    292043-UIM-B-0707 SINGLE PIECE AIR HANDLERS MODELS: F*FP INSTALLATION MANUAL ISO 9001 Certified Quality Management System SAFETY This is a safety alert symbol . When you see this symbol on labels or in manuals, be alert to the potential for personal injury . Understand and pay particular attention to the signal words D ANGER , WA R N I N G , or CAU ...

  • Coleman F*FP - page 2

    292043-UIM-B-0707 2 Unitary Products Group SPECIFIC SAFETY RULES AND PRE CA U TIONS 1. Install this air handler only in a location and position as specified in SECTION I of these instructions. 2. Always install the air handler to operate within the air handler ’s intended maximum outlet air t emperature. Only connect the air handler to a duct sys ...

  • Coleman F*FP - page 3

    292043-UIM-B-0707 Unitary Products Group 3 6. When an evaporator coil is instal led in an attic or above a finished ceiling, an auxiliary dr ain pan should be provided under the coil as is specified by most local building codes. 7. Proper electrical supply must be available. 8. Clearances must also be taken in to consideration, and provided for as ...

  • Coleman F*FP - page 4

    292043-UIM-B-0707 4 Unitary Products Group FIGURE 3: Filter Access & Drain Pan Conversion / Coil Baffle FIL TER 4B - SIDE VIEW "S" BRACKET MUST BE USED TO F ASTEN DUCT WORK T O FRONT OF UNIT RETURN AIR DUCT 3/4" PVC SOCKETS FOR HORIZONT AL DRAIN APPLICA TION HORIZONT AL DRAIN P AN POSITION "A” HORIZONT AL DRAIN P AN POSITI ...

  • Coleman F*FP - page 5

    292043-UIM-B-0707 Unitary Products Group 5 DUCT CONNECTIONS NOTE: The electric heat accessory s hould be installed before the sup- ply air duct is attached to the suppl y air openings. Refer to the electric heater kit instructions for proper installation. Air supply and return may be handled in one of several ways best suited to the installation. S ...

  • Coleman F*FP - page 6

    292043-UIM-B-0707 6 Unitary Products Group • If the suction line is 3/4" diamet er - position the bulb near the top of the copper tube as show n. If the tube is 7/8" diameter - position the bulb near the bottom of the tube. Refer to Figure 7. • Wrap the clamp, bulb & line securely with insulation provided. NOTE: The coil should be ...

  • Coleman F*FP - page 7

    292043-UIM-B-0707 Unitary Products Group 7 ...

  • Coleman F*FP - page 8

    292043-UIM-B-0707 8 Unitary Products Group LO W VOL T A GE CONTR OL CONNECTION The 24 volt power supply is provi ded by an int ernally wired low voltage transformer which is standard on all model s. However, if the unit is con - nected to a 208 volt power supply the low voltage transformer must be rewired to the 208 volt tap. See the unit wiring la ...

  • Coleman F*FP - page 9

    292043-UIM-B-0707 Unitary Products Group 9 TA B L E 3 : Physical and Electrical Data Models F*FP 024 030 036 040 Blower - Diameter x Width 10 x 6 10 x 8 10 x 8 10 x 8 Motor HP 1/4 1/3 1/2 1/3 Nominal RPM 1075 1075 1075 1075 V oltage 208/230 Amps Full Load (208/230) 1.6/1.4 (50 Hz:2.1) 2.5 / 2.2 3.3/2.9 (50 Hz:2.3) 2.5 / 2.2 Locked Rotor (208/230) 3 ...

  • Coleman F*FP - page 10

    292043-UIM-B-0707 10 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). TA B L E 6 : Electrical Data - 1 Ø - 2 08/230-1 -60 1 Models F*FP Heater* Model Max. St atic & Min. CFM T otal Heat 2 KW St aging 3 KW MBH W1 Only W2 Only W1 + W2 St atic T ap 208V 240V 208V 2 40V 208V 240V 2 08V 240V 208V 240V 024 2HK*6500506B 0.5 Low 3.8 ...

  • Coleman F*FP - page 11

    292043-UIM-B-0707 Unitary Products Group 11 * May be 0 (no breaker) or 1 (with breaker). TA B L E 7 : Electrical D a t a - (For Single Source Power Supply) - Copper W ire 1 Ø - 20 8/230-1-60 1 Models F*FP Heater* Model Heater Amps 240V Field W iring Min. Circuit Ampacity Max. O.C.P . 2 Amps /T ype 75 ° C Wir e Size - A WG 208V 240V 208V 240V 208V ...

  • Coleman F*FP - page 12

    292043-UIM-B-0707 12 Unitary Products Group TA B L E 9 : Electrical Data - 3 Ø - 2 08/230-3 -60 1 Models F*FP Heater 2 Model Max. St atic & Min. CF M T ot al Heat KW St aging 3 KW MBH W1 Only W2 On ly W1 + W2 St atic T ap 208 240 208 240 208 240 208 240 208 240 024 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 030 2HK0650102 ...

  • Coleman F*FP - page 13

    292043-UIM-B-0707 Unitary Products Group 13 All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater . TA B L E 1 1 : Airflow Data for 2 30 V olt - Heat Pump Models 1 1. Includes Return Air Filter and Largest Electric Heate r. Models Blower Motor S ...

  • Coleman F*FP - page 14

    292043-UIM-B-0707 14 Unitary Products Group T A BLE 12: Airflow Data 1 for 208 V olt - Heat Pump Models 1. Includes Return Air Filter and Largest Electric Heate r . All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater . Models Blower Motor Spee ...

  • Coleman F*FP - page 15

    292043-UIM-B-0707 Unitary Products Group 15 NOTES: 1. “Y” T erm inal on Air Handler Control Bo ard must be connected for full CFM and applications requiring 60 second Blower Off Del ay for SEER enhancement. 2. 1 Optional Dehumidification Humidi stat con tacts open on rise. 3. For F4FV model - Remove Humidistat Jumper on CFM Selection Board - if ...

  • Coleman F*FP - page 16

    Subject to change without notice. Printed in U.S.A. 292043-UIM-B-0707 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 292043-UIM-A-0507 Unitary 5005 Norman Product Y ork OK Group Drive 73069 DRAIN CONNECTIONS All drain lines should be trapped a minimum of three inches, should be pitched away from unit dr ain pan and ...

Производитель Coleman Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Coleman F*FP мы можем разделить на несколько групп. Это в частности:
- технические чертежи Coleman
- инструкции обслуживания F*FP
- паспорта изделия Coleman
- информационные брошюры
- энергетические этикетки Coleman F*FP
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Coleman F*FP.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Coleman F*FP, инструкции обслуживания, короткие инструкции или инструкции пользователя Coleman F*FP. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Coleman F*FP.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Coleman F*FP, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Coleman F*FP пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Coleman F*FP.

Полная инструкция обслуживания Coleman, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Coleman F*FP - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Coleman F*FP, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Coleman F*FP, которое найдем в данном документе
3. Советы по использованию основных функций устройства Coleman F*FP - которые должны облегчить нам первые шаги во время использования Coleman F*FP
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Coleman F*FP
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Coleman F*FP в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Coleman F*FP?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Coleman F*FP, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Coleman F*FP со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)