6 Blue locking han dle N/A 3 7 Round blue cap 900-0720 3 8 Allen key 90 ...

  • Sunrise Medical 93000 - page 7

    3-Post System 5. T ake the pivot post out o f the box and th e post top for pivot post. Insert th e post top into the post until it sn aps into place (Figur e 9). 6. T ake top plate and clip-on level out of th e box. Place the clip-on level onto th e post at approxim ately waist hei ght (Figur e 10). 7. Place the post onto th e foot plate and pr es ...

  • Sunrise Medical 93000 - page 8

    12. Once th e bubble is in the center o f the clip-on level, con tinue to tigh t- en ONL Y un til the red zon e at the top of th e post is no long er visible (Figur es 16-A & B). Red zone must not be visible for the post to be safely secured. o not ov er-tighten the post. Tighten only until red zone disap- pears . Over-tightening post may cause ...

  • Sunrise Medical 93000 - page 9

    3-Post System b . Find the en d stopper from insi de the top o f the rail. Th e top por- tion is th e section without th e small tr olley in it (Figure 20). c. U sing the Allen k ey provid ed, loosen the stopper in th e upper portion o f the rail an d slide it out of th e rail (Figur e 21). 20 . Place the end o f the rail with th e hooks on to the ...

  • Sunrise Medical 93000 - page 10

    BEFORE USING THE EASYTRA CK SYSTEM GO THROUGH THE FOLLOWING CHECKLIST : ✓ Mak e sure the r ed zone on top of all posts ar e not visible . ✓ Mak e sure the posts ar e straigh t. (Did you use the clip-on level?) ✓ Mak e sure the r ail is locked into place (see step 15) an d that it looks level. ✓ Mak e sure the stopper is sn ug (see step 22b) ...

  • Sunrise Medical 93000 - page 11

    3-Post System NOTE – M etal pins cannot be pressed in wh en there is d ownward pressur e on them. Pressur e must be released to pr ess in pins. 14. Remove th e post from the f oot plate by stepping on both sid es with your feet and pulling th e post up. 15. Place all pieces in to a box or bag to protect th em from dust an d/or damag e. 16. Repeat ...

  • Sunrise Medical 93000 - page 12

    Upon receipt o f your Easytrack System: 1. Make sur e you received all componen ts listed in Figure 6. 2. Inspect all parts for possible d amage in tr ansit. 3. Ensure all compon ents are in workin g order . 4. Arrang e for repair/r eplacement o f any faulty parts . 5. Keep a log of an y repair/replacem ent requir ed. Befor e each use of the Easytr ...

  • Sunrise Medical 93000 - page 13

    3-Post System T roubleshooting 13 TROUBLESHOOTING PROBLEM 1. T rolley moves substanti ally on its own when the Easytr ack System is fully assembled. 2. Extend ed rail comes completely apart durin g assembly . 3. Not able to push pin to assemble/disassem- ble post. 4. Not able to ti ghten post enough to hid e red zone . 5. P osts do not appear stabl ...

  • Sunrise Medical 93000 - page 14

    EASYTRA CK PRODUCTS & ACCESSORIES Easytrack 2-P ost System ........................................................................... 92000 Easytrack 4-P ost System ........................................................................... 94000 Easytrack 2-P ost with T ub Bracket ............................................................. ...

  • Sunrise Medical 93000 - page 15

    3-Post System W ARRANTY This warran ty is extend ed only to the origin al purchaser/user of Sunrise pr oducts. Sunrise Medi cal Inc. warr ants its prod ucts to be free fr om defects in material un der norm al use and servi ce and will, within the peri ods stated below , from th e date of pur chase. If within such warr anty period an y such prod uct ...

  • Sunrise Medical 93000 - page 16

    Distributed by: Sunrise Medical 7477 East Dry Creek P arkway Longm ont, Colorad o 80503 (800) 333-4000 In Canad a (800) 263-3390 Printed in Can ada © 2001 Sunrise Medi cal 10.01 900-0610 Re v . A ...

Производитель Sunrise Medical Категория Indoor Furnishings

Документы, которые мы получаем от производителя устройства Sunrise Medical 93000 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Sunrise Medical
- инструкции обслуживания 93000
- паспорта изделия Sunrise Medical
- информационные брошюры
- энергетические этикетки Sunrise Medical 93000
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Sunrise Medical 93000.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Sunrise Medical 93000, инструкции обслуживания, короткие инструкции или инструкции пользователя Sunrise Medical 93000. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Sunrise Medical 93000.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Sunrise Medical 93000, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Sunrise Medical 93000 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Sunrise Medical 93000.

Полная инструкция обслуживания Sunrise Medical, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Sunrise Medical 93000 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Sunrise Medical 93000, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Sunrise Medical 93000, которое найдем в данном документе
3. Советы по использованию основных функций устройства Sunrise Medical 93000 - которые должны облегчить нам первые шаги во время использования Sunrise Medical 93000
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Sunrise Medical 93000
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Sunrise Medical 93000 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Sunrise Medical 93000?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Sunrise Medical 93000, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Sunrise Medical 93000 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)