    ICI3000P Inter-Check Point-Of-Sale Monitoring System Installation/Operation Manual C1043M-A (2/96) ® PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981 FAX (800) 289-9150 or (1-559) 292-3827 ...

  • Pelco C1043M-A - page 2

    TABLE OF CONTENTS Section Page 1.0 W ARNINGS ....................................................................................................................................... 1 2.0 SCOPE .............................................................................................................................................. 2 2.1 DESCRIPT ...

  • Pelco C1043M-A - page 3

    LIST OF ILLUSTRA TIONS Figur e Page 1 TYPICAL ICI3000P SYSTEM USED WITH ST AND-ALONE CAMERAS .............................................. 2 2 ICI3000P PAR TYLINE WIRING CONFIGURA TION .............................................................................. 4 3 DEF A UL TING INTER-CHECK SYSTEM. ............................................... ...

  • Pelco C1043M-A - page 4

    iv P elco Manual C1043M-A (2/96) (This page intentionally left blank.) ...

  • Pelco C1043M-A - page 5

    P elco Manual C1043M-A (2/96) 1 INSTALLATION/OPERATION MANUAL ICI3000P INTER-CHECK ® POINT-OF- SALE MONITORING SYSTEM Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying th ...

  • Pelco C1043M-A - page 6

    2 P elco Manual C1043M-A (2/96) 2.0 SCOPE The information contained within this manual covers the installation and operation of the Inter-Check ICI3000P cash register interface system. Installation should be in accordance with all applicable local and national electric codes, using approv ed materials only . Please familiarize yourself with the inf ...

  • Pelco C1043M-A - page 7

    P elco Manual C1043M-A (2/96) 3 3.0 INST ALLA TION 3.1 SETTING UP ICI1000PIM P ARAMETERS AND BENCH TESTING NOTE: Please familiarize yourself with the information in this manual prior to installation and operation. Contact the customer's register dealer/installer prior to installation and opera- tion. Some warranties and/or service agree- ments ...

  • Pelco C1043M-A - page 8

    4 P elco Manual C1043M-A (2/96) DI P S W I TCH D ESCRI PTI ON- - Swi t ch # F unct i on 1 2 3 4 B ank addr es s B ank addr es s B ank addr es s B ank addr es s 5 6 7 8 l oop baud r at e NC NC 12 34 5678 O PE N 1 2 3 4 5 6 7 8 9 10 11 12 16 15 14 13 VI DEO OUT VI DEO I NP UT S TO M ONI CAMERAS 1 - 15 1 2 3 4 5 6 7 8 9 10 11 12 16 15 14 13 VI DEO OUT ...

  • Pelco C1043M-A - page 9

    P elco Manual C1043M-A (2/96) 5 3.3 ICI3008/ICI3016 INST ALLA TION Refer to Figure 1 for a typical ICI3000P configuration. 1. Connect the 9-pin switcher interface cable (supplied with the ICI3008/ICI3016 switcher) into the port labeled “RS 232” of the ICI3000P . 2. Connect the modular phone plug of the switcher interface cable into the port lab ...

  • Pelco C1043M-A - page 10

    6 P elco Manual C1043M-A (2/96) DI P S W I T CH DE S CRI P T I ON- - Sw i t c h # F unct i on 1 2 3 4 B ank addr es s B ank addr es s B ank addr es s B ank addr es s 5 6 7 8 l oop baud r at e NC NC 12 34 567 8 O PE N 1 2 3 4 5 6 7 8 9 10 11 12 16 1 5 14 13 VI D EO OUT VI D EO I NP UT S TO M O N I CA M E RA S 1 - 1 5 1 2 3 4 5 6 7 8 9 10 11 12 16 1 ...

  • Pelco C1043M-A - page 11

    P elco Manual C1043M-A (2/96) 7 3.3.1 Alarm Pin-out Configuration For detailed 25-pin and 9-pin alarm pin-out configura- tion information, see Figure 5 below . 9-PIN CONNECTOR FOR ICI3008 Pin # Alarm Output 1A l a rm Output 1 2A l a rm Output 2 3A l a rm Output 3 4A l a rm Output 4 5A l a rm Output 5 6A l a rm Output 6 7A l a rm Output 7 8A l a rm ...

  • Pelco C1043M-A - page 12

    8 P elco Manual C1043M-A (2/96) 3.4 EXTERNAL VIDEO ADJUSTMENTS There are five potentiometer adjustments located on the bottom of the Inter-Check unit. These video text ad- justments are for fine tuning only . Major adjustments should be done through the operating software. Use a small tipped, nonmetallic screwdriver for adjusting the potentiometers ...

  • Pelco C1043M-A - page 13

    P elco Manual C1043M-A (2/96) 9 Figure 7 . Inter-Check’ s T wo T e xt Screens S CRE E N # 1 OR TEX T W I NDOW #1 S CRE E N # OR T EXT W I NDO W # 2 2 PE L CO 4.0 PROGRAMMING To enter the SELECT MENU press enter . The following menu will be displayed on monitor: SELECT MENU 1. Register # 1 or 2 2. Operator # 1 or 2 3. Exceptions on/off 4. Camera s ...

  • Pelco C1043M-A - page 14

    10 P elco Manual C1043M-A (2/96) • Press [ 3 ] to select internal synchronization (no video). •P ressing F9 will enable you to select an external camera from PELCO’ s ICI3008/ICI3016 Inter - Check switchers. After pressing F9 , the following prompt will be displayed: Enter select # Select camera number that corresponds to the ICI3008/ICI3016 ...

  • Pelco C1043M-A - page 15

    P elco Manual C1043M-A (2/96) 11 4.6 AUTO CAMERA SEARCH ON/OFF When enabled, this feature monitors your camera system’ s sync generation. If your monitoring camera loses power or is disconnected, the system will auto- matically switch to the next camera for synchroniza- tion. If an active video is not detected, the system will automatically switc ...

  • Pelco C1043M-A - page 16

    12 P elco Manual C1043M-A (2/96) 4.8.2 Number of Lines for Small Screens 1 and 2 This feature enables you to select the number of data lines displayed on each screen. The dif ference between the “small” and “large” screens is that you may reduce the number of lines displayed on the small screen, while the large screen al w ays displays 17 l ...

  • Pelco C1043M-A - page 17

    P elco Manual C1043M-A (2/96) 13 4.8.6 Channel Program Menu 4.8.6.1 Partyline Press [ 6 ]. The follo wing prompt will be displayed: CHANNEL PROGRAM MENU 4. Gr oup P oll List 5. Exception Follo w Alarm Time 6. Gr oup Select 4.8.6.2 Channel Program Menu 1. Baud Rate — Not Applicable 2. RS-232 — Not Applicable 3. ISO-Jack — Not Applicable Group ...

  • Pelco C1043M-A - page 18

    14 P elco Manual C1043M-A (2/96) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 20 21 22 23 24 25 19 18 16 15 17 DB 2 5 - B A CK V I E W PI N 3 = R ECEI VE ( R x ) PI N 7 = G RU N D( DB 2 5 CONNECT O R 1 2 3 4 5 6 7 8 9 DB 9 CONNE CT O R TO S M AR T UNI T DB 9 - B A CK V I E W PI N 3 T A NS M I T ( T x ) PI N 5 = G ROUND ( G n d ) OG nd) =R PR I NTER 4.8.7 Print ...

  • Pelco C1043M-A - page 19

    P elco Manual C1043M-A (2/96) 15 4.8.10 Shadow List Programming This list tells the 8- or 16-position Inter-Check Switcher which camera and POS terminal are linked together . It is also used to program sequential video switching. The [ S ] hotke y is used to turn switcher sequencing on and of f. Press [ 0 ]. A long list of numbers will scroll up th ...

  • Pelco C1043M-A - page 20

    16 P elco Manual C1043M-A (2/96) 4.9 EXCEPTIONS Exceptions are cash register transactions of special interest that can be programmed into the ICI3000P units. T ypical transactions are V OID, REFUND, CASH P AID OUT and NO SALE. These types of transactions can then be used to alarm your VCR or other alarmable de vice for video recording. Exceptions c ...

  • Pelco C1043M-A - page 21

    P elco Manual C1043M-A (2/96) 17 4.9.1 Exceptions using the Column Specific Strategy A Column Specific Exception is used to “flag” a transaction according specific placement of text on the register ticket. As an example, if the word V OID normally appears starting 5 spaces from the left during a void transaction, you would type in the following ...

  • Pelco C1043M-A - page 22

    18 P elco Manual C1043M-A (2/96) 4.9.3 Exceptions Using the Price Point Editing Strategy This type of exception is used to program an exception that is looking for characteristics in the actual price of the item, rather than a specific word. The keyboard character used in this type of exception strategy is a double bar [ ] and is displayed by press ...

  • Pelco C1043M-A - page 23

    P elco Manual C1043M-A (2/96) 19 4.9.4 Exceptions with Descriptors If you would like to describe the type of Exception that is being “flagged”, you can use a descriptor . As an example, with our negati ve total, you may want Inter -Check to print the following: “ NEGA TIVE TOT AL ” follo wing the transaction. This is done by simply typing t ...

  • Pelco C1043M-A - page 24

    20 P elco Manual C1043M-A (2/96) 5.1 REGISTER MASKING This feature allows you to ignore exceptions when they occur on certain registers. As an example, you may ha ve one register dedicated specifically to returns, so you’ll want to ignore refund transactions at this register because they occur constantly . The delete register mask option works co ...

  • Pelco C1043M-A - page 25

    P elco Manual C1043M-A (2/96) 21 6.0 HOT KEY SUMMAR Y LIST [B] BLOCK SELECT Used to select polling for a block of two (2) or four (4) groups of registers. [C][I] CLEAR COMMUNICA TIONS Clears Communication to PIMs and ICI3000P . [E] EXCEPTION FOLLOW ON/OFF The [ E ] key turns on the Exception Follow sequence for Screen 1. When an exception occurs, t ...

  • Pelco C1043M-A - page 26

    22 P elco Manual C1043M-A (2/96) [F8] P AGE BACK/P AGE FOR WARD TOGGLE This option allows you to look back one page of text on your monitor to verify data. By using this key you will automatically force the unit into large screen mode. Pressing [ F8 ] again will bring back the cur - rent page of text. The acti ve page will sho w the cur - sor at th ...

  • Pelco C1043M-A - page 27

    P elco Manual C1043M-A (2/96) 23 7.0 TROUBLESHOOTING This section covers some basic troubleshooting examples and possible solutions for each. Consult this section first before calling your PELCO representative. Problem: ICI3000P unit does not receive data. Solution: Make sure that the data cable is plugged into the D A T A INPUT of the ICI3000P uni ...

  • Pelco C1043M-A - page 28

    24 P elco Manual C1043M-A (2/96) 8.0 POWER-UP PROCEDURE FOR THE ICI3000P In the ev ent of a power f ailure, the Inter-Check System has a nonvolatile memory and will retain all memory that has been previously saved. Some program func- tions, in order to be used, will have to be activated us- ing the hot keys. Fo llowing is a po wer -up procedure che ...

  • Pelco C1043M-A - page 29

    P elco Manual C1043M-A (2/96) 25 9.0 SPECIFICA TIONS W eight: 3 pounds Dimensions: Length = 9.50 inches Wi dth = 5.75 inches Height = 1.50 inches Operating T emperature: 35 ° F to 95 ° F Storage T emperature: -4 ° F to 140 ° F Operating Humidity: 20% to 80% non-condensing ELECTRICAL SPECIFICATIONS: FCC Approved : This equipment has been tested ...

  • Pelco C1043M-A - page 30

    26 P elco Manual C1043M-A (2/96) 9.1 OUTPUT DEFINITIONS WIRE COLOR PIN DESIGNA TION DESCRIPTION White 1 +5 volts (For testing only) Black 2 Signal Ground Red 3 RS232 Current Loop CHANNEL 1 INPUT Green 4 NOT USED Y ellow 5 (Opto y-jack input) ICI1000PIM Input for CHANNEL 1 Blue 6 NOT USED AUXILIAR Y POR T 1 (Printer Port) Communications = Standard R ...

  • Pelco C1043M-A - page 31

    Pelco Manual C1043M-A (2/96) 27 10.0 W ARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1996, Pelco. All rights reserved. WARRANTY Pelco will repair or replace, without charge, any merchandise proved defec ...

  • Pelco C1043M-A - page 32

    28 Pelco Manual C1043M-A (2/96) PELCO 3500 Pelco Way Clovis, CA 93612-5699 USA (559) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (559) 292-3827 International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.) C1043M-A ® ...

Производитель Pelco Категория Home Security System

Документы, которые мы получаем от производителя устройства Pelco C1043M-A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Pelco
- инструкции обслуживания C1043M-A
- паспорта изделия Pelco
- информационные брошюры
- энергетические этикетки Pelco C1043M-A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Pelco C1043M-A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Pelco C1043M-A, инструкции обслуживания, короткие инструкции или инструкции пользователя Pelco C1043M-A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Pelco C1043M-A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Pelco C1043M-A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Pelco C1043M-A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Pelco C1043M-A.

Полная инструкция обслуживания Pelco, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Pelco C1043M-A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Pelco C1043M-A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Pelco C1043M-A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Pelco C1043M-A - которые должны облегчить нам первые шаги во время использования Pelco C1043M-A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Pelco C1043M-A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Pelco C1043M-A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Pelco C1043M-A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Pelco C1043M-A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Pelco C1043M-A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)