    © 1998–2003 National Instruments Corp. All rights reserved. LabVIEW™, National Instru ments™, NI™, ni.com™, NI-DAQ ™, and SCXI™ are t rademarks of National Instrument s Corporation. Product and com pany names mentioned herein are trademarks or trade names of their respective companies. For patent s covering National Instruments produ ...

  • National Instruments SCXI-1321 - page 2

    SCXI-1321 T erminal Block Installation Guide 2 ni.com italic Italic text denotes variables, emphasis, a cross reference, or an int roduction to a key concept. This font also denote s te xt that is a placeholder for a word or v alue that you must supply . monospace T ext in this font denotes text or ch aracters that you should enter from the keyboar ...

  • National Instruments SCXI-1321 - page 3

    © National Instruments Cor poration 3 SCXI-1321 T erminal Block Installa tion Guide Connecting the Signals Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers, or connecting or disconnecting any signal wires. To connect the signal to the terminal block, complete the following steps, re ...

  • National Instruments SCXI-1321 - page 4

    SCXI-1321 T erminal Block Installation Guide 4 ni.com Figure 1. SCXI-132 1 Parts Locator Diagram 1 Strain-Relief Bar 2 Strain-Relief Screws 3 Safety-Ground Lug 4 Mating Connector 5 Thumbscrew 6 Top-Cover Screws 7 Top Cover Back Vie w F ront View 2 1 3 4 5 7 6 ...

  • National Instruments SCXI-1321 - page 5

    © National Instruments Cor poration 5 SCXI-1321 T erminal Block Installa tion Guide Figure 2. SCXI-1321 Circuit Parts Locator Diagram Installing the T erminal Block To connect the terminal block to the SCXI mo dule front connector, complete the follow ing steps: 1. Connect the module front connector to its connector on the terminal block. 2. Make ...

  • National Instruments SCXI-1321 - page 6

    SCXI-1321 T erminal Block Installation Guide 6 ni.com Note T o minimize the temperature gradient inside the termin al block, move the SCXI chassis aw ay from any extr eme temperature dif ferential. Specifications All specifications are typical at 25 °C unless otherwise specified . Electrical Cold-junction sensor Accuracy 1 ........... ............ ...

  • National Instruments SCXI-1321 - page 7

    © National Instruments Cor poration 7 SCXI-1321 T erminal Block Installa tion Guide Environmental Operating temperature........................ .... 0 to 50 °C Storage temperature ............. ................. . –20 to 70 °C Humidity ............. .............. .............. ....... 10 to 90% RH, noncondensing Maximum altitude ............ ...

  • National Instruments SCXI-1321 - page 8

    SCXI-1321 T erminal Block Installation Guide 8 ni.com Note Refer to the Declaration of Conformity (DoC) for this product fo r any additional regulatory compliance in formation. T o obtain th e DoC for this p roduct, click Declarations of Conformity Information at ni.com/hardref.nsf/ . Performed or Supported Signal Conditioning This section provides ...

  • National Instruments SCXI-1321 - page 9

    © National Instruments Cor poration 9 SCXI-1321 T erminal Block Installa tion Guide The factory default v alue of all the nulling resistors on the terminal blo ck is 39 k Ω . Note These resistors are socketed for easy re placement. These sockets best f it a 1/4 W resistor lead size. T o determ ine the nulling range, use the f ollowing formula wh ...

  • National Instruments SCXI-1321 - page 10

    SCXI-1321 T erminal Block Installation Guide 10 ni.com Assuming a strain-gauge range with a gauge factor of GF = 2 and a quarter-bridge conf iguration, this range corresponds to ±1,498 µε , as given by the strain formula for a quarter-bridge strain-gauge configuration: where Figure 3. Quarter-Bridge Nulling Circuit ε 4 V r – GF 12 V r + () -- ...

  • National Instruments SCXI-1321 - page 11

    © National Instruments Cor poration 11 SCXI-1321 T erminal Bloc k Installa tion Guide Figure 4. Half-Bridge Nulling Circuit CH+ CH+ CH– EX+ EX– + – + – R 1 R 2 4.5 k Ω 4.5 k Ω R SCAL 301 k Ω R Tr i m 10 k Ω R Null 39.1 k Ω (Screw Adjusts P otentiometer) R L R L R L R 4 (gauge) EX+ CH+ CH+ CH– EX+ EX– R Tr i m SCXI-1121 SCXI-1 ...

  • National Instruments SCXI-1321 - page 12

    SCXI-1321 T erminal Block Installation Guide 12 ni.com Figure 5. Full-Bridge Nulling Cir cuit Shunt Calibration Shunt calibration prov ides a method of adjusti ng for gain error to improve accuracy. The shunt-calibration circui try configuration places a shunting resistor in parallel with the resis tive element connected between EX+ and CH+ (elemen ...

  • National Instruments SCXI-1321 - page 13

    © National Instruments Cor poration 13 SCXI-1321 T erminal Bloc k Installa tion Guide z is the module slot of the SCXI-1121 w is the channel o f the module that you want to engage th e shunt and take measurements For e xample, if you want to measure th e volta ge at channel 0 with the shunt resistor enabled, use the SCXI channel string ob0 ! sc1 ! ...

  • National Instruments SCXI-1321 - page 14

    SCXI-1321 T erminal Block Installation Guide 14 ni.com gauge with a gauge factor of GF = 2, V exc = 3.3 V , and R = 120 Ω prod uces the following: V change = 0.3321 mV Replacing the strained voltage by V change in the quarter-bridge strain equation produces an equ i valent 199 µε of change. Refer to the NI-DAQ User Manual for more informat ion ...

  • National Instruments SCXI-1321 - page 15

    © National Instruments Cor poration 15 SCXI-1321 T erminal Bloc k Installa tion Guide Y ou can read a temperature at the begi nning of the test and use that value with the data that follows. Using this method assumes that there are no temperature v ariations during the measurement period. If there are temperature variations, the measure m ents can ...

  • National Instruments SCXI-1321 - page 16

    321924C-01 J an03 *321924C-01* W3 Nulling circuit of Channel 2 is enabled (factory default setting) Nulling circuit of Channel 2 is disabled W4 Nulling circuit of Channel 3 is enabled (factory default setting) Nulling circuit of Channel 3 is disabled Table 4. Jumper Settings of the Nu lling Circuits (Continued) Jum p e r Pos i t i o n Description D ...

Produzent National Instruments Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts National Instruments SCXI-1321 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen National Instruments
- Bedienungsanleitungen SCXI-1321
- Produktkarten National Instruments
- Informationsbroschüren
- oder Energieetiketten National Instruments SCXI-1321
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung National Instruments SCXI-1321.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen National Instruments SCXI-1321, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen National Instruments SCXI-1321. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts National Instruments SCXI-1321 ansehen.

Die komplette Bedienungsanleitung des Geräts National Instruments SCXI-1321, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von National Instruments SCXI-1321 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von National Instruments SCXI-1321 verständlich ist.

Eine gänzliche Bedienungsanleitung von National Instruments sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von National Instruments SCXI-1321 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von National Instruments SCXI-1321 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich National Instruments SCXI-1321, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts National Instruments SCXI-1321 - die uns die ersten Schritte während der Nutzung von National Instruments SCXI-1321 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit National Instruments SCXI-1321 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von National Instruments SCXI-1321 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich National Instruments SCXI-1321?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit National Instruments SCXI-1321 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit National Instruments SCXI-1321 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)