    O WNER ’ S OPERA TION AND INST ALLA TION MANUAL W ARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation an d operational procedures. For assistance or additional info r mation consult a qualified installer, service agency, or gas supplier. ...

  • Procom ML200TBA - page 2

    2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f o r use with other gases. 2. Do not place propane/LP supply tank(s) inside any ...

  • Procom ML200TBA - page 3

    3 PRODUCT FEA TURES SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxyg en Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, batter ...

  • Procom ML200TBA - page 4

    4 FRESH AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Con ...

  • Procom ML200TBA - page 5

    5 W ARNING: Rework worksheet, add- ing the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must p ...

  • Procom ML200TBA - page 6

    6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces ...

  • Procom ML200TBA - page 7

    7 INST ALLA TION Figure 8 - Mounting Bracket Clearances Figure 7 - Removing Lower Front Panel Of Heater Figure 4 -Mounting Clearances As V iew From Front Of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. IMPORT ANT : V ent-free heaters add moisture to ...

  • Procom ML200TBA - page 8

    8 INST ALLA TION Figure 1 1 - Mounting Heater Onto Mounting Bracket Figure 9 - Folding Anchor Figure 10 - Popping Open Anchor Wing For Thin W alls Attaching Mounting Bracket to W all Note: W all anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mo ...

  • Procom ML200TBA - page 9

    9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an exte ...

  • Procom ML200TBA - page 10

    10 Figure 15 -Equipment Shutoff V alve INST ALLA TION CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leak ...

  • Procom ML200TBA - page 11

    11 Figure 17 - Control Knob In The OFF Position Figure 18 - Pilot OPERA TING YOUR HEA TER THERMOST A T MODELS  LIGHTING  INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to th e OFF position. NOTE : knob cannot be turned f ...

  • Procom ML200TBA - page 12

    12 OPERA TING YOUR HEA TER NON-THERMOST A T MODELS  FOR YOUR SAFETY  READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the app ...

  • Procom ML200TBA - page 13

    13 Figure 21 - Correct Pilot Flame Pattern Figure 22 - Incorrect Pilot Flame Pattern BURNER FLAME P A TTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If pilot flame pattern is incorrect, as shown in Figure 24.  turn heater of f (see T o T urn Off Gas T o Appliance. page 12 for non- thermos ...

  • Procom ML200TBA - page 14

    14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM When ignitor button is pressed in, there is no spark at ODS/pilot. ...

  • Procom ML200TBA - page 15

    15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Y ellow flame during burner combustio n. Slight smoke or odor during initial operation. Heater produces a whistling noise when burner is lit. Heater produces a clicking/ticking noise just ...

  • Procom ML200TBA - page 16

    16 TROUBLESHOOTING Continued W ARNING: If you smell gas  Shut off gas supply .  Do not try to light any appliance.  Do not touch any electrical switch; do not use any phone in your building.  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.  If you cannot reach your gas supplier, ...

  • Procom ML200TBA - page 17

    17 SPECIFICA TIONS Note: Dimensions listed are outer most points on the heater (includes control knobs and grill). * For purposes of input adjustment. REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. P ARTS UNDER W ARRANTY Contact authorized dealer from whom yo ...

  • Procom ML200TBA - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN THERMOST A T MODELS ML200TBA ML300TBA ...

  • Procom ML200TBA - page 19

    19 P ARTS LIST THERMOST A T MODELS ML200TBA, ML300TBA This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24-1 24-2 25 26 27 28 29 ML300TBA P ART NO. MB10002 MB09 ...

  • Procom ML200TBA - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN NON-THERMOST A T MODELS ML200HBA ML300HBA ODS/Pllot Assembly ...

  • Procom ML200TBA - page 21

    21 P ARTS LIST ML200HBA ML300HBA This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28-1 28-2 29 30 31 32 33 ML300HBA P ART NO. MB10003 MB09001 MB1 1 ...

Производитель Procom Категория Electric Heater

Документы, которые мы получаем от производителя устройства Procom ML200TBA мы можем разделить на несколько групп. Это в частности:
- технические чертежи Procom
- инструкции обслуживания ML200TBA
- паспорта изделия Procom
- информационные брошюры
- энергетические этикетки Procom ML200TBA
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Procom ML200TBA.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Procom ML200TBA, инструкции обслуживания, короткие инструкции или инструкции пользователя Procom ML200TBA. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Procom ML200TBA.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Procom ML200TBA, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Procom ML200TBA пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Procom ML200TBA.

Полная инструкция обслуживания Procom, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Procom ML200TBA - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Procom ML200TBA, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Procom ML200TBA, которое найдем в данном документе
3. Советы по использованию основных функций устройства Procom ML200TBA - которые должны облегчить нам первые шаги во время использования Procom ML200TBA
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Procom ML200TBA
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Procom ML200TBA в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Procom ML200TBA?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Procom ML200TBA, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Procom ML200TBA со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)