Инструкция обслуживания Omega Engineering OS137

20 страниц 0.38 mb
Скачать

Перейти на страницу of 20

Summary
  • Omega Engineering OS137 - page 1

    OS137 SERIES Miniature Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at ...

  • Omega Engineering OS137 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega Engineering OS137 - page 3

    i OS137 Series Miniature Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution & Safety Information ...................................................................... iii Safety W arnings and IEC Symbols .............................................................. iii Section 1 Introduction ........ ...

  • Omega Engineering OS137 - page 4

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter ii T able of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 2-2 Alarm Output W iring Diagram .................................................... 2 3-1 Optical Field of V iew .................... ...

  • Omega Engineering OS137 - page 5

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1). There is no user r eplaceable fuse in this product. The output terminals ...

  • Omega Engineering OS137 - page 6

    1 SECTION 1 - INTRODUCTION The OS137 Series is a precision, miniatur e infrared transmitter . It measures temperature via non-contact, and pr ovides an analog output proportional to the measured temperatur e. The OS137 Series is offered in thr ee temperature ranges: 0 to 100ºC (32 to 212ºF), -18 to 260ºC (0 to 500ºF) and -18 to 538ºC (0 to 100 ...

  • Omega Engineering OS137 - page 7

    2 2 - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -MVF : 10 mV/ºF output The following table lists the optional accessories: 2.2 – Electrical Connection The shielded cable provides the power and output connections. Fig 2-1 shows the wiring diag ...

  • Omega Engineering OS137 - page 8

    3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sure the following check list is met:  The power and output connections are made (Fig 2-1).  The target is lar ger than the optical field of view of the transmitter (Fig 3-1).  Use the Laser Sighting accessory (optional), to ...

  • Omega Engineering OS137 - page 9

    Operation 3 4 3.2 – Ambient T emperature The transmitter can operate in an ambient temperature of 0 to 70°C (32 to 158°F) without any water cool jacket. It can operate from 0 to 200°C (32 to 392°F) with the water cool jacket accessory , OS137-WC (Fig 3-6 & 3-7). It can operate up to 1 10°C (230°F) with air cooling. There is a warm up pe ...

  • Omega Engineering OS137 - page 10

    Figure 3-4. Air Purge Collar, OS137-AP Figure 3-5. Stainless Steel Housing Figure 3-6. Water/Air Cool Jacket, OS137-WC Operation 3 5 LIGHT DIAMOND KNURL 2.5 (0.1) WIDE DIMENSIONS mm (in) 1-20 UNEF 127 (5.0) 1.83 m (6 ft) 42.4 (1.67) 25.4 (1.0) DIMENSIONS mm (in) 128.6 (5.062) 7.9 (0.312) 41.2 (1.625) 1-20 UNEF 9.5 (3/8) 1-20 UNEF BUIL T -IN AIR PUR ...

  • Omega Engineering OS137 - page 11

    3.4 Alarm Setting The unit provides 0-100% alarm setpoint adjustment. Her e is an example of an alarm setting: • An OS137-3-MA (4/20 mA output), the alarm is to be set at 204°C (400°F) temperature. • Connect the alarm output as shown in Fig. 2-2. • Remove the End Cap to get to the Alarm Switch and the Alarm Adjust (Fig. 3-2). • Set the Sl ...

  • Omega Engineering OS137 - page 12

    SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arnings and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED IN THIS GUIDE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE. • DO NOT LOOK A T THE LASER BE ...

  • Omega Engineering OS137 - page 13

    8 Figure 4-1. Laser Sighting Accessory, OS137-LS Figure 4-2. Laser Warning Label LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 22.2 (0.875) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS137 Dimensions mm (in) OUTPUT <1 mW, WAVELENGTH 630-670 nm, CLASS II (2) LASER PRODUCT. COMPLIES WITH ...

  • Omega Engineering OS137 - page 14

    9 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS137-1 0 to 100ºC (32 to 212ºF) OS137-2 -18 to 260ºC (0 to 500ºF) OS137-3 -18 to 538°C (0 to 1000°F) Accuracy: @22ºC (72ºF) ambient 1.5% of Rdg or 2.0ºC (3.5ºF) whichever is greater Emissivity of 0.95 or greater Repeatability: 1% of Rdg or 1.0ºC (2.0ºF) whichever is grea ...

  • Omega Engineering OS137 - page 15

    10 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (red) Operating Distance: Up to 9.1 m (30 ft) Max. Laser Power Output: Less than 1 mW @ 22ºC (72°F) ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 mm Beam Di ...

  • Omega Engineering OS137 - page 16

    Emissivity T able 6 11 Material Emissivity ( ε ) Aluminum – pure highly polished plate . . . . . . . . . . . . . . . . . . . . . . . . 0.04 to 0.06 Aluminum – heavily oxidized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 to 0.31 Aluminum – commercial sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering OS137 - page 17

    Emissivity Table 6 12 Material Emissivity ( ε ) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.96 Asphalt, tar , pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.95 to 1.00 Brick – red and rough . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering OS137 - page 18

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter 6 13 NOTES: ...

  • Omega Engineering OS137 - page 19

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from d ate of p ur ch as e. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega Engineering OS137 - page 20

    M4015/0108 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Con ...

Производитель Omega Engineering Категория Weather Radio

Документы, которые мы получаем от производителя устройства Omega Engineering OS137 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Omega Engineering
- инструкции обслуживания OS137
- паспорта изделия Omega Engineering
- информационные брошюры
- энергетические этикетки Omega Engineering OS137
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Omega Engineering OS137.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Omega Engineering OS137, инструкции обслуживания, короткие инструкции или инструкции пользователя Omega Engineering OS137. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Omega Engineering OS137.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Omega Engineering OS137, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Omega Engineering OS137 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Omega Engineering OS137.

Полная инструкция обслуживания Omega Engineering, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Omega Engineering OS137 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Omega Engineering OS137, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Omega Engineering OS137, которое найдем в данном документе
3. Советы по использованию основных функций устройства Omega Engineering OS137 - которые должны облегчить нам первые шаги во время использования Omega Engineering OS137
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Omega Engineering OS137
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Omega Engineering OS137 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Omega Engineering OS137?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Omega Engineering OS137, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Omega Engineering OS137 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)