    P/N 5500305-20 Perle Gigabi t Media Converter Modul e Inst allation Guide C-1000-XX XXX Unmanaged M od ule CM-1000-X XXXX Man aged Mo dule C-1000-SFP Unmanag ed M odule CM-1000-SF P M anaged M odule ...

  • Perle Systems 5500305-20 - page 2

    Gigabit Medi a Converter Module – Installation Guide 2 Over vie w This docum ent contains instr uctions nec essar y for the instal lation and operatio n of the Per le Gigab it Ethernet Media Co nverter Module(s) th at are used in conj unction with a Perle MCR chas sis. The C-1000 are unm anaged m edia con verter m odules, and the CM-1000 are the ...

  • Perle Systems 5500305-20 - page 3

    Gigabit Medi a Converter Module – Installation Guide 3 Model Connector (xx) Mode - Distance Wavelength (TX/RX) C-1000-S1SC80U CM-1000- S1SC80U SC SM - 80 km/50 mi. 1510/1590 nm C-1000-S1SC80D CM-1000- S1SC80D SC SM - 80 km/50 mi. 1590/1510 nm C-1000-S2 xx 12 0 CM-1000- S2 xx 120 SC/ST/LC SM - 120 km/74.6mi 1550/1550 nm C-1000-S1SC120U CM-1000- S1 ...

  • Perle Systems 5500305-20 - page 4

    Gigabit Medi a Converter Module – Installation Guide 4 Inst allation This m odule com es equipped with a bank of DIP switches and jumpers for setting conf iguration T he defau lt switch s ettings (a ll switches in th e UP pos ition) will work for m ost installations. S ee the Operati ons section of this gu ide for m ore details. The f ollowing st ...

  • Perle Systems 5500305-20 - page 5

    Gigabit Medi a Converter Module – Installation Guide 5 DIP Switches DIP Switch Setti ngs Fiber Negotiation (Switch 1) Switch Posit ion Mo de Up (defau lt) Auto Down Off Auto : In this mode of operation the Medi a Converter will negoti ate Ethernet param eter s on bot h the copp er and the f iber c onnection. This will ensur e the m ost optim al c ...

  • Perle Systems 5500305-20 - page 6

    Gigabit Medi a Converter Module – Installation Guide 6 Link Mode (Switch 2) Switch Posit ion Mode Up (defau lt) Standard Mo de Down Sm art Link Pass -Through Mode Standard M ode : In th is m ode (if Fiber N egotiation is set to OFF ), the links on th e fiber a nd copper s ides can be broug ht up and down indep endentl y of eac h other. A loss of ...

  • Perle Systems 5500305-20 - page 7

    Gigabit Medi a Converter Module – Installation Guide 7 Pass-T hrough enab led, a los s of f iber link on eith er the trans m it or receive line will be pass ed throug h to the loca l copper connecti on thus notif ying the connec ted device . If the Media C onverter Module has been se t to Sm art Link Pass- Through m ode, the ef fec t will be the ...

  • Perle Systems 5500305-20 - page 8

    Gigabit Medi a Converter Module – Installation Guide 8 Duplex (Switch 4) Switch Posit ion Mo de Up (defau lt) Auto Down Half Auto: W hen Fiber Neg otiation h as been tur ned off (SW 1), the Media Con verter Mod ule will us e this Duplex setting f or its Ethernet param eter negotia tion on the co pper co nnection. I n the Auto position, t he Med i ...

  • Perle Systems 5500305-20 - page 9

    Gigabit Medi a Converter Module – Installation Guide 9 setting on the Media Co nve rter Modul e should m atch the capabilities of the far en d dev ice. Loopback (Switch 6) Switch Posit ion Mo de Up (defau lt) Disabled Down Enabled Disabled : T he loopbac k featur e is disa bled. This is t he norm al position for r egular oper atio n. The switc h ...

  • Perle Systems 5500305-20 - page 10

    Gigabit Medi a Converter Module – Installation Guide 10 Inst alling or Re placin g Media Converter M odule s Caution: O bserve electr ostatic d ischarge precautio ns when installing the Media Con verter Mo dule(s) into the Chas sis. Fail ure to observe this caution c ould r esult in dam age to the Modu le(s) and/or chass is. The Perle Me dia Conv ...

  • Perle Systems 5500305-20 - page 11

    Gigabit Medi a Converter Module – Installation Guide 11 6. Tighten the ca ptive re tainer s crew to ensure the Me dia Converter M odule is l ock ed in place. 7. Rem ove the dust cap f rom the fiber co nnector and connec t the fiber and copp er cabl es. Removing Media Co nvert Modules 1. Loosen the c aptive reta iner sc rew on the f ront of the Me ...

  • Perle Systems 5500305-20 - page 12

    Gigabit Medi a Converter Module – Installation Guide 12 Inst alling the Copper Cable • Locate a 1000Bas e-X com pliant s implex (1 s trand) fib er cable with appropr iate connec tors. • Conn ect the f iber cable fr om one Converter to the other Converter/s witch/fiber d evic e. Inst alling the Copper Cable • Locate 1000Bas e-TX compliant co ...

  • Perle Systems 5500305-20 - page 13

    Gigabit Medi a Converter Module – Installation Guide 13 Operation Status LED The Perle G igabit Medi a Conver ter Modu les have thr ee s ingle color status LEDs locat ed on the f ace plate of the m odule. PWR - Pow er/Test • On : Power is on , m odule is operat ing norm ally • Blinking slow ly : the m odule is in l oopback mode. • Blinking ...

  • Perle Systems 5500305-20 - page 14

    Gigabit Medi a Converter Module – Installation Guide 14 Other Fea tures Default Operating Mo de: In the defau lt operatin g m ode (all switches u p), the Me dia Converter M odule will auto-nego tiate on b oth the fib er and t he copper link s at the sam e tim e, thus achie ving the bes t end-to- end Ethernet opera ting p aram eters. If the f iber ...

  • Perle Systems 5500305-20 - page 15

    Gigabit Medi a Converter Module – Installation Guide 15 T roubleshootin g General • Ensure t he m odule is secur el y seated in the c hassis. T he P W R LED on the m odule s hould be o n solid. • Ensure both de vices on either end of the fiber ar e com patible. If using a s implex f iber connec tion, ens ure that you have both an Upstream (U ...

  • Perle Systems 5500305-20 - page 16

    Gigabit Medi a Converter Module – Installation Guide 16 Media Con verters sho uld be l it. Data sh ould pass through t he local converter, o ver the fiber c onnecti on to the rem ote c onverter. At the rem ote converter, the data w ill be loop ed back and pass ed through the f iber, once a gai n, to pass throu gh the local c onverter to the coppe ...

  • Perle Systems 5500305-20 - page 17

    Gigabit Medi a Converter Module – Installation Guide 17 T echnical Speci fications Power Inpu t/Consum ption 12V DC / 3.0 W Operating T emperatur e : 0 ° C to 50 ° C (32 ° F to 122 ° F) Storage Tem perature: -25 ° C t o 70 ° C (-1 3 ° F to 1 58 ° F) Operating Hu midit y: 5% to 90% non-con densing Storage Hum idity 5% to 95% non-con densin ...

  • Perle Systems 5500305-20 - page 18

    Gigabit Medi a Converter Module – Installation Guide 18 C-1000-S2 xx 70 CM-1000- S2 xx 70 SM TX : 1550 RX: 1550 Min: -0 Max: 5 Min: -23 Max: -3 23 C-1000-S1SC80U CM-1000- S1SC80U SM TX: 1510 RX: 1590 Min: -2 Max: 3 Min: -26 Max: -3 24 C-1000-S1SC80D CM-1000- S1SC80D SM TX: 1590 RX: 1510 Min: -2 Max: 3 Min: -26 Max: -3 24 C-1000-S2 xx 12 0 CM-1000 ...

  • Perle Systems 5500305-20 - page 19

    Gigabit Medi a Converter Module – Installation Guide 19 Complian ce Inf ormation FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection again st harmful interference when the equipment is operated in a commercial envir ...

  • Perle Systems 5500305-20 - page 20

    Gigabit Medi a Converter Module – Installation Guide 20 W arr ant y / Registrati on Perle’s stan dard Lifetim e War ranty pro vides custom ers with r eturn to factor y repairs for Perle produc ts that f ail under th e condit ions of the warrant y coverag e. Det ails can be f ound at: http://www.perle.com/su pport_services/warranty .shtml Contac ...

Производитель Perle Systems Категория Switch

Документы, которые мы получаем от производителя устройства Perle Systems 5500305-20 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Perle Systems
- инструкции обслуживания 5500305-20
- паспорта изделия Perle Systems
- информационные брошюры
- энергетические этикетки Perle Systems 5500305-20
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Perle Systems 5500305-20.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Perle Systems 5500305-20, инструкции обслуживания, короткие инструкции или инструкции пользователя Perle Systems 5500305-20. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Perle Systems 5500305-20.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Perle Systems 5500305-20, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Perle Systems 5500305-20 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Perle Systems 5500305-20.

Полная инструкция обслуживания Perle Systems, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Perle Systems 5500305-20 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Perle Systems 5500305-20, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Perle Systems 5500305-20, которое найдем в данном документе
3. Советы по использованию основных функций устройства Perle Systems 5500305-20 - которые должны облегчить нам первые шаги во время использования Perle Systems 5500305-20
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Perle Systems 5500305-20
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Perle Systems 5500305-20 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Perle Systems 5500305-20?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Perle Systems 5500305-20, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Perle Systems 5500305-20 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)