    THERMOST A TICALL Y CONTROLLED W ALL MOUNTED UNVENTED GAS HEA TER WIR1-WIR2 (Equipped with Pilot Light Safety System) W ARNING: If the infor mation in this manual is not followed exactly , a fire or explosion may result caus- ing property damage, personal injur y , or loss of life. - Do not store or use gasoline or other flammable vapors and liquid ...

  • DeLonghi WIR2 - page 2

    SAFETY INFORMA TION W ARNING: Carbon monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly . Get fresh air at once! Have heater ser viced. Some people are more affect- ed by carbon monoxide than others. These include preg ...

  • DeLonghi WIR2 - page 3

    1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Place propane/LP sup- ply tank(s) outdoors. 3. This heater shall not be installed in a bed- room or bathroom. 4. If you smell gas - Shut off ...

  • DeLonghi WIR2 - page 4

    PRODUCT FEA TURES Safety device This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air . Piezo ignition system This heater has a piezo ignitor . This system requires no matches, batterie ...

  • DeLonghi WIR2 - page 5

    Confined and Unconfined Space The National Fuel gas Code , ANSI Z223.1/NFP A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4,8 m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per ...

  • DeLonghi WIR2 - page 6

    If the actual Btu/Hr used is less than the max- imum Btu/Hr the space can support, the space is an unconfined space. Y ou will need no addi- tional fresh air ventilation. VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pr ...

  • DeLonghi WIR2 - page 7

    INST ALLA TION CHECK GAS TYPE Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater . Call dealer where you bought heater for proper type heater . INST ALLA TION ITEMS Before installing heater , make sure you have the items listed below . • for propane/LP gas, external regu ...

  • DeLonghi WIR2 - page 8

    INST ALLA TION • Sign in the wall to make the hole “A”. • Drill the wall by using a 1/4” drill. • Insert the two plastic expansion anchors supplied in the installation kit, in the holes. • Insert two of the four screws supplied in the holes letting them stick out from the wall for at least 5 mm (see fig. aside) • Hook the appliance ...

  • DeLonghi WIR2 - page 9

    Installation must include equipment shutoff valve, union, and plugged 1/8” NPT tap. Locate NPT tap within reach for test gauge hook up. NTP tap must be upstream from heater (see fig 7) IMPORT ANT : install an equipment shutof f valve in accessible location. The equipment shutoff valve is for tur ning on or shutting off the gas to the appliance. A ...

  • DeLonghi WIR2 - page 10

    T est pressures equal or less than 1/2 PSIG (3,5 Kpa) 1. Close equipment shutoff valve (see figure 8). 2. Pressurize supply piping system by either opening propane/LP supply tank valve located on or near gas meter for natural gas, or using compressed air . 3. Check all joints from gas meter for natural gas (see figure B) or propane/LP supply tank f ...

  • DeLonghi WIR2 - page 11

    11 OPERA TING HEA TER A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. Before lighting smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS. • Do ...

  • DeLonghi WIR2 - page 12

    The thermostatic control used on this model turn on and off the bur ner . The thermostat used on this heater senses the room temperature. At times the room may exceed the set tempera- ture. If so, the burner will shut of f. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any 2 comf ...

  • DeLonghi WIR2 - page 13

    BURNER FLAME P A TTERN Figure 15 shows a correct bur ner flame pat- tern. Figure 16 shows a incorrect burner flame pattern. If burner flame pattern is incorrect, as shown in figure 16 • turn heater off (see to turn off gas to appli- ance, page 12) • see troubleshooting, pages 16 through 18 13 correct burner fig. 16 fig. 15 incorrect burner WIR ...

  • DeLonghi WIR2 - page 14

    CLEANING AND MAINTENANCE ODS/PILOT AND BURNER •U se a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CLEANING BURNER PILOT AIR INLET The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet ho ...

  • DeLonghi WIR2 - page 15

    15 SPECIFICA TION This heater is equipped with an oxygen deple- tion safety system and safety shut-off system. APPLIANCE DIMENSIONS Width: 15.75 inches Height: 29.14 inches Depth: 9.65 inches P ACKAGING DIMENSIONS Width: 18.7 inches Height: 31.3 inches Depth: 11.8 inches REPLACEMENT P ARTS Note: use only original replacement parts. This will protec ...

  • DeLonghi WIR2 - page 16

    16 TROUBLESHOOTING W ARNING: if you smell gas • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instrc- tions • If you cannot reach your gas supplier, call the fire ...

  • DeLonghi WIR2 - page 17

    17 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation W ARNING: only a qualified ser vice person should ser v- ice and repair heater CAUTION: never use wire,needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in, there is no ...

  • DeLonghi WIR2 - page 18

    18 OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice is clogged 2. Inlet gas pressure is too low 1. Clean burner orifice (see clean- ing and maintenance, pag 14) or replace the burner 2. Contact local natural gas com- pany Dalayed ignition of burn- er 1. Manifold pressure is too low 2. Burner orif ...

  • DeLonghi WIR2 - page 19

    19 Limited W arranty What Does This W arraty Cover? We warrant each appliance to be free from defects in material and workmanship. Our obligation under this warranty is limited to replacement or repair , free of charge at our factor y or authorized ser vice centers, of any defective part or par ts there of other than parts damaged in transit, which ...

Производитель DeLonghi Категория Electric Heater

Документы, которые мы получаем от производителя устройства DeLonghi WIR2 мы можем разделить на несколько групп. Это в частности:
- технические чертежи DeLonghi
- инструкции обслуживания WIR2
- паспорта изделия DeLonghi
- информационные брошюры
- энергетические этикетки DeLonghi WIR2
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания DeLonghi WIR2.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа DeLonghi WIR2, инструкции обслуживания, короткие инструкции или инструкции пользователя DeLonghi WIR2. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия DeLonghi WIR2.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства DeLonghi WIR2, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании DeLonghi WIR2 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей DeLonghi WIR2.

Полная инструкция обслуживания DeLonghi, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией DeLonghi WIR2 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания DeLonghi WIR2, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся DeLonghi WIR2, которое найдем в данном документе
3. Советы по использованию основных функций устройства DeLonghi WIR2 - которые должны облегчить нам первые шаги во время использования DeLonghi WIR2
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем DeLonghi WIR2
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра DeLonghi WIR2 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся DeLonghi WIR2?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с DeLonghi WIR2, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с DeLonghi WIR2 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)