Инструкция обслуживания Foster F40

23 страниц 0.99 mb
Скачать

Перейти на страницу of 23

Summary
  • Foster F40 - page 1

    Service Manual Service Manual F20, F40, F60, F85 & FCI20, FCI30, FCI40 FCI60, FCI85 Cube Ice Mak er Foster Refrigerator Oldmedow Road, King’s L ynn, Norfolk PE30 4JU England T el: 01553 691 122 Fax: 01553 691447 Website: www .fosterrefrigerator .co.uk E-mail: sales@foster-uk.com a Division of ITW (UK) Ltd. F/FCI/SM/02/03 ...

  • Foster F40 - page 2

    CONTENTS Page 1. General Information and Installation Instructions 2 1.1 Introduction 2 1.2 Unpacking and Inspection 2 1.3 Location and Leveling 2 1.4 W ater Supply and Drain Connections 2-3 1.5 Final Checklist 3 1.6 Installation Practice 3 2. F20 and F40 T echnical Data and Operating Instructions 4 3. F60 and F85 T echnical Data and Operating Inst ...

  • Foster F40 - page 3

    1. General Information and Installation Instructions 1.1 Introduction The Electronic Cubers are quality designed, engineered and manufactured. Their ice making systems are thoroughly tested providing the utmost in flexibility to fit the needs of a particular user . These icemakers have been engineered to our own rigid safety and performance stand ...

  • Foster F40 - page 4

    fittings and a shut off valve installed in an accessible position between the water supply line and the unit. W A TER SUPPL Y - W A TER COOLED MODELS. The water cooled versions require two separate inlet water supplies on models 40 and 60, one to supply water for the ice production and one for the water cooled condenser . Connect the male fitting ...

  • Foster F40 - page 5

    2. F20 and F40 T echnical Data and Operating Instructions 2.1 T echnical Data Model F20 F40 Output – kg/24hr 19.5 34.5 Bin storage capacity – kg 6.5 15 Cubes per cycle 16 24 Cubes kg per cycle 0.28 0.42 Cycle time – minutes 20.7 17.5 Amps start/run 1 1Amps/2Amps 17Amps/3.3Amps W atts consumption (30°C Ambient T emp) 320w 450w W ater consumpt ...

  • Foster F40 - page 6

    3. F60 and F85 T echnical Data and Operating Instructions 3.1 T echnical Data Model F60 F85 Output – kg/24hr 60 83 Bin storage capacity – kg 27 27 Cubes per cycle 48 48 Cubes kg per cycle 0.84 0.84 Cycle time – minutes 19.0 15.5 Amps start/run 19/4.1 26/5.5 W atts consumption (30°C Ambient T emp) 630 780 W ater consumption (Water T emp at 15 ...

  • Foster F40 - page 7

    I. The machine may stop working if the condenser temperature exceeds the pre-set temperature of the Over T emperature Thermostat (non- adjustable) due to a very high ambient temperature, condenser fan failure, dirty/ blocked condenser. T o restart the machine, depress the protruding button on the Alarm Reset. J. Changes to the defrost time. Under n ...

  • Foster F40 - page 8

    F20 & F40 A/W Wiring Diagram 7 the service and inspection operations. IN OPERA TION: The unit is running through the freezing and defrost cycle stopping automatically only at full bin situation. RE-SET/HI TEMPERA TURE: T o be selected to resume the unit operation when the ice maker shuts off due to the intervention of the condenser temperature ...

  • Foster F40 - page 9

    4. T echnical Specification - R22 Machines MODEL FCI 20 FCI 30 FCI 40 FCI 60 FCI 85 Output – kg/24hr . 18 (20.5) 26 (34) 34 (42) 57 (70) 78 (90) Bin storage capacity – kg 6.5 15 15 27 27 Cubes per cycle 16 24 24 48 48 kg per cycle 0.28 (0.38) 0.42 (0.6) 0.42 (0.6) 0.82 (1.2) 0.82 (1.2) Cycle time – minutes 22 (25) 23.5 (24.5) 15.75 (19.15) 2 ...

  • Foster F40 - page 10

    COMPRESSOR, W A TER INLET SOLENOID V AL VE, HOT GAS V AL VE NOTE: The length of the defrost cycle is (non-adjustable) automatically determined by the microprocessor of The P .C. BOARD in relation to the time T2 necessary for the unit to reduce the evaporator temperature from 0˚C (35˚F) to -1 3˚C (8.5˚F) and of the ambient temperature, as illust ...

  • Foster F40 - page 11

    7. The DIP . SWITCH keys setting is made in consideration of the model and of the type of condenser used (air or water cooled). In T able B, page 12, are indicated the various lengths of the third portion of freezing cycle (T ime mode) in accordance with the different combinations of the DIP . SWITCH KEYS. In T able A, page 12, are indicated the DI ...

  • Foster F40 - page 12

    B. ICE BIN LEVEL SENSOR The ice bin level temperature sensor , secured to one of the storage bin walls, stops the operation of the entire ice maker at the end of the defrost cycle when its sensing probe (in contact with the stored ice) reaches the temperature of +2˚C (35˚F) lighting up, in the meantime, the third RED LED. Once the ice is removed ...

  • Foster F40 - page 13

    7. Dip Switch Positions DIP SWITCHES FCI 20 FCI 30 FCI 40 FCI 60 FCI 85 1 ON ON ON ON ON 2 OFF OFF OFF OFF OFF 3 ON OFF ON ON ON 4 OFF OFF OFF ON ON 5 ON ON ON ON ON 6 OFF OFF OFF OFF OFF 7 ON ON ON ON ON 8 OFF OFF OFF OFF OFF 9 OFF OFF OFF OFF OFF 10 OFF OFF OFF OFF ON T able C LENGTH OF THE DEFROST CYCLE T s ACCORDING TO THE TIME OF T2 T2 T s T2 ...

  • Foster F40 - page 14

    7. Dip Switch Positions DIP SWITCHES FCI 20 FCI 30 FCI 40 FCI 60 FCI 85 1 ON ON ON ON ON 2 OFF OFF OFF OFF OFF 3 ON OFF ON ON ON 4 OFF OFF OFF ON ON 5 ON ON ON ON ON 6 OFF OFF OFF OFF OFF 7 ON ON ON ON ON 8 OFF OFF OFF OFF OFF 9 OFF OFF OFF OFF OFF 10 OFF OFF OFF OFF ON T able C LENGTH OF THE DEFROST CYCLE T s ACCORDING TO THE TIME OF T2 T2 T s T2 ...

  • Foster F40 - page 15

    B. ICE BIN LEVEL SENSOR The ice bin level temperature sensor , secured to one of the storage bin walls, stops the operation of the entire ice maker at the end of the defrost cycle when its sensing probe (in contact with the stored ice) reaches the temperature of +2˚C (35˚F) lighting up, in the meantime, the third RED LED. Once the ice is removed ...

  • Foster F40 - page 16

    7. The DIP . SWITCH keys setting is made in consideration of the model and of the type of condenser used (air or water cooled). In T able B, page 12, are indicated the various lengths of the third portion of freezing cycle (T ime mode) in accordance with the different combinations of the DIP . SWITCH KEYS. In T able A, page 12, are indicated the DI ...

  • Foster F40 - page 17

    COMPRESSOR, W A TER INLET SOLENOID V AL VE, HOT GAS V AL VE NOTE: The length of the defrost cycle is (non-adjustable) automatically determined by the microprocessor of The P .C. BOARD in relation to the time T2 necessary for the unit to reduce the evaporator temperature from 0˚C (35˚F) to -1 3˚C (8.5˚F) and of the ambient temperature, as illust ...

  • Foster F40 - page 18

    4. T echnical Specification - R22 Machines MODEL FCI 20 FCI 30 FCI 40 FCI 60 FCI 85 Output – kg/24hr . 18 (20.5) 26 (34) 34 (42) 57 (70) 78 (90) Bin storage capacity – kg 6.5 15 15 27 27 Cubes per cycle 16 24 24 48 48 kg per cycle 0.28 (0.38) 0.42 (0.6) 0.42 (0.6) 0.82 (1.2) 0.82 (1.2) Cycle time – minutes 22 (25) 23.5 (24.5) 15.75 (19.15) 2 ...

  • Foster F40 - page 19

    F20 & F40 A/W Wiring Diagram 7 the service and inspection operations. IN OPERA TION: The unit is running through the freezing and defrost cycle stopping automatically only at full bin situation. RE-SET/HI TEMPERA TURE: T o be selected to resume the unit operation when the ice maker shuts off due to the intervention of the condenser temperature ...

  • Foster F40 - page 20

    I. The machine may stop working if the condenser temperature exceeds the pre-set temperature of the Over T emperature Thermostat (non- adjustable) due to a very high ambient temperature, condenser fan failure, dirty/ blocked condenser. T o restart the machine, depress the protruding button on the Alarm Reset. J. Changes to the defrost time. Under n ...

  • Foster F40 - page 21

    3. F60 and F85 T echnical Data and Operating Instructions 3.1 T echnical Data Model F60 F85 Output – kg/24hr 60 83 Bin storage capacity – kg 27 27 Cubes per cycle 48 48 Cubes kg per cycle 0.84 0.84 Cycle time – minutes 19.0 15.5 Amps start/run 19/4.1 26/5.5 W atts consumption (30°C Ambient T emp) 630 780 W ater consumption (Water T emp at 15 ...

  • Foster F40 - page 22

    2. F20 and F40 T echnical Data and Operating Instructions 2.1 T echnical Data Model F20 F40 Output – kg/24hr 19.5 34.5 Bin storage capacity – kg 6.5 15 Cubes per cycle 16 24 Cubes kg per cycle 0.28 0.42 Cycle time – minutes 20.7 17.5 Amps start/run 1 1Amps/2Amps 17Amps/3.3Amps W atts consumption (30°C Ambient T emp) 320w 450w W ater consumpt ...

  • Foster F40 - page 23

    fittings and a shut off valve installed in an accessible position between the water supply line and the unit. W A TER SUPPL Y - W A TER COOLED MODELS. The water cooled versions require two separate inlet water supplies on models 40 and 60, one to supply water for the ice production and one for the water cooled condenser . Connect the male fitting ...

Производитель Foster Категория Microphone

Документы, которые мы получаем от производителя устройства Foster F40 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Foster
- инструкции обслуживания F40
- паспорта изделия Foster
- информационные брошюры
- энергетические этикетки Foster F40
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Foster F40.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Foster F40, инструкции обслуживания, короткие инструкции или инструкции пользователя Foster F40. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Foster F40.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Foster F40, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Foster F40 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Foster F40.

Полная инструкция обслуживания Foster, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Foster F40 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Foster F40, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Foster F40, которое найдем в данном документе
3. Советы по использованию основных функций устройства Foster F40 - которые должны облегчить нам первые шаги во время использования Foster F40
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Foster F40
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Foster F40 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Foster F40?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Foster F40, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Foster F40 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)