    Oct. 2005, Rev. 9 UL325 COMPLIANCE REQUIRES THE USE OF CONT ACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMA TIC OR REMOTEL Y -CONTROLLED GA TE OPERA TORS. OPERATOR SPECIALTY COMPANY, INC. CASNOVIA, MI 49318 • U.S.A. ® SLR • SLC • SLD INST ALL AT ION GUIDE ...

  • Cosco SLD - page 2

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 2 - TABLE OF CONTENTS PRE-INST ALLA TION INFORMA TION Gate Operator Classifications ......................................................................................................................................................... 3 Safety Information and Warnings ............................ ...

  • Cosco SLD - page 3

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 3 - Read the following before beginning to install OSCO slide gate operators: 1. Read the yellow “Safety Instructions” brochure enclosed with the packet of information. If you do not have one, please call OSCO at 1-800-333-1717 to request one. Read and follow all instructions. 2. All electrical ...

  • Cosco SLD - page 4

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 4 - 10-04-6 WIRING SPECIFICATIONS 1. Select from the chart at the bottom of this page corre- sponding to the model, voltage and horsepower rating of your operator . 2. The distance shown on the chart is measured in feet from the operator to the power source. DO NOT EXCEED THE MAXIMUM DIST ANCE . The ...

  • Cosco SLD - page 5

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 5 - PAD MOUNTING INSTRUCTIONS FOR MODELS SLR, SLC & SLD Before installing, make sure the gate rolls or slides freely , and that all exposed rollers are properly covered. The gate must be covered with fabric with openings no larger than 2 1/4” in size, to a minimum height of 48 inches above gro ...

  • Cosco SLD - page 6

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 6 - GATE BRACKET AND CHAIN ASSEMBLY INSTRUCTIONS Assemble a gate bracket (1) to the front edge of the gate, using two U-bolts (2), and mounting hardware (3). Before tightening down completely , be sure the bracket is p arallel to the gate. T ighten the U-bolt hardware the rest of the way , then scre ...

  • Cosco SLD - page 7

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 7 - VENT PLUG INSTALLATION Gear reducers used in OSCO gate operators will have solid plugs installed prior to shipment in order to keep the oil inside fro m spilling out during shipping. A vent plug has been provided to replace this plug during installation. This plug will look similar to the ones s ...

  • Cosco SLD - page 8

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 8 - ELECTRICAL CONNECTION AND ADJUSTMENTS All OSCO gate operators are supplied with a power disconnect switch to turn on and off the power supply available to the operator . Incoming power should be brought into the operator and connected to the labeled pigtails in the disconnect box following wirin ...

  • Cosco SLD - page 9

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 9 - Auto Close Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to close automatically , provided no open, reversing or obstruction signals are present from the fully-open position. This timer is adjustable from 0 to 124 seconds. This feature is turned on or off us ...

  • Cosco SLD - page 10

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 10 - Y ou must follow all required safety precautions and instructions at all times. Review the safety brochure included with the operator . If any pages are missing or unreadable, cont act OSCO at 1-800-333-1717 to request additional copies. Never connect a button st ation within reach of the gate ...

  • Cosco SLD - page 11

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 11 - CURRENT SENSING ADJUSTMENTS Because gates vary in construction and may have different force requirements in the open and close directions to move, the OSCO control board has separate Multi-turn potentiometers for adjusting in both directions independently . The adjustment should be set light en ...

  • Cosco SLD - page 12

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 12 - ONBOARD L.E.D. INDICATOR DESCRIPTIONS Control Board L.E.D. Indicators: OPEN This indicator is lit when an open signal is present. This signal can come from such devices as button stations, radio receivers, keypads and telephone entry systems. CLOSE This indicator is lit when a closed signal is ...

  • Cosco SLD - page 13

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 13 - IMPORTANT NOTES FOR INSTALLATION OF MASTER/SLAVE APPLICATIONS When setting up Master/Slave gate operators, it is best to make adjustments and run each operator individually . T o do this, simply: a. Set Dip Switch #4 to proper hand of operation (right-hand or left-hand) b. Set Dip Switch #8 as ...

  • Cosco SLD - page 14

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 14 - CHARGER BOARD SLEEP MODE When primary AC power is not available, the operator will continue to operate in battery only mode if the charger board is set in its RUN mode ( see Battery Backup Charger Configuration ). Accessories wired into the operator will continue to draw power , even when the o ...

  • Cosco SLD - page 15

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 15 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS ...

  • Cosco SLD - page 16

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 16 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS ...

  • Cosco SLD - page 17

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 17 - CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS ...

  • Cosco SLD - page 18

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 18 - 12-06-12 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS AC MODELS ONL Y ...

  • Cosco SLD - page 19

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 19 - LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 18 for details. ...

  • Cosco SLD - page 20

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 20 - EDGE LAYOUT ILLUSTRATION #1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details. ...

  • Cosco SLD - page 21

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 21 - EDGE LAYOUT ILLUSTRATION #2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 17 for details. ...

  • Cosco SLD - page 22

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 22 - PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 17 for details. ...

  • Cosco SLD - page 23

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 23 - PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 15-18 for additional details. ...

  • Cosco SLD - page 24

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 24 - TRACK GATE ILLUSTRATION ...

  • Cosco SLD - page 25

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 25 - TROUBLESHOOTING Operator fails to start: A . If the operator has been running a large number of cycles, the motor may have gotten hot and tripped the overload. Allow the motor to cool down and the overload will reset automatically . B . Make sure you have power at the master distribution panel ...

  • Cosco SLD - page 26

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 26 - MODEL SLR MECHANICAL PARTS EXPLODED VIEW 10-04-6 ...

  • Cosco SLD - page 27

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 27 - MODEL SLR MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset Button 2500-2241 Plunger Extension only 2200-790 Lock for Cover , with Keys 2 21 10-796 Main Frame Assembly 2 A 2100-2006 Lock T ab Bracket 3 2100-2055 ...

  • Cosco SLD - page 28

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 28 - MODEL SLC MECHANICAL PARTS EXPLODED VIEW 10-04-6 ...

  • Cosco SLD - page 29

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 29 - MODEL SLC MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset Button 2500-2241 Plunger Extension only 2200-790 Lock for Cover , with Keys 2 21 10-796 Main Frame Assembly 2A 2100-2006 Lock T ab Bracket 3 2100-2055 ...

  • Cosco SLD - page 30

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 30 - 10-04-6 MODELS SLR • SLC CONTROL BOX PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778-PL T Control Box Wrapper 2 2100-1762 T erminal S trip Bracket, output side 3 2100-1761 T erminal S trip Bracket, input side 4 2300-735 Heyco Bushing, 1.09 diameter 5 2200-122 Heyco Bushing, .87 diameter ...

  • Cosco SLD - page 31

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 31 - MODEL SLD MECHANICAL PARTS EXPLODED VIEW 10-04-6 ...

  • Cosco SLD - page 32

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 32 - MODEL SLD MECHANICAL PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2300-907 Operator Cover 2510-354 Plunger Reset Assembly 2500-2240 Plunger Reset Button 2500-2241 Plunger Extension only 2200-790 Lock for Cover , with Keys 2 21 10-796 Main Frame Assembly 2 A 2100-2006 Lock T ab Bracket 3 2100-2055 ...

  • Cosco SLD - page 33

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 33 - 10-04-6 MODEL SLD CONTROL BOX PARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778-PL T Control Box Wrapper 3 2100-1762 T erminal S trip Bracket, output side 4 2100-1761 T erminal S trip Bracket, input side 5 2200-122 Heyco Bushing, .87 diameter 6 2500-1948 Control Board Standoff 7 2510-269 Con ...

  • Cosco SLD - page 34

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 34 - BATTERY MAINTENANCE The gel-cell batteries in this operator require no routine maintenance. For assured continued performance, they should be replaced every year . If power is to be removed for one week or more, disconnect the negative wire from the batteries as this will prevent deep dischargi ...

  • Cosco SLD - page 35

    MA TERIAL SAFETY DA T A SHEET MOBIL SHC 634 1 . PRODUCT AND COMP ANY IDENTIFICA TION PRODUCT NAME: MOBIL SHC 634 SUPPLIER: EXXONMOBIL CORPORA TION 3225 GALLOWS RD. F AIRF AX, V A 22037 24 - Hour Health and Safety Emergency (call collect): 609-737-441 1 24 - Hour T ransport ation Emergency (Primary) CHEMTREC: 800-424-9300 Product and MSDS Informatio ...

  • Cosco SLD - page 36

    sso 3 Imperial Oil MA TERIAL SAFETY DA T A SHEET Date Prepared: June 12, 1997 Supersedes: February 02, 1996 MSDS Number: 08068 Cette fiche signaletique ast aussi disponible en francais 1. PRODUCT INFORMA TION Product Identifier: ESSO GEAR OIL GX 75W-90 Application and Use: Transmission adn gear lubricant. Product Description: Mixture of paraffinic ...

  • Cosco SLD - page 37

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 37 - ...

  • Cosco SLD - page 38

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 38 - PREVENTATIVE MAINTENANCE GENERAL: OSCO gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance. T o ensure that your unit is ready for operation at all times--and to preclude serious damage or failur ...

  • Cosco SLD - page 39

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 39 - This page intentionally left blank. ...

  • Cosco SLD - page 40

    SLR • SLC • SLD OPERATOR INSTALLATION GUIDE - 40 - By signing this installation checklist, I/we hereby certify that each item listed and checked above has been covered by the installer and is clearly understood by the customer . ______________________________________________ _____________________________ Customer Signature Date ________________ ...

Производитель Cosco Категория Safety Gate

Документы, которые мы получаем от производителя устройства Cosco SLD мы можем разделить на несколько групп. Это в частности:
- технические чертежи Cosco
- инструкции обслуживания SLD
- паспорта изделия Cosco
- информационные брошюры
- энергетические этикетки Cosco SLD
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Cosco SLD.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Cosco SLD, инструкции обслуживания, короткие инструкции или инструкции пользователя Cosco SLD. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Cosco SLD.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Cosco SLD, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Cosco SLD пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Cosco SLD.

Полная инструкция обслуживания Cosco, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Cosco SLD - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Cosco SLD, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Cosco SLD, которое найдем в данном документе
3. Советы по использованию основных функций устройства Cosco SLD - которые должны облегчить нам первые шаги во время использования Cosco SLD
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Cosco SLD
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Cosco SLD в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Cosco SLD?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Cosco SLD, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Cosco SLD со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)