    SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Save This Manual For Future Reference. I:RRFTSMRN ° PROFESSIONAL "HYDROGLASS ''® SHALLOW WELL JET PUMP • Safety Instructions • Installation • Operation • Troubleshootin ...

  • Sears 390.2514 - page 2

    READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety aler'c symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: DANGER warns about hazards that will cause serious personal injury, death or major property damage ff ignored. WARNING warn ...

  • Sears 390.2514 - page 3

    CONTENTS Safety .............................................................................................. 2 Warranty/Introduction ................................................................... 3 Pump Performance ........................................................................ 3 Major Components .................................... ...

  • Sears 390.2514 - page 4

    MAJOR COMPONENTS / PIPING MAJOR COMPONENTS AND WHAT THEY DO NOTICE: Use Teflon tape supplied with the pump for making all threaded connections to the pump. Impeller and Jet Impeller turns with motor shaft, causing water to fly out from its rim by centrifugal force. Impeller rotation creates a vacuum which pulls in more water. Part of the water is d ...

  • Sears 390.2514 - page 5

    ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Motor Switch Settings If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor. NOTICE: Never wire a 115 volt motor to a 230 ...

  • Sears 390.2514 - page 6

    ELECTRICAL WIRING CONNECTIONS [_.WARNING_ Fire hazard. Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty. The supply voltage must be within ± 10% of the motor nameplate voltage. NOTICE: Dual-voltage motors are factory wired for 230 volts. If nec- essary, reconnect the motor for 115 volts, as shown. Do not alte ...

  • Sears 390.2514 - page 7

    INSTALLATION / OPERATION INSTALLATION SEARS jet pumps should be used with Captive Air* Tanks (See Figure 7). I_IMINGpLU8 PRESSURE $WITGH TO,_ICE BUILT-IN ( VALVE __. 1-114" pLASTIC pIp_ pLASTIC FtPE ADAPTER* PUMPTOTANK SIDE VIEW ;ApTNE AIF_ TANK Figure 7 For mounting pump to tank, purchase tank fittings Kit No. 2788. SEARS Captive Ai_ Tanks ar ...

  • Sears 390.2514 - page 8

    SERVICE MAINTAINING YOUR PUMP Lubrication It is not necessary to lubricate the pump or its motor. The motor bearings are lubricated for life. The mechanical shaft seal in the pump is water lubricated and self-adjusting. Draining for Winter When the pump is to be disconnected from service, or is in dan- ger of freezing, it must be drained. The pump ...

  • Sears 390.2514 - page 9

    SERVICE C. With finger pressure press seat firmly and squarely into cav- ity. See Figure 12A. Polished face of seat faces inside of pump. If seat will not locate properly, place cardboard washer over polished face and use piece of 3/4" standard pipe for press- hag purposes. See Figure 12B. Figure 12B 483 0194 D. Dispose of cardboard washer and ...

  • Sears 390.2514 - page 10

    REPAIR PARTS 29 28 I 1 / 26 2 3 3A 7 8 lO 25 25A 23 766 1194 22 21 19 20 ]0 ...

  • Sears 390.2514 - page 11

    REPAIR PARTS 1/2 HP 3/4 HP Key Model Model Part No. 390,2514 390.2518 Description 1"* 2 3* 3A 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21" 22 23 24 25* 25A* 26 27 28* 29 J218-953C 17351-0009 WC78-41T L176-47P U9-399 U 109-6A J 105-40PE J1-39P U30-542SS C19-54SS U9-201 N32P-66 N34P-19 N76-29P J20-18 N176-28PB U37-673P U111-212T U9-226 ...

  • Sears 390.2514 - page 12

    TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSES REMEDIES Motor will not run. 1. Disconnect switch is off. 1. Be sure switch is on. 2. Fuse is blown. 2. Replace fuse. 3. Starting switch is defective. 3. Replace starting switch. 4. Wires at motor are loose, 4. Refer to instroctions on wiring. disconnected, or wired incorrectly. Check and tighten all wi ...

  • Sears 390.2514 - page 13

    13 ...

  • Sears 390.2514 - page 14

    14 ...

  • Sears 390.2514 - page 15

    15 ...

  • Sears 390.2514 - page 16

    SEARS OWNER'S MANUAL MODEL NO. 390.2514 390.2518 The model number of your Shallow Well Jet Pump will be found on the pump body. When requesting service or ordering parts, always give the following information: • Product Type • Model Number • Part Number • Part Description CRRFTSMRW PROFESSIONAL "HYDROGLASS ''® SHALLOW W ...

Производитель Sears Категория Water Pump

Документы, которые мы получаем от производителя устройства Sears 390.2514 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Sears
- инструкции обслуживания 390.2514
- паспорта изделия Sears
- информационные брошюры
- энергетические этикетки Sears 390.2514
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Sears 390.2514.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Sears 390.2514, инструкции обслуживания, короткие инструкции или инструкции пользователя Sears 390.2514. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Sears 390.2514.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Sears 390.2514, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Sears 390.2514 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Sears 390.2514.

Полная инструкция обслуживания Sears, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Sears 390.2514 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Sears 390.2514, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Sears 390.2514, которое найдем в данном документе
3. Советы по использованию основных функций устройства Sears 390.2514 - которые должны облегчить нам первые шаги во время использования Sears 390.2514
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Sears 390.2514
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Sears 390.2514 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Sears 390.2514?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Sears 390.2514, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Sears 390.2514 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)