Инструкция обслуживания Goodman Mfg IO-354B

27 страниц 0.59 mb
Скачать

Перейти на страницу of 27

Summary
  • Goodman Mfg IO-354B - page 1

    All information contained herein is subject to change without notice. I NST ALLA TION I NSTRUCTIONS F OR L IGHT C OMMERCIAL S ELF -C ONT AINED P ACKAGED H EA TING & C OOLING U NIT 3 T ON - 6 T ON CPC/CPH S ERIES Goodman Manufacturing Company , L.P . IO-354B 5151 Felipe, Suite 500, Houston, TX 77056 04/09 www .goodmanmfg.com www .amana-hac.com ? ...

  • Goodman Mfg IO-354B - page 2

    2 REPLACEMENT PARTS O RDERING P ARTS When reporting shortages or damages, or ordering rep air part s, give the complete unit model and serial numbers as stamped on the unit’ s nameplate. Replacement parts for this appliance are available through your contractor or local distributor . For the location of your nearest distributor , consult the whit ...

  • Goodman Mfg IO-354B - page 3

    3 T HIS UNIT MU ST NOT BE USED AS A “ CONST RUC TION HEATE R ” DURING THE FINISHING PHAS ES OF CONST RUC TION ON A NEW STRUCT UR E . T HIS TYPE OF USE MA Y RESU LT IN PREMAT UR E FAILURE OF THE UNIT DUE TO EXT REME LY LOW RETURN AIR TEMP ERAT URES AND EXPO SURE TO CORR OSIVE OR VER Y DIRT Y ATMO SPHE RES . W ARNING H I G H V O LTA G E ! D ISCON ...

  • Goodman Mfg IO-354B - page 4

    4 NOTE: When inspecting the unit for transportation damage, remove all packaging materials. Recycle or dispose of the packaging material according to local codes. P RE -I NSTALLATION C HECKS Carefully read all instructions for the installation prior to in- stalling unit. Ensure each step or procedure is understood and any special considerations are ...

  • Goodman Mfg IO-354B - page 5

    5 T O PRE VENT PO SSIBLE EQ U IPM ENT DAMAGE , PROP ERTY DAMAG E , PERSO NAL INJURY OR DEATH , THE FOLLOW I NG BULLET PO I NTS MU ST BE OBSE RVED WHEN INSTALLING THE UNIT . W ARNING • Sufficient structural support must be determined prior to locating and mounting the curb and package unit. • Ductwork must be constructed using industry guideline ...

  • Goodman Mfg IO-354B - page 6

    6 P ROTRUSION Inspect curb to ensure that none of the utility services (elec- tric) routed through the curb protrude above the curb. I F PROT RUSIO NS EXI ST , DO NO ATTEMPT TO SET UNIT ON CURB . CAUTION ROOF TOP DUCT CONNECTIONS Install all duct connections on the unit before placing the unit on rooftop. H ORIZONTAL D ISCHARGE For horizontal disch ...

  • Goodman Mfg IO-354B - page 7

    7 Lower unit carefully onto roof mounting curb. While rigging unit, center of gravity will cause condenser end to be lower than supply air end. T o assist in determining rigging requirements, unit weights are shown as follows: A B C D CG SUPP LY RETURN EV APORA TOR COI L CONDENSER COIL COMPRESSOR Y X CORNER & CENTER OF GRAVITY LOCATIONS AB CD C ...

  • Goodman Mfg IO-354B - page 8

    8 T O PRE VENT SEVE RE DAMAG E TO THE BOTTOM OF THE UNIT , DO NOT FORK LIFT UNIT AFTER WOOD STRUT S HAVE BEEN REMOV ED . CAUTION Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a r ...

  • Goodman Mfg IO-354B - page 9

    9 LOW VOLT AGE BLOCK MA IN PO WER LOW VO L T AGE ENTRANCE POWER THRU THE CURB CONTROL BOX F AILU RE OF UNIT DUE TO OPERATION ON IMP ROPER LINE VOLTAGE OR WITH EXC ESSI VE PHAS E UNBAL ANC E CONSTITUTES PRODUCT ABUSE AND WILL VO I D YO U R WARRANT Y AND MA Y CAUSE SEVE RE DAMAG E TO THE UNIT ELECTR ICAL COMPONE NTS . W ARNING Areas Without Convenien ...

  • Goodman Mfg IO-354B - page 10

    10 CIRCULA TING AIR AND FIL TERS D UCTWORK The supply duct from the unit through a wall may be installed without clearance. However , minimum unit clearances must be maintained (see “Clearances” section). The supply duct should be provided with an access panel large enough to inspect the air chamber downstream of the heat exchanger . A cover sh ...

  • Goodman Mfg IO-354B - page 11

    11 T OOLS R EQUIRED Refrigeration gauge and manifold V oltmeter Clamp-on ammeter Ohmmeter T est lead (Minimum #16 AWG with insulated alligator clips) Air temperature measuring device General refrigeration mechanics’ tools T EMPORARY H EATING O R C OOLING If the unit is to be used for temporary heating or cooling, a “S tartup, Adjustments, and C ...

  • Goodman Mfg IO-354B - page 12

    12 t = Span length, inches C = Center distance, inches D = Larger sheave diameter , inches d = Smaller sheave diameter , inches h = Deflection height, inches DRIVE BELT TENSION ADJUSTMENT BE L T DR IV E Use d Ne w A , A X Sta nda r d 3.0 to 4 .0 4. 2 ± .5 5. 5 ± . 5 0. 313 DE F L ECT I O N (in) DE F L ECT I O N FO RCE ( lbs) SH EA VE DIAM E T E R ...

  • Goodman Mfg IO-354B - page 13

    13 de-energized (heating) position. After giving the unit time to settle out, make sure the unit is supplying heated air . 12. If the outdoor ambient is above 80°F , the unit may trip on its high pressure cut out when on heating. The compressor should stop. The heating cycle must be thoroughly checked, so postpone the test to another day when cond ...

  • Goodman Mfg IO-354B - page 14

    14 E V A P O R A T O R COOLI NG SERV I C E VALVE SERVICE PO RT REVERSI NG VALVE C O N D E N S E R SERV I C E PORT COM PRES S OR SERV I C E PORT ACCUMULAT O R EXPANSION D EVI C E CH ECK VALVE ORI FI CE SERV I C E VALVE CHECK VA LVE ORIFI CE IN DO O R COI L DI ST RIBUTOR OUTD OOR CO I L E V A P O R A T O R HEAT I NG SERV I C E VALVE SERV I C E PORT R ...

  • Goodman Mfg IO-354B - page 15

    15 DRIVE ADJUSTMENTS MOTOR SHEA VE ADJUSTMENTS V L , V M , & 2 VP V ARIABLE P ITCH K EY T YPE M OTOR S HEAVES The driving and driven motor sheaves should be in align- ment with each other and the shaft s parallel. V L & V M S HEAVES A DJUSTMENT 1. Loosen set screw “B” using a 5/32" Allen key . 2. Making half or full turns from clos ...

  • Goodman Mfg IO-354B - page 16

    16 L UBRICATION The fan shaft bearings, the 1 to 2 HP supply fan motors the condenser fan motors and compressors are permanently lu- bricated. F UNCTIONAL P ARTS Refer to the unit Parts Catalog for a list of functional p arts. Parts are available from your distributor . SERVICE THE FOLLOWING INFORMA TION IS FOR USE BY QUALI- FIED SERVICE AGENCY ONL ...

  • Goodman Mfg IO-354B - page 17

    17 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD DOWN SHOT AND HORIZONT AL SPE ED T A P E X TE RNAL S T ATIC PR E SS U R E ( ESP ) in w . c . S T A N DARD CFM A M PS WA T TS R PM 0. 10 1287 1 .66 3 50 770 0. 20 1233 1 .63 3 42 815 0. 30 1176 1 .59 3 32 858 0. 40 1107 1 .55 3 20 891 0. 50 1044 1 .51 3 12 924 0. 60 965 1 .45 2 96 957 0. ...

  • Goodman Mfg IO-354B - page 18

    18 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD DOWN SHOT AND HORIZONT AL SPE ED T A P E X TE RNAL S T ATIC PR E SS U R E ( ESP ) in w . c . S T A N DARD CFM A M PS WA T TS R PM 0. 10 1602 2 .48 5 28 835 0. 20 1538 2 .37 5 06 878 0. 30 1474 2 .26 4 84 921 0. 40 1390 2 .15 4 60 950 0. 50 1306 2 .04 4 36 979 0. 10 1805 2 .84 6 20 935 0 ...

  • Goodman Mfg IO-354B - page 19

    19 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD CPC/H060 DOWN SHOT SP EED TAP E XTE RNAL S T ATIC PR E SSU R E ( ESP ) in w . c . S T ANDAR D CF M AM P S W ATTS R P M 0. 10 1 334 1.6 5 180 62 7 0. 20 1 286 1.7 5 192 66 5 0. 30 1 212 1.8 3 202 71 5 0. 40 1 144 1.9 4 216 75 9 0. 50 1 077 1.9 9 222 79 2 0. 60 1 039 2.1 0 238 83 0 0. 70 ...

  • Goodman Mfg IO-354B - page 20

    20 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD CPC/H060 HORIZONT AL SP EED TAP E XTE RNAL S T AT IC PR E SSU R E ( ESP ) in w . c . STANDAR D CF M AMP S W AT T S R P M 0. 10 1 355 1.57 174 59 9 0. 20 1 281 1.66 182 65 1 0. 30 1 235 1.76 196 69 3 0. 40 1 168 1.81 202 72 6 0. 50 1 118 1.94 218 77 5 0. 60 1 049 2.03 232 81 9 0. 70 9 82 ...

  • Goodman Mfg IO-354B - page 21

    21 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE ST ANDARD DOWN SHOT CP C/H0 36 ST AND AR D BEL T DR I VE DO W N SHO T CFM BHP C FM BHP CFM BH P CF M B HP C F M BHP CFM BH P 0. 2 1 42 4 0. 3 0 1 2 39 0. 2 3 0. 4 152 0 0. 39 1 292 0.2 9 10 73 0 . 22 77 9 0 .14 0. 6 14 39 0 .4 0 119 2 0. 30 9 44 0. 2 1 6 19 0 .12 0. 8 1 350 0.4 2 11 01 0 .31 8 6 4 ...

  • Goodman Mfg IO-354B - page 22

    22 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE HIGH ST A TIC DOWN SHOT CP C0 3 6 H IG H S T ATI C BEL T D RI V E DO W N SHOT CFM BHP C FM BHP CFM BH P CFM B HP C FM BHP CFM BH P 0. 6 16 9 2 0 . 54 1 44 9 0. 4 1 1 1 73 0. 2 9 0. 8 167 8 0. 58 1 397 0.4 4 11 07 0 . 31 85 4 0 .21 1. 0 16 81 0 .6 5 138 1 0. 49 1 078 0.3 4 7 94 0 .2 2 1. 2 1 681 0. ...

  • Goodman Mfg IO-354B - page 23

    23 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE ST ANDARD HORIZONT AL CP C/H036 STAND ARD BE L T DRI VE HORI Z O NT AL CFM BHP C FM BHP CF M BH P CF M B HP C FM BHP CFM B H P 0. 2 1 65 8 0. 3 5 1 4 89 0. 2 8 0. 4 1 560 0.3 6 13 39 0 . 28 112 9 0 .21 0. 6 16 82 0 .47 143 6 0. 36 1 196 0.2 7 9 49 0 . 19 0. 8 1 581 0.5 0 13 54 0 .38 109 6 0. 2 8 8 ...

  • Goodman Mfg IO-354B - page 24

    24 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE HIGH ST A TIC HORIZONT AL CP C/H036 HI G H S T AT I C BE L T DRI V E HORIZO NTAL CFM BHP C FM BHP CFM BH P CF M B HP C F M BH P CFM BH P 0. 6 1 74 2 0. 5 0 1 4 31 0. 3 6 0. 8 16 2 6 0 . 52 1 35 7 0. 3 9 1 0 78 0. 2 7 1 161 1 0. 56 1 315 0.4 2 10 11 0 .28 1. 2 16 05 0 .6 2 129 9 0. 46 9 76 0. 3 1 1 ...

  • Goodman Mfg IO-354B - page 25

    25 APPENDIX B ELECTRICAL DA T A MIN. M AX . Q TY RLA LRA QTY H P R LA H P FLA 20 8 /2 3 0- 60 - 1 18 7 2 53 1 1 6. 6 7 7 9 1 1 / 4 1. 4 0 DD S T D S T A T I C 1 / 3 2. 5 DD S TD S TA T I C 1 / 3 2.5 BD ST D ST A TI C 1.0 3 .8 46 0- 60 -3 41 4 5 06 1 5 .7 7 3 8. 0 1 1 / 4 0. 8 0 BD ST D S T A T I C 1 . 0 1. 9 57 5- 60 -3 51 8 6 33 1 3. 8 3 7. 0 1 1 ...

  • Goodman Mfg IO-354B - page 26

    26 A TTENTION INST ALLING PERSONNEL Use only the heater kit specified for each model as dict ated by the table above. APPENDIX B ELECTRICAL DA T A UNIT HE AT ER KIT MO DE L NU M B E R MI N I MU M C F M EH K *-1 0 1 2 5 0 EH K *-1 5 1 2 5 0 EH K *-1 0 1 3 0 0 EH K *-1 5 1 4 0 0 EH K *-1 8 1 4 0 0 EH K *-1 0 1 7 0 0 EH K *-1 5 1 7 0 0 EH K *-2 0 1 8 ...

  • Goodman Mfg IO-354B - page 27

    27 APPENDIX C UNIT DIMENSIONS HORIZONTAL DISCHARGE VERTICAL DISCHARGE NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings. Install with insulation facing up, using the longer screws provided in the literature package. RETURN SUPPL Y 12” 17” 7 3/ 8” 11 ? ...

Производитель Goodman Mfg Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Goodman Mfg IO-354B мы можем разделить на несколько групп. Это в частности:
- технические чертежи Goodman Mfg
- инструкции обслуживания IO-354B
- паспорта изделия Goodman Mfg
- информационные брошюры
- энергетические этикетки Goodman Mfg IO-354B
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Goodman Mfg IO-354B.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Goodman Mfg IO-354B, инструкции обслуживания, короткие инструкции или инструкции пользователя Goodman Mfg IO-354B. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Goodman Mfg IO-354B.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Goodman Mfg IO-354B, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Goodman Mfg IO-354B пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Goodman Mfg IO-354B.

Полная инструкция обслуживания Goodman Mfg, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Goodman Mfg IO-354B - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Goodman Mfg IO-354B, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Goodman Mfg IO-354B, которое найдем в данном документе
3. Советы по использованию основных функций устройства Goodman Mfg IO-354B - которые должны облегчить нам первые шаги во время использования Goodman Mfg IO-354B
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Goodman Mfg IO-354B
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Goodman Mfg IO-354B в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Goodman Mfg IO-354B?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Goodman Mfg IO-354B, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Goodman Mfg IO-354B со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)