Manuel d’utilisation Napoleon Fireplaces GDS25N

28 pages 3.25 mb
Télécharger

Aller à la page of 28

Summary
  • Napoleon Fireplaces GDS25N - page 1

    1 W415-0547 / C / 07.25.06 W415-0547 / C / 07.25.06 ...

  • Napoleon Fireplaces GDS25N - page 2

    2 W415-0547 / C / 07.25.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. Insta ...

  • Napoleon Fireplaces GDS25N - page 3

    3 W415-0547 / C / 07.25.06 W ARNING • The stove is a vented gas- fi red heater. Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the stove is hot. ? ...

  • Napoleon Fireplaces GDS25N - page 4

    4 W415-0547 / C / 07.25.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Cer tifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-? ...

  • Napoleon Fireplaces GDS25N - page 5

    5 W415-0547 / C / 07.25.06 The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug. FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST- FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 1 1 inches ...

  • Napoleon Fireplaces GDS25N - page 6

    6 W415-0547 / C / 07.25.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . TO CEILING FROM STOVE TOP ..................................................48" HORIZONT AL VENT SIDES AND BOTTOM ........................................................... ...

  • Napoleon Fireplaces GDS25N - page 7

    7 W415-0547 / C / 07.25.06 BL O WER INST ALLA TION 4 5 8 2 3 1 9 7 7 4 Blower ( SEE LOCA TION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower . 3. Connect the black blower wire to the black wire coming from below the un ...

  • Napoleon Fireplaces GDS25N - page 8

    8 W415-0547 / C / 07.25.06 * * * * * Recommended to pr event condensa tion on windows and thermal break age ** ** ** ** * * It is recommended to use a hea t shield and to maximiz e the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 r equires a minim um 18 inc hes clear ance fr om an inside corner . **** **** **** **** ...

  • Napoleon Fireplaces GDS25N - page 9

    9 W415-0547 / C / 07.25.06 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed usin ...

  • Napoleon Fireplaces GDS25N - page 10

    10 W415-0547 / C / 07.25.06 USE GD201 PERISCOPE KIT BELOW GRADE INSTALLATION MAXIMUM 10FT VENT LENGTH OF HORIZONTAL REGARDLESS VENT LENGTH 24" MINIMUM 12"MINIMUM Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a ...

  • Napoleon Fireplaces GDS25N - page 11

    11 W415-0547 / C / 07.25.06 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION 0 2.5 5 7.5 10 12.5 15 40 10 20 30 17.5 20 39 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) for the following symbols used in the venting calculat ...

  • Napoleon Fireplaces GDS25N - page 12

    12 W415-0547 / C / 07.25.06 V 1 HORIZONT AL TERMINA TION 20 10 0 5 10 15 90 100 120 11 0 30 40 50 60 70 80 130 140 150 20 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent con fi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula ...

  • Napoleon Fireplaces GDS25N - page 13

    13 W415-0547 / C / 07.25.06 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Napoleon Fireplaces GDS25N - page 14

    14 W415-0547 / C / 07.25.06 H 1 VERTICAL TERMIN A TION 0 51 0 1 5 2 0 10 20 3 25 30 19 F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: V 1 = 1 ft when (H T ) > (V T ) Simple venting con fi gurations See graph to determine the required vertical rise V T for the required horizontal run H T . For vent con fi gurations re ...

  • Napoleon Fireplaces GDS25N - page 15

    15 W415-0547 / C / 07.25.06 VERTICAL THR OUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-lin- ear aluminum fl ex vent system running the full length of a masonry chimney . The fl exliner accommdates any contours of a masonry chimney , however , it is necessary to keep the fl exible liner as straight as possible. T ...

  • Napoleon Fireplaces GDS25N - page 16

    16 W415-0547 / C / 07.25.06 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN. 1. Assemble the shield to ...

  • Napoleon Fireplaces GDS25N - page 17

    17 W415-0547 / C / 07.25.06 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 2. Stretch the inner aluminum fl ex liner to the required len ...

  • Napoleon Fireplaces GDS25N - page 18

    18 W415-0547 / C / 07.25.06 1. Attach the adjustable pipe to the last section of rigid pip- ing. Secure with screws and seal. 2. Install the 4" aluminium fl exible liner to the stove. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temperature sealant. 3. Run a bead of high tem- perature sealant Mill Pac aro ...

  • Napoleon Fireplaces GDS25N - page 19

    19 W415-0547 / C / 07.25.06 FINISHING GLASS DOOR INST ALLA TION AND REMO V AL CAST FRONT INST ALLA TION AND REMO V AL FRONT SCREWS BRACKET 3 2 Follow the above steps in reverse in order to reinstall the door . Ensure that the bottom of the door meets the door retainer before closing the latches. Follow the above steps in reverse in order to reinsta ...

  • Napoleon Fireplaces GDS25N - page 20

    20 W415-0547 / C / 07.25.06 LOG PLA CEMENT LOGO PLA CEMENT LOGO 1.27cm 1.27cm Remove the backing from the the logo and position onto the control door as shown. It is not necessary to remove the cast front, however , this will make for a more simple log installation. In order to assemble the log set, the glass door must be removed, see Cast Front / ...

  • Napoleon Fireplaces GDS25N - page 21

    21 W415-0547 / C / 07.25.06 OPTIONAL SWIT CH / WIRING DIAGRAM The on/off switch is located on the back of the GDS25 at the top right corner . For ease of acces- sibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH ...

  • Napoleon Fireplaces GDS25N - page 22

    22 W415-0547 / C / 07.25.06 1. STOP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE WALL SWITCH TO OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER T O THE FIREPLACE AND REMOVE BA TTERIES. 4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMA TICALL Y LIGHTS THE PILOT . DO NOT TR Y TO LIGHT THE PILOT BY HAND. 5. TURN MANU ...

  • Napoleon Fireplaces GDS25N - page 23

    23 W415-0547 / C / 07.25.06 NOTE: Check and adjust, if necessary , the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. T urn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open fl ame. 8. Replace the log set. Then light the pilot and main burner to ensure t ...

  • Napoleon Fireplaces GDS25N - page 24

    24 W415-0547 / C / 07.25.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER OF FIREPLACE 2. I NST ALLA TION DA TE OF FIREPLAC ...

  • Napoleon Fireplaces GDS25N - page 25

    25 W415-0547 / C / 07.25.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd. ...

  • Napoleon Fireplaces GDS25N - page 26

    26 W415-0547 / C / 07.25.06 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object. T urn the ON/OFF switch to ...

  • Napoleon Fireplaces GDS25N - page 27

    27 W415-0547 / C / 07.25.06 Flames are very ag- gressive. - V enting action is too great. T ighten door clamps Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame. - Blockage in vent. Remove blockage. In really cold conditions, ice buildup may occur on the termin ...

  • Napoleon Fireplaces GDS25N - page 28

    28 W415-0547 / C / 07.25.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Fabricant Napoleon Fireplaces Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilNapoleon Fireplaces GDS25N peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Napoleon Fireplaces
- manuels d’utilisations GDS25N
- fiches produit Napoleon Fireplaces
- dépliants
- ou étiquettes-énergie Napoleon Fireplaces GDS25N
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Napoleon Fireplaces GDS25N.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Napoleon Fireplaces GDS25N, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Napoleon Fireplaces GDS25N. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Napoleon Fireplaces GDS25N.

Manuel d’utilisation complet de l’appareil Napoleon Fireplaces GDS25N, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Napoleon Fireplaces GDS25N par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Napoleon Fireplaces GDS25N.

Le manuel d’utilisation complet Napoleon Fireplaces, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Napoleon Fireplaces GDS25N - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Napoleon Fireplaces GDS25N, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNapoleon Fireplaces GDS25N qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Napoleon Fireplaces GDS25N - qui devraient nous aider dans les premières étapes lors de l'utilisation Napoleon Fireplaces GDS25N
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Napoleon Fireplaces GDS25N
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Napoleon Fireplaces GDS25N dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Napoleon Fireplaces GDS25N?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Napoleon Fireplaces GDS25N, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Napoleon Fireplaces GDS25N il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)