    SCAN A10 INSTRUCTIONS FOR INSTALLATION AND USE Te s t e d & Li s t e d b y B e av er t o n O r e gon U S A O MN I - Te s t La b ora t o ri e s , I n c . Save these instructions February 2003 KROG IVERSEN & CO. A/S - 5492 VISSENBJERG - DENMARK Table of Contents: ...

  • SCAN A10 - page 2

    2 1. INTRODUCTION.................................. ............................................. ................................. ...... ....................................... 3 Safety and environment al testing. ..................... ................................................... ...................... .................................... ...

  • SCAN A10 - page 3

    3 We welcome you as a new owner of a SCAN A10 wood-burning stove. In purchasing a SCAN stove you have joined the growing ranks of concerned in dividuals whose selection of energy systems reflects both a conce rn for the environment and aest hetics. The SCAN stove is one of the finest home wood stoves in the world over. This manual will explain the ...

  • SCAN A10 - page 4

    4 SAFETY PRECAUTIONS KEEP THE START DEVI CE CLOSED DURING FIRING I N THIS STOVE. THE START DEVICE MAY BE OPENED FOR A MAXIMUM OF 5 MINUTES DURING START-UP. USE A METAL CONTAINER WI TH A TIGHT FITTING LID TO DISPOSE OF ASHES. NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMI LAR LIQUIDS TO START OR “FRESHEN ...

  • SCAN A10 - page 5

    5 2. INSTALLATION Precaution If your SCAN A10 stove is no t properly installed, operated and main tained, a house fire may result. For your safety, follow all installation, ope ration and maintenance directions. Contact your local building officials about restrictions and installation requirements in your area. Pre Installation Check List: Before y ...

  • SCAN A10 - page 6

    6 NOTE: The clearances expressed in inches are those approved for installation in the United States. The clearances in expressed in millimeters are th ose approved for installations in Canada. Different test standards for the respective co untries may result in differences in the clearan ce requirements. The Floor One of the main necessary precauti ...

  • SCAN A10 - page 7

    7 Corner installation Floor protection for Corner Installation A B C D USA 16" 4” 69 5/8” 98 ½” Canada 457 1840 2602 In a rear vent installation the floor protection must also extend under th e stovepipe a minimum of 2” (50mm) beyond eithe r side of the pipe. Ceiling H eight: Do not install in an alcove or confined space and do not in ...

  • SCAN A10 - page 8

    8 Combustible Wall Clearance for Top Vent Installation If the stove is to be placed at side and back walls of combustible materials the following clearances must be kept Parallel i nstallation Corner install ation Parallel installation Connector pipe A B C D USA Single wall 13” 9.5” 21” 11” Canada Single wall 406 317 533 279 Corner installa ...

  • SCAN A10 - page 9

    9 Combustible Wall Cl earance for Rear Vent Installation If the stove is to be placed at side and back walls of combustible materials the following clearances must be kept: Refer to the manufac turer’s instructions concerning installation of lis ted single wall connector pipe, wall thimble and chimney Alcove Installation Requirements: Whenever th ...

  • SCAN A10 - page 10

    10 Mobile Ho me Installation : US only In addition to standard installation the following requirements are mandatory for installation in a mobile home. The stove must be permanently bolted to the floor of the mobile home using the floor screws provided. Note: If the composition of the manufactured (m obile) home floor is of light particleboard cons ...

  • SCAN A10 - page 11

    11 Outside air requirements Required for mobile home and in certain localities (Check with building o fficials) Outside air must not be drawn from an enclosed space (garage or o ther unventilated spaces) When using o utside air, find a location where the chimney and outside air hole do not interfere with str uctural m embers of the hom e. Connect a ...

  • SCAN A10 - page 12

    12 Chimney Installa tion: Do not connect this unit to a chimney flue servi ng another appliance. Do not connect to any air distribution duct or system . The SCAN A10 stove is listed for in stallation as a ve rtically top or rear vented stove using a listed class A (UL103HT) for Canada (CAN/ULC-S629) fa ctory built chimney exiting through the ceilin ...

  • SCAN A10 - page 13

    13 Chimney Connection The chimney connector is ether a sin gle or doubl e walled pipe, depending on the type of installation, used to conne ct the stove to the chimney. For use with the SCAN woodstoves the c himney connector MUST be 6” in d iameter, with a mi nimum thickness of 24 gauge black steel or 26 gauge blued steel. Aluminium and galvanize ...

  • SCAN A10 - page 14

    14 Rear Vent Installation For venting into a masonry or a bac k standing steel chimney through the top vent the top horizontal portion of a single wall connector pipe ca n be located not closer than 18” below a combustib le ceiling. From the factory the stove is pre pared for top moun ting of the flue collar, but all SCAN stoves have an optional ...

  • SCAN A10 - page 15

    15 Combustible Wall Chi mney Connector Pass-Throughs. Method A. 12” (304.8 mm) Cleara nce to Combustible Wall Member : Using a minimum thickne ss 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum w all th ickness clay line r, construct a wall pa ss-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) ...

  • SCAN A10 - page 16

    16 NOTES: 1. Connectors to a masonry chimney, ex cepting method B, shall extend in one continuous section through the wall pass-th rough system and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. Chimney heig ...

  • SCAN A10 - page 17

    17 3. INSTRUCTIONS FOR USE Ash Drawer The ash drawer located behind the fuel door is designed to make cleaning easier by c ontaining the ashes in a removable drawer Ash Grate Above the ash drawer, locat ed in the floor of the firebox is a rotating ash grate to facilitate transferring ashes from the fireb ox into the ash drawer. To operate this grat ...

  • SCAN A10 - page 18

    18 Ceramic Packing Cord These stoves are equipped with a ceramic packing co rd to ensure the tightness of the doors and the glasses. This packin g cord is a wearing part an d must be changed from time to time. Please con sult your authorized dealer in this case. Protected Wall Reduced Clearances Local codes in some areas will allow reduced clearanc ...

  • SCAN A10 - page 19

    19 Starting a Fire: Do not elevate the fire. Build fire directly on the hearth inside the stove; do not build fire above or in front of the log retainer. To start a fire: Pull the start device and air intake control to fully open. In addition, to help with the start-up, you may also leave the fuel doo r slightly ajar. Use a sm all amount of fire st ...

  • SCAN A10 - page 20

    20 Removing Baffle for Cleaning Be sure the fire is out and the stove is cold befor e removing baffle plate. Be cautions with handling the plates because the plates are made of a delicate material; which easily broke if not handle with care. Removal of the lower plate: lift the plate (pos 1) u p from the supporting pi ns (pos 4) and take the pins o ...

  • SCAN A10 - page 21

    21 Air Tube removal: Remove the screw (pos.1) on the left air tube collar (pos.3). Slide the air tube (pos.2) to the right, swing it down and remove it. Replacement Part List SCAN A10 Caution: Use only original SCAN A10 replacement part. Do not use subs titute materials. Replacement part Part # Glass panel for the door 57811011 Gasket for the glass ...

  • SCAN A10 - page 22

    22 Creosote Formation and the Need for Removal When wood is burned slowly it produces tar and other organic vapors, wh ich combine with expelled moisture to form creosote. The creos ote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote res idue accum ulates in the flue lining. When ignited this creoso ...

  • SCAN A10 - page 23

    23 6. TROUBLESHOOTING Smoke: - Insufficient chimney draught! - Check if the chimney has the right dimension. - Check if the smoke pipe or chimney is blocked. - Check if the chimney has the right height compared to the surroundings. - Wood with excessive moisture content. The wood burns too fast: - Are the air valves adjusted correctly according to ...

  • SCAN A10 - page 24

    24 7. WARRANTY CONDITIONS FOR SCAN WOOD BURNING PRODUCTS All SCAN wood stoves, inserts and fireplaces are subject to a s trict quality control, before they are shipped to the customer and end user. However, s hould an error occur, we back all SCAN wood burning stoves, inserts, and fireplaces with an extensive five years limited warranty. The warran ...

  • SCAN A10 - page 25

    25 8. EPA Sticker ...

Производитель SCAN Категория Stove

Документы, которые мы получаем от производителя устройства SCAN A10 мы можем разделить на несколько групп. Это в частности:
- технические чертежи SCAN
- инструкции обслуживания A10
- паспорта изделия SCAN
- информационные брошюры
- энергетические этикетки SCAN A10
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания SCAN A10.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа SCAN A10, инструкции обслуживания, короткие инструкции или инструкции пользователя SCAN A10. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия SCAN A10.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства SCAN A10, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании SCAN A10 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей SCAN A10.

Полная инструкция обслуживания SCAN, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией SCAN A10 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания SCAN A10, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся SCAN A10, которое найдем в данном документе
3. Советы по использованию основных функций устройства SCAN A10 - которые должны облегчить нам первые шаги во время использования SCAN A10
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем SCAN A10
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра SCAN A10 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся SCAN A10?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с SCAN A10, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с SCAN A10 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)