  • Emerson CF654WW00 - page 1

    Part No. F40BP73360000 Form No. BP7336 U.L. Model No.: CF654 READ AND SA VE THESE INSTRUCTIONS Model No. CF654A W00 CF654ORB00 CF654WB00 CF654WW00 SEA BREEZE Net Weight: 18.7 Lbs. 52” Ceiling Fan Owner's Manual ENERGY ST AR ...

  • Emerson CF654WW00 - page 2

    2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally ...

  • Emerson CF654WW00 - page 3

    T ools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Three wire connectors (supplied). MA TERIALS Wiring, electrical box and box connectors must be of type required by the local code. The minimum wiring would be a 3-conductor (2-wire with ground) of follow- ing sizes: Installed Wire Length Wire Size A.W.G. Up to ...

  • Emerson CF654WW00 - page 4

    How to Put Y our Ceiling Fan T ogether 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5. 2. Unscrew the two upper setscrews (Figure 2) until they cle ...

  • Emerson CF654WW00 - page 5

    Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds. If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing l ...

  • Emerson CF654WW00 - page 6

    1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 8). A T LEAST 7' CEILING FLOOR How to Hang Y our Ceiling Fan Figure 7 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 8 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 9 2. Carefully lift t ...

  • Emerson CF654WW00 - page 7

    3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 11). 5. Secure the ceiling cover in place by sliding lockwash- ers over the threaded studs and installing the two knurled knobs (suppl ...

  • Emerson CF654WW00 - page 8

    1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. 4. If airflow is desired in opposite direction, turn your ...

  • Emerson CF654WW00 - page 9

    T rouble Shooting W ARNING: FOR YOUR OWN SAFETY TURN OFF POWER A T FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR F AN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Reversing switch in neutral position. 1. Make sure reversing switch position is all the way to one side. 2. Fuse or circuit breaker blown. 2. Check main a ...

  • Emerson CF654WW00 - page 10

    2 1 1 9 9 9 5 9 9 9 8 9 9 9 3 6 7 9 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER The model number of your Fan will be found on a label attached to th ...

  • Emerson CF654WW00 - page 11

    Repair Parts Listing Key Service Part No. N o. Description CF654WW01 CF654WB00 CF654AW00 CF654ORB00 1 Hanger Assembly 761655 761655-20 761655-21 761655-32 2 Ceiling Cover 760169 760169-30 760169-32 760169-41 3 Blade Set (5) 762004 762004-5 762004-4 762004-6 4 Flange Set (5) 763116-WW 763116-WB 763116-AW 763116-ORB 5 Switch Housing Cover 763117-WW 7 ...

  • Emerson CF654WW00 - page 12

    Form No. BP7336-1 Part No. F40BP73360001 Printed in China 11/08 Air Comfort Products DIVISION OF Emerson Electric Co. 8100 W. Florissant ¥ St. Louis, MO 63136 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and material ...

Производитель Emerson Категория Fan

Документы, которые мы получаем от производителя устройства Emerson CF654WW00 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Emerson
- инструкции обслуживания CF654WW00
- паспорта изделия Emerson
- информационные брошюры
- энергетические этикетки Emerson CF654WW00
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Emerson CF654WW00.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Emerson CF654WW00, инструкции обслуживания, короткие инструкции или инструкции пользователя Emerson CF654WW00. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Emerson CF654WW00.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Emerson CF654WW00, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Emerson CF654WW00 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Emerson CF654WW00.

Полная инструкция обслуживания Emerson, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Emerson CF654WW00 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Emerson CF654WW00, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Emerson CF654WW00, которое найдем в данном документе
3. Советы по использованию основных функций устройства Emerson CF654WW00 - которые должны облегчить нам первые шаги во время использования Emerson CF654WW00
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Emerson CF654WW00
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Emerson CF654WW00 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Emerson CF654WW00?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Emerson CF654WW00, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Emerson CF654WW00 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)