    E4H-CE AND E8-CE SERIES W A TER PURIFICA TION MACHINES 3 m 3 /hr to 45 m 3 /hr 18,000 gpd to 288,000 gpd Contr ol Narrative Manual ...

  • GE E4H-CE - page 2

    ...

  • GE E4H-CE - page 3

    GE OSMONICS E4H-CE AND E8-CE W A TER TREA TMENT SYSTEMS CONTROL NARRA TIVE MANUAL T ABLE OF CONTENTS Page 1.0 OVER VIEW 1 1.1 Hardware 1 1.2 Software 1 1.3 Operator Interface T erminal (OIT) 2 2.0 ST AR T -UP 3 2.1 Operation Screen 4 2.2 Alarm History Screen 6 2.3 Machine Status Screen 8 2.4 Utilities Screen 10 2.5 Set-Up Screen 1 1 LIST OF FIGURES ...

  • GE E4H-CE - page 4

    ...

  • GE E4H-CE - page 5

    1 1.0 OVER VIEW The GE Osmonics E4H-CE and E8-CE water treatment systems consist of modular equipment that is designed to work together with the reverse osmosis (RO) machine at the heart of the system. The Programmable Logic Controller (PLC) and Operator Interface T erminal (OIT) are pro- grammed to control a complete, integrated system. A water pu ...

  • GE E4H-CE - page 6

    2 1.3 Operator Interface T erminal (OIT) Screen The available screens for the PanelV iew are as listed: ST AR T -UP: Contact information for customer . OPERA TION: Gives run options for machine, alarm, and status messages. ALARM HIST OR Y : Displays last five alarms conditions. ST A TUS: Displays last five operating conditions. UTILITIES: Adjusts c ...

  • GE E4H-CE - page 7

    3 2.0 ST AR T -UP The ST AR T -UP Screen is displayed upon start-up of the E-CE Series RO machine. This touch screen gives customer contact information. Figure 2.1 S tart-Up Screen T o get to the next screen, press anywhere on the screen or wait twenty (20) seconds. ...

  • GE E4H-CE - page 8

    4 2.1 Operation Screen The Operation Screen displays the control function for the E-CE Series RO machine. Figure 2.2 Operation Screen NO. FUNCTION OPERA TION 1 RO Switches machine to run 2 AUTO/HAND Switches machine to Auto or Hand 3 CIP Switches machine to CIP mode 4 FILL Energizes the inlet solenoid valve to fill machine 5 PURGE Manually puts RO ...

  • GE E4H-CE - page 9

    5 The RO machine is controlled using the Operation Screen. The FILL button energizes the inlet solenoid valve allowing the RO machine to fill water . The machine will run for ten (10) minutes filling the machine. This needs to be done before the RO machine can oper- ate. Once the machine has been filled the RO, CIP , and PURGE buttons will operate. ...

  • GE E4H-CE - page 10

    6 2.2 Alarm History Screen The ALARM Message, located above the Control Buttons, shows the user current Alarm Conditions. Figure 2.3 Alarm History Screen NUMBER FUNCTION OPERA TION 1 BACK T akes user back to OPERA TION Screen 2 ALARM T akes user to ALARM Screen 3 ALARM RESET Resets current ALARM conditions 4 UTILITIES T akes users to UTILITIES Scre ...

  • GE E4H-CE - page 11

    7 T able 2.1 Alarm Messages * Set at factory . ALARM DISPLA YED LOW INLET PRESSURE HI PERMEA TE PRESSURE HI TEMP HIGH pH HIGH CONDUCTIVI- TY MOTOR 1 ST ART F AILURE E-STOPPED PRESSED ACTION Shuts down RO machine Shuts down RO machine Shuts down RO machine Alarm light dis- played on pH meter Shuts down RO machine Shuts down RO machine Shuts down RO ...

  • GE E4H-CE - page 12

    8 2.3 Machine Status Screen The Machine Status Screen displays the last five run conditions. Figure 2.4 Machine S tatus Screen NUMBER FUNCTION OPERA TION 1 BACK T akes user back to OPERA TION Screen 2 ALARM T akes user to ALARM Screen 3 ALARM RESET Resets current ALARM Conditions 4 UTILITIES T akes users to UTILITIES Screen 1 23 4 ...

  • GE E4H-CE - page 13

    9 T able 2.2 S tatus Screen System Message SYSTEM MESSAGE RO MODE CIP MODE PERMEA TE PURGE MODE MANUAL SHUTDOWN ALARM SHUTDOWN PRETREA TMENT SER VICE POST -TREA TMENT SER VICE DEFINITION Normal Operating Mode. Clean-In-Place Mode used for cleaning. Permeate is “recycled” back through RO machine. RO machine switched OFF by manually pressing ON/O ...

  • GE E4H-CE - page 14

    10 2.4 Utilities Screen The Utilities Screen allows the user to adjust contrast, screen center , and clean the display . Figure 2.5 Utilities Screen NO. FUNCTION OPERA TION 1 CONTRAST + Darkens OIT Screen 2 CONTRAST - Lightens OIT Screen 3 CALIBRA TE Allows users to adjust SCREEN position of OIT Screen 4 CLEAN Allows users to adjust OIT SCREEN Scre ...

  • GE E4H-CE - page 15

    11 2.5 Set-Up Screen The Set-Up Screen allows the users to clear Alarm History , run time, and status. This Screen allows users to download new program information. Figure 2.6 Screen Set-Up * Alarm History , Status History , and Run T ime Reset Buttons must be held for 15 seconds to clear or reset. NO. FUNCTION OPERA TION 1* ALARM Clears history of ...

  • GE E4H-CE - page 16

    ...

  • GE E4H-CE - page 17

    Corporate Headquarters 5951 Clearwater Drive Minnetonka, MN 55343-8995 USA (952) 933-2277 Phone (952) 933-0141 Fax Euro/Africa Operations 230 rue Robert Schuman Z A des Uselles F-77350 Le MØe sur Seine FRANCE +33 1 64 10 2000 Phone +33 1 64 10 3747 Fax Asia/Pacific Operations 1044/8 SOI 44/2 Sukhumvit Road Prakanong Bangkok 10110 THAILAND +66 2 38 ...

Производитель GE Категория Water System

Документы, которые мы получаем от производителя устройства GE E4H-CE мы можем разделить на несколько групп. Это в частности:
- технические чертежи GE
- инструкции обслуживания E4H-CE
- паспорта изделия GE
- информационные брошюры
- энергетические этикетки GE E4H-CE
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания GE E4H-CE.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа GE E4H-CE, инструкции обслуживания, короткие инструкции или инструкции пользователя GE E4H-CE. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия GE E4H-CE.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства GE E4H-CE, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании GE E4H-CE пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей GE E4H-CE.

Полная инструкция обслуживания GE, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией GE E4H-CE - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания GE E4H-CE, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся GE E4H-CE, которое найдем в данном документе
3. Советы по использованию основных функций устройства GE E4H-CE - которые должны облегчить нам первые шаги во время использования GE E4H-CE
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем GE E4H-CE
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра GE E4H-CE в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся GE E4H-CE?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с GE E4H-CE, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с GE E4H-CE со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)