Bedienungsanleitung Napoleon Fireplaces GDS25N

28 Seiten 3.25 mb
Download

Zur Seite of 28

Summary
  • Napoleon Fireplaces GDS25N - page 1

    1 W415-0547 / C / 07.25.06 W415-0547 / C / 07.25.06 ...

  • Napoleon Fireplaces GDS25N - page 2

    2 W415-0547 / C / 07.25.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. Insta ...

  • Napoleon Fireplaces GDS25N - page 3

    3 W415-0547 / C / 07.25.06 W ARNING • The stove is a vented gas- fi red heater. Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the stove is hot. ? ...

  • Napoleon Fireplaces GDS25N - page 4

    4 W415-0547 / C / 07.25.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Cer tifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-? ...

  • Napoleon Fireplaces GDS25N - page 5

    5 W415-0547 / C / 07.25.06 The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug. FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST- FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 1 1 inches ...

  • Napoleon Fireplaces GDS25N - page 6

    6 W415-0547 / C / 07.25.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . TO CEILING FROM STOVE TOP ..................................................48" HORIZONT AL VENT SIDES AND BOTTOM ........................................................... ...

  • Napoleon Fireplaces GDS25N - page 7

    7 W415-0547 / C / 07.25.06 BL O WER INST ALLA TION 4 5 8 2 3 1 9 7 7 4 Blower ( SEE LOCA TION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower . 3. Connect the black blower wire to the black wire coming from below the un ...

  • Napoleon Fireplaces GDS25N - page 8

    8 W415-0547 / C / 07.25.06 * * * * * Recommended to pr event condensa tion on windows and thermal break age ** ** ** ** * * It is recommended to use a hea t shield and to maximiz e the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 r equires a minim um 18 inc hes clear ance fr om an inside corner . **** **** **** **** ...

  • Napoleon Fireplaces GDS25N - page 9

    9 W415-0547 / C / 07.25.06 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed usin ...

  • Napoleon Fireplaces GDS25N - page 10

    10 W415-0547 / C / 07.25.06 USE GD201 PERISCOPE KIT BELOW GRADE INSTALLATION MAXIMUM 10FT VENT LENGTH OF HORIZONTAL REGARDLESS VENT LENGTH 24" MINIMUM 12"MINIMUM Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a ...

  • Napoleon Fireplaces GDS25N - page 11

    11 W415-0547 / C / 07.25.06 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION 0 2.5 5 7.5 10 12.5 15 40 10 20 30 17.5 20 39 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) for the following symbols used in the venting calculat ...

  • Napoleon Fireplaces GDS25N - page 12

    12 W415-0547 / C / 07.25.06 V 1 HORIZONT AL TERMINA TION 20 10 0 5 10 15 90 100 120 11 0 30 40 50 60 70 80 130 140 150 20 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent con fi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula ...

  • Napoleon Fireplaces GDS25N - page 13

    13 W415-0547 / C / 07.25.06 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Napoleon Fireplaces GDS25N - page 14

    14 W415-0547 / C / 07.25.06 H 1 VERTICAL TERMIN A TION 0 51 0 1 5 2 0 10 20 3 25 30 19 F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: V 1 = 1 ft when (H T ) > (V T ) Simple venting con fi gurations See graph to determine the required vertical rise V T for the required horizontal run H T . For vent con fi gurations re ...

  • Napoleon Fireplaces GDS25N - page 15

    15 W415-0547 / C / 07.25.06 VERTICAL THR OUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-lin- ear aluminum fl ex vent system running the full length of a masonry chimney . The fl exliner accommdates any contours of a masonry chimney , however , it is necessary to keep the fl exible liner as straight as possible. T ...

  • Napoleon Fireplaces GDS25N - page 16

    16 W415-0547 / C / 07.25.06 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN. 1. Assemble the shield to ...

  • Napoleon Fireplaces GDS25N - page 17

    17 W415-0547 / C / 07.25.06 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 2. Stretch the inner aluminum fl ex liner to the required len ...

  • Napoleon Fireplaces GDS25N - page 18

    18 W415-0547 / C / 07.25.06 1. Attach the adjustable pipe to the last section of rigid pip- ing. Secure with screws and seal. 2. Install the 4" aluminium fl exible liner to the stove. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temperature sealant. 3. Run a bead of high tem- perature sealant Mill Pac aro ...

  • Napoleon Fireplaces GDS25N - page 19

    19 W415-0547 / C / 07.25.06 FINISHING GLASS DOOR INST ALLA TION AND REMO V AL CAST FRONT INST ALLA TION AND REMO V AL FRONT SCREWS BRACKET 3 2 Follow the above steps in reverse in order to reinstall the door . Ensure that the bottom of the door meets the door retainer before closing the latches. Follow the above steps in reverse in order to reinsta ...

  • Napoleon Fireplaces GDS25N - page 20

    20 W415-0547 / C / 07.25.06 LOG PLA CEMENT LOGO PLA CEMENT LOGO 1.27cm 1.27cm Remove the backing from the the logo and position onto the control door as shown. It is not necessary to remove the cast front, however , this will make for a more simple log installation. In order to assemble the log set, the glass door must be removed, see Cast Front / ...

  • Napoleon Fireplaces GDS25N - page 21

    21 W415-0547 / C / 07.25.06 OPTIONAL SWIT CH / WIRING DIAGRAM The on/off switch is located on the back of the GDS25 at the top right corner . For ease of acces- sibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH ...

  • Napoleon Fireplaces GDS25N - page 22

    22 W415-0547 / C / 07.25.06 1. STOP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE WALL SWITCH TO OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER T O THE FIREPLACE AND REMOVE BA TTERIES. 4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMA TICALL Y LIGHTS THE PILOT . DO NOT TR Y TO LIGHT THE PILOT BY HAND. 5. TURN MANU ...

  • Napoleon Fireplaces GDS25N - page 23

    23 W415-0547 / C / 07.25.06 NOTE: Check and adjust, if necessary , the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. T urn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open fl ame. 8. Replace the log set. Then light the pilot and main burner to ensure t ...

  • Napoleon Fireplaces GDS25N - page 24

    24 W415-0547 / C / 07.25.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER OF FIREPLACE 2. I NST ALLA TION DA TE OF FIREPLAC ...

  • Napoleon Fireplaces GDS25N - page 25

    25 W415-0547 / C / 07.25.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. ...

  • Napoleon Fireplaces GDS25N - page 26

    26 W415-0547 / C / 07.25.06 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object. T urn the ON/OFF switch to ...

  • Napoleon Fireplaces GDS25N - page 27

    27 W415-0547 / C / 07.25.06 Flames are very ag- gressive. - V enting action is too great. T ighten door clamps Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame. - Blockage in vent. Remove blockage. In really cold conditions, ice buildup may occur on the termin ...

  • Napoleon Fireplaces GDS25N - page 28

    28 W415-0547 / C / 07.25.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Produzent Napoleon Fireplaces Kategorie Electric Heater

Dokumente, die wir vom Produzenten des Geräts Napoleon Fireplaces GDS25N erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Napoleon Fireplaces
- Bedienungsanleitungen GDS25N
- Produktkarten Napoleon Fireplaces
- Informationsbroschüren
- oder Energieetiketten Napoleon Fireplaces GDS25N
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Napoleon Fireplaces GDS25N.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Napoleon Fireplaces GDS25N, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Napoleon Fireplaces GDS25N. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Napoleon Fireplaces GDS25N ansehen.

Die komplette Bedienungsanleitung des Geräts Napoleon Fireplaces GDS25N, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Napoleon Fireplaces GDS25N hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Napoleon Fireplaces GDS25N verständlich ist.

Eine gänzliche Bedienungsanleitung von Napoleon Fireplaces sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Napoleon Fireplaces GDS25N bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Napoleon Fireplaces GDS25N befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Napoleon Fireplaces GDS25N, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Napoleon Fireplaces GDS25N - die uns die ersten Schritte während der Nutzung von Napoleon Fireplaces GDS25N erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Napoleon Fireplaces GDS25N hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Napoleon Fireplaces GDS25N im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Napoleon Fireplaces GDS25N?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Napoleon Fireplaces GDS25N nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Napoleon Fireplaces GDS25N hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)