    These operating instructions can be a helpful guide to assist you in using your new ISDN telecommunications equip - ment (PABX system). No matter whether your elmeg PABX is for your work or for your personal use, ease of use and enjoyment while using the phone are guaranteed. Please take a little time to try out the functions that are packed into t ...

  • Teldat Elmeg ICT46 - page 3

    Table of contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Loss of power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Teldat Elmeg ICT46 - page 4

    Block dialing (Austria) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Hotel functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Wake-up call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 MWI Activa ...

  • Teldat Elmeg ICT46 - page 5

    Description The PABX is an ISDN telecommunications system (PABX) for interfacing with the Euro ISDN (DSSI) protocol. The PABX is provided with external ISDN connections, which are configured for interfacing to the ISDN connections of the network service provider. Depending on the type of PABX, ISDN connections can be set as required as internal or ...

  • Teldat Elmeg ICT46 - page 6

    · Do not use the unit in excessively humid rooms or hazardous locations. · Only open those sections of the device specified in the assembly / operating instructions. · Do not touch plug connectors with pointed, metal, or moist objects. · If you do not permanently mount the device or any accessories, be sure to place it/them on a non-slip surfac ...

  • Teldat Elmeg ICT46 - page 7

    · Dispose of the exhausted battery pack according to local rules and regulations. Recycle! Do not expose battery cells to open fire. Radio devices (e.g. DECT, Bluetooth) · It is possible in some cases that medical devices are affected by powered-up radio devices. Please comply with local rules and regulations concerning DECT devices. · Do not op ...

  • Teldat Elmeg ICT46 - page 8

    Operation Not all of the features described here may be implemented in the standard ISDN connection supplied by your net - work service provider. Contact your service provider to determine which features come standard with your ISDN ac - cess and which ones you must apply for separately. If your phone is set for »Automatic line access« you must f ...

  • Teldat Elmeg ICT46 - page 9

    Specific trunk bundle selection b *8t or *8#t t g a Lift up handset Select trunk group ISDN, POTS (0...8) Select trunk group ISDN, POTS, SIP-Prov. (00...08), (10...19) Dial external number Conversation Making internal calls All phone calls, fax transmissions or data transmissions that take place between internal analog and ISDN terminal devices are ...

  • Teldat Elmeg ICT46 - page 10

    Automatic completion of call to busy subscriber or on no answer This function can only be used by telephones that permit suffix dialing. Automatic call completions from an inquiry call are not possible. Attention: External Completions of call to busy subscriber are deleted after a period defined by the exchange. Programming »Completion of call« f ...

  • Teldat Elmeg ICT46 - page 11

    Temporarily suppressing transmission of your own number Attention: This feature must be applied for at your network service provider. Transmission of the caller’s own number is suppressed using the following procedure with analog terminal devices. Please refer to the operating instructions for ISDN terminal devices on how to initiate this feature ...

  • Teldat Elmeg ICT46 - page 12

    bt g a Lift up handset Internal number for the voice announcement extension Voice announcement Terminate voice announcement Switching a voice announcement for all numbers (day / night) Attention: Day / Night switchable Announcements b *92* oder #92* q a Lift up handset Day Night Ack. signal Replace handset Announcement Refer to the operating instru ...

  • Teldat Elmeg ICT46 - page 13

    Room monitoring from external telephones You are located at an external telephone. Lift up the handset of the phone from which you wish to conduct room monitoring and dial the external number to which the service number for the PABX is assigned. If remote access has been enabled and is possible at this time you will hear the special dial tone of yo ...

  • Teldat Elmeg ICT46 - page 14

    (keypad-function »Net fixed«) b0 * oder #t a Lift up handset Dial line access digit Initiate keypad function Enter codes Replace handset Sending a fax from a multi-function terminal b *773 t l Lift up handset Enter code number for fax group 3 Dial the external number Direct dial-in Making telephone calls with activated direct dial-in bt Lift up h ...

  • Teldat Elmeg ICT46 - page 15

    t If you wish to speak to an external party, dial 0 first. If you hear a busy signal after dialing 0, either your telephone does not have proper authorization for an external call, or the line is busy. t Dial the number of the party you wish to reach. You will hear the ringing signal in your handset. The party will be called. The party being called ...

  • Teldat Elmeg ICT46 - page 16

    Refusing a waiting call g You are conducting a call. A second party calls you. You hear the call waiting signal. R0 Dial this code to refuse the waiting call. The caller can be switched to the waiting queue, or the call is established and the caller will hear the busy signal. Transferring the existing call using analog telephones If you hear the ca ...

  • Teldat Elmeg ICT46 - page 17

    (Explicit call transfer) Connecting Please note that ISDN terminal devices can only utilize the feature »Connect« via a special key or menu function. The following procedure applies only to analog telephones. g You are conducting a call with party 1. A further call is signaled, for example by call waiting. R2 Dial this code. Party 2 answers; you ...

  • Teldat Elmeg ICT46 - page 18

    t Dial the number of the party you wish to reach. You will hear the ringing signal in your handset. The party will be called. The party being called lifts up the handset of his/her phone. g You would like to include this party in the first call. R3 Dial this code. d Conduct your three-party conference call. d You would now like to exclude the party ...

  • Teldat Elmeg ICT46 - page 19

    Call modes (Day- / Night) Activating team call assignment for one team b* / #9 3 t q a Lift up handset Day / Night call mode Enter team number (00...39) Ack. signal Replace handset Switching team call assignment for all teams b* / # 93* q a Lift up handset Day / Night call mode Ack. signal Replace handset door terminal (door intercom device) - Swit ...

  • Teldat Elmeg ICT46 - page 20

    Activating the switching function for an internal subscriber b* / #9 1 q a Lift up handset Activate day mode / night mode Code Ack. signal Replace handset Follow me Setting up or deleting an internal Follow me b* / # 6 4 t#qa Lift up handset Set up / delete Follow me *1) Ack. signal Replace handset *1) Internal number whose calls are to be forwarde ...

  • Teldat Elmeg ICT46 - page 21

    Block dialing (Austria) b *55 0 or tt#g Lift up handset Line access digit *1) Call number *2) *1) If you’d rather use a specific external ISDN connection or bundle,s enter the corresponding code. *2) Begin dialing by pressing the key # . Only now is the call transferred to the exchange. Least Cost Routing (LCR) Please note that there are some pro ...

  • Teldat Elmeg ICT46 - page 22

    Hotel functions This PABX system comes equipped with extensive hotel functions. This function is used from the reception desk phone via the PABX system menu. Registering the hotel room status Dialing a numeric code from the room telephone makes it possible to register the current status of the room. This data collection can be analyzed and displaye ...

  • Teldat Elmeg ICT46 - page 23

    Door intercom device Making a door interphone call / Opening the door l bgR * 9 9 x Door intercom call Lift up handset Conversation via door intercom Code X1 / 2 / 3 / 4q a 1 = Door opener 1 2 = Door opener 2 3 = Door opener 3 4 = Door opener 4 Ack. signal Replace handset Activating the door opener b *99 1 / 2 / 3 / 4q a Lift up handset Code Door o ...

  • Teldat Elmeg ICT46 - page 24

    Confirm alarm call An alarm call can be confirmed locally at a telephone assigned to the alarm input. To confirm an external alarm call, you will need a dtmf-capable phone. l b *537 q a The alarm call is indi - cated Lift up handset Ack. signal Replace handset Switching contacts Attention: In the event of a loss of power and after a reset the switc ...

  • Teldat Elmeg ICT46 - page 25

    Call Through This action may only be performed from an external phone. b tqttg Lift up handset Select “Numbers in my phone system for call-through” 1) Enter PIN Dialing external destinati - on numbers 1) The configuration of the PABX system is decisive for this input (with or without PIN, with number recognition, or both). Dial authorization wi ...

  • Teldat Elmeg ICT46 - page 26

    Communication / Call charges The PABX generates a call data record for every external call. The call data records contain detailed information about the call. For ex.: Date and time, duration of the call, number of the called party, number of the calling party, type of connec - tion, communication costs and possible project numbers. Incoming calls ...

  • Teldat Elmeg ICT46 - page 27

    Telephone directory for the PABX, Follow me, direct dial-in, Day / Night (call modes) schalten, cost registration, hotel functions Attention: You can select the language of your display, provided the desired language has been configured using the telephone directory programmeme. Refer to the operating instructions of the system telephone being used ...

  • Teldat Elmeg ICT46 - page 28

    Service Configuration of system features using a telephone Various settings are protected by PIN1 in the PABX. In the default state, this PIN 1 is set to 0000. Write down your PIN 1 and keep it in a safe place, because if you forget or lose your PIN 1 you will no longer have access for configuring the PABX over a telephone. If you do forget your PI ...

  • Teldat Elmeg ICT46 - page 29

    Ending an active, incoming service link You can terminate a connection set up by the service center using the following procedure. b #792 q a Lift up handset Ack. signal Replace handset Enabling for remote service access You can release your PABX system for remote access by an external subscriber. Release for remote access of the PABX is effected f ...

  • Teldat Elmeg ICT46 - page 30

    Index A Accepting of calls . . . . . . . . . . . . . . . . . . . . . . 5 Accepting a waiting call . . . . . . . . . . . . . 11 Activating the LCR procedure . . . . . . . . . . 17 Alarm call . . . . . . . . . . . . . . . . . . . . . 19 Alarm call list . . . . . . . . . . . . . . . . . . . 19 Allocating project numbers . . . . . . . . . . . . 9 Annou ...

  • Teldat Elmeg ICT46 - page 31

    L Language . . . . . . . . . . . . . . . . . . . . . 23 Loss of power . . . . . . . . . . . . . . . . . . . . 3 M Making calls outside . . . . . . . . . . . . . . . . . . . . . . 4 Making Calls Internal . . . . . . . . . . . . . . . . . . . . . 5 Making outside calls . . . . . . . . . . . . . . . . 4 Making outside calls with direct exchange line a ...

  • Teldat Elmeg ICT46 - page 32

    Trunk group seizure . . . . . . . . . . . . . . . . 5 U Using system telephones . . . . . . . . . . . . . 23 V Voice announcement. . . . . . . . . . . . . . . . 7 W Waiting call accepting . . . . . . . . . . . . . . . . . . . . 11 Wake-up call . . . . . . . . . . . . . . . . . . . . 18 Index 28 ...

  • Teldat Elmeg ICT46 - page 33

    Index 29 ...

  • Teldat Elmeg ICT46 - page 34

    Configuration using a telephone (administrators) The following procedure must be performed one time at the beginning of configuration. b ** q ==== q Lift up handset Ack. signal Enter PIN 1 Ack. signal Change PIN 1 or PIN 2 911 or 912 t t q Change PIN 1 (4-place) Change PIN 2 (6-place) Enter new PIN Input new PIN (confirm) Ack. signal Configuring ca ...

  • Teldat Elmeg ICT46 - page 35

    Setting up call accounts 8 3 0 tt#q Code number Int. extension number amount (max. 6-place, with a fac - tor of 100) Ack. signal Deleting call accounts 830 t # q Code number Int. extension number Ack. signal Activating / deactivating an extension’s call account 890 t * / #q Code number Int. extension number Activate / Deactivate Ack. signal Activ ...

  • Teldat Elmeg ICT46 - page 36

    Configuration using a telephone (administrators) 32 ...

  • Teldat Elmeg ICT46 - page 37

    A ...

  • Teldat Elmeg ICT46 - page 38

    Funkwerk Enterprise Communications GmbH Südwestpark 94 D-90449 Nürnberg For information on support and service offerings please visit our Website at www.Funkwerk-ec.com where, you will find a Service / Support area Subject to modifications Ausgabe 4 / 010109 ...

Производитель Teldat Категория Intercom system

Документы, которые мы получаем от производителя устройства Teldat Elmeg ICT46 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Teldat
- инструкции обслуживания Elmeg ICT46
- паспорта изделия Teldat
- информационные брошюры
- энергетические этикетки Teldat Elmeg ICT46
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Teldat Elmeg ICT46.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Teldat Elmeg ICT46, инструкции обслуживания, короткие инструкции или инструкции пользователя Teldat Elmeg ICT46. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Teldat Elmeg ICT46.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Teldat Elmeg ICT46, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Teldat Elmeg ICT46 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Teldat Elmeg ICT46.

Полная инструкция обслуживания Teldat, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Teldat Elmeg ICT46 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Teldat Elmeg ICT46, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Teldat Elmeg ICT46, которое найдем в данном документе
3. Советы по использованию основных функций устройства Teldat Elmeg ICT46 - которые должны облегчить нам первые шаги во время использования Teldat Elmeg ICT46
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Teldat Elmeg ICT46
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Teldat Elmeg ICT46 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Teldat Elmeg ICT46?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Teldat Elmeg ICT46, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Teldat Elmeg ICT46 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)