    ARC STICK WELDER - 70 AMP Model 97717 SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our web ...

  • Chicago Electric 97717 - page 2

    Page 2 SKU 97717 For technical questions, please call 1-800-444-3353. CONTENTS IMPORT ANT SAFETY INFORMA TION ..................................................... 3 GENERAL SAFETY RULES .................................................................................... 3 SPECIFIC SAFETY RULES ...................................................... ...

  • Chicago Electric 97717 - page 3

    Page 3 SKU 97717 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s seria l number in the back of the manual near the assembly diagram (or month and year of purchase if product h ...

  • Chicago Electric 97717 - page 4

    Page 4 SKU 97717 For technical questions, please call 1-800-444-3353. Do not touch exposed electrical b. parts. Do not expose power tools to rain c. or wet conditions. W ater entering a power tool will increase the risk of electric shock. Do not abuse the cord. Never use d. the cord for pulling or unplugging the power tool. Keep cord away from heat ...

  • Chicago Electric 97717 - page 5

    Page 5 SKU 97717 For technical questions, please call 1-800-444-3353. Use the power tool, accessories and f. tool bits etc., in accordance with these instructions and in the manner intended for the particular type of power tool, taking into account the working conditions and the work to be performed. Use of the power tool for operations different f ...

  • Chicago Electric 97717 - page 6

    Page 6 SKU 97717 For technical questions, please call 1-800-444-3353. avoid electrical shock. • Any power cord must be properly grounded. Ground Fault Circuit Interrupter (GFCI) should also be implemented – it prevents sustained electrical shock. W ARNING: This product, when used 1 1. for welding, plasma cutting, soldering, or similar applicati ...

  • Chicago Electric 97717 - page 7

    Page 7 SKU 97717 For technical questions, please call 1-800-444-3353. Do not dispose of hot slag in • containers holding combustible materials. Keep a re extinguisher nearby and know how to use it. After spot welding, make a • thorough examination for evidence of re. Be aware that easily- visible smoke or ame may not be present for som ...

  • Chicago Electric 97717 - page 8

    Page 8 SKU 97717 For technical questions, please call 1-800-444-3353. W ARNING INHALA TION HAZARD: Welding and Plasma Cutting Produce TOXIC FUMES. Exposure to welding or cutting exhaust fumes can increase the risk of developing certain cancers, such as cancer of the larynx and lung cancer . Also, some diseases that may be linked to exposure to weld ...

  • Chicago Electric 97717 - page 9

    Page 9 SKU 97717 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz Power Plug: 20 Amp/3 Prong / Grounded Input Current 20 Amps Power Switch T ype Rocker with Light (Y ellow) Indicators Thermal Overload Light (Red) Settings Minimum: 50 Amp Maximum: 70 Amp Welding Capacity Up to 1/8” Thick S ...

  • Chicago Electric 97717 - page 10

    Page 10 SKU 97717 For technical questions, please call 1-800-444-3353. install a 120 volt, 20 Amp, 3-hole, grounded electrical outlet. (See Figure B.) OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. TO PR ...

  • Chicago Electric 97717 - page 11

    Page 1 1 SKU 97717 For technical questions, please call 1-800-444-3353. cycle (at 70 Amps), actual welding can occur for one minute and then the welder must cool for nine minutes . At a 20% duty cycle (at 50 Amps), welding can occur for 2 minutes and then the welder must cool for 8 minutes . Failure to carefully observe duty • cycle limitations c ...

  • Chicago Electric 97717 - page 12

    Page 12 SKU 97717 For technical questions, please call 1-800-444-3353. Switch (13) to its “OFF” position and wait about 10 minutes. Then restart the Welder . (See Assy . Diagram.) When the weld is complete, lift the 1 1. electrode clearly away from any grounded object. Set the Welding Shield down, and turn the power Switch (13) to its “OFF” ...

  • Chicago Electric 97717 - page 13

    Page 13 SKU 97717 For technical questions, please call 1-800-444-3353. Problem Possible Causes Possible Solutions Welder does not “hum” when turned on. No power at electrical outlet. 1. Broken or damaged Power Cord. 2. Check circuit fuse or circuit breaker . 1. Have Power Cord repaired or replaced by 2. a qualied electrician. Welder “hums? ...

  • Chicago Electric 97717 - page 14

    Page 14 SKU 97717 For technical questions, please call 1-800-444-3353. P ARTS LIST AND ASSEMBL Y DIAGRAM Part # Description Qty . Part # Description Qty . 1 Cord Strain Relief (1.0mm) 1 13 Power Switch (Y ellow) 1 2 Screw (ST3.9x13) 18 14 Cord Strain Relief (3.0mm) 2 3 Case 1 15 Screw (M5 x 25) 3 4 T emperature Control 1 16 Spring W asher (#5) 3 5 ...

  • Chicago Electric 97717 - page 15

    Page 15 SKU 97717 For technical questions, please call 1-800-444-3353. Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts. LIMITED 1 YEAR / 90 DA Y W A ...

Производитель Chicago Electric Категория Welder

Документы, которые мы получаем от производителя устройства Chicago Electric 97717 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Chicago Electric
- инструкции обслуживания 97717
- паспорта изделия Chicago Electric
- информационные брошюры
- энергетические этикетки Chicago Electric 97717
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Chicago Electric 97717.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Chicago Electric 97717, инструкции обслуживания, короткие инструкции или инструкции пользователя Chicago Electric 97717. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Chicago Electric 97717.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Chicago Electric 97717, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Chicago Electric 97717 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Chicago Electric 97717.

Полная инструкция обслуживания Chicago Electric, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Chicago Electric 97717 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Chicago Electric 97717, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Chicago Electric 97717, которое найдем в данном документе
3. Советы по использованию основных функций устройства Chicago Electric 97717 - которые должны облегчить нам первые шаги во время использования Chicago Electric 97717
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Chicago Electric 97717
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Chicago Electric 97717 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Chicago Electric 97717?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Chicago Electric 97717, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Chicago Electric 97717 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)