Bedienungsanleitung Emerson ADTS

13 Seiten 0.79 mb
Download

Zur Seite of 13

Summary
  • Emerson ADTS - page 1

    381333–272 B 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 telephone 519 758– 8450, f ax 519 758– 0876, f or service ca ll 1 888 234–2726 (A SCO ) ...

  • Emerson ADTS - page 2

    Ca talog Num ber Identif ication T ypi cal 4000 Series cata log no. for J–design, 2 pole, 260 amp, 240 V , ADTS i n T ype 1 enclosure: 4ADT S A 2 260 F 5 C Phase Poles Neutral A –s o l i d Amperes Vo l t a g e Co ntro ller Enc los ure B –s w i t c h e d 5X –i f accessor ies order ed 5 –s t a n d a r d G –t y p e4 C –t y p e1 F –t y ...

  • Emerson ADTS - page 3

    SECT ION 1 INST ALLA TION 1 --- 1 A SCO 4000 Seri es A utomati c De layed–T ransiti on T ra ns- fer Switc hes are factor y wired and tested. Field ins talla- tion si mply requires mounti ng and c onnectio n of service cables, and auxi liary control circuits (i f re quire d). Remove th e Shipping S kid F or larg e switches, open t he front door an ...

  • Emerson ADTS - page 4

    INST ALLA TION (cont inued) 1 --- 2 Contr oller Ground A g rounding wire mus t be con nected to the c ontroll er’s lower left mounti ng stud. Because the controll er i s mounted on the encl osure door, a conduc ti ve st rap must be used between the e nclosure and t he door. This connection provides prope r grounding which does not rely upon the d ...

  • Emerson ADTS - page 5

    INST ALLA TION (cont inued) 1 --- 3 F unctio nal T est The F unctional T est consists of th ree chec ks: ❐ 1 — Manua l Opera tion T est , pa ges 1–3 t hrough 1–6 ❐ 2—V o l t a g e C h e c k s , p a g e 1 – 7 ❐ 3 — Elect ri ca l Ope ra ti o n, p age 1 –8 Do thes e checks in the ord er pre sented to avoi d damagi ng th e A TS. R e ...

  • Emerson ADTS - page 6

    INST ALLA TION (cont inued) 1 --- 4 maintenance handle left s id e of transfer switch clip Emergency source contact shaft hub Norma l sou rce contact shaft hub J–d e sig n 150– 600 amp Figure 1- 6. Maintenance h andle on 150–600 amp. J–design transf er switches. Hubs shown with Normal contacts closed & Emergency open. handle hub UP ope ...

  • Emerson ADTS - page 7

    INST ALLA TION (cont inued) 1 --- 5 Do no t manua ll y op erate the transfer switch until both po wer so urces are disconnected: open b oth circuit breakers. T able C. Maintenance handle positio ns on 150–1200 amp. t ransfer switches. . Tr a n s f e r S w i t c h Po s it i o n J–design 150 - - - 600 A Interlocked Shafts 1 Link between contact s ...

  • Emerson ADTS - page 8

    INST ALLA TION (cont inued) 1 --- 6 clockwise DOWN OP ENS the contacts Pull ou t shaft to close Emergency source contacts (upper) Pus h in shaft to close No rmal source contacts (lo wer) counterclo ckw ise DOWN OP ENS the contacts Pull ou t shaft t o open Emergency source contacts (upper) Pus h in shaft to open Normal source contacts (lo wer) windo ...

  • Emerson ADTS - page 9

    INST ALLA TION (cont inued) 1 --- 7 obse rve these li ghts Pres s for 15 Sec. Figure 1- 14. Standard control s and indicators. 2 --- V o l t a g e C h e c k s First c heck the n amepl ate on the tr ansfer sw itch; the rated vol tage m ust be the s ame as the no rmal and emerg ency l ine voltag es. V erify that t he feeders have been connected to th ...

  • Emerson ADTS - page 10

    INST ALLA TION (cont inued) 1 --- 8 obse rve these li ghts press these buttons step 2 step 4 If this l ight is o n, the buttons will not work until the c ontrols are unl ocked. If this l ight is bli nking, the user control s are unlocked fo r 5 minutes. Pres s for 15 Sec. Figure 1- 15. User controls and i ndicators. 3 - - - Elect rical O pera tion ...

  • Emerson ADTS - page 11

    SECT ION 2 TEST ING & SERVIC E 2 --- 1 TRA NS FE R TEST Operate t he 4000 Series ADTS at least o nce a month by foll owing the five–step El ectric al Operation T ransfer Te s t procedure on page 1–7. PREVENTIV E MAINTENANCE R easonab le care in prev entive m aintenan ce will insur e high reliabilit y and long l if e for the 4000 Seri es ADT ...

  • Emerson ADTS - page 12

    TEST ING & SERVIC E (continued) 2 --- 2 MAN UAL L O AD TRANSFE R This pr oced ure wil l m anual ly tran sfer the l oad if the cont ro lle r is d i sco nne ct ed . Do no t manua ll y op erate the transfer switch until both po wer so urces are disconnected (al l co nductors deenergized). 1. Deenerg ize both the n ormal and emer genc y source cond ...

  • Emerson ADTS - page 13

    INDEX Printed in U .S.A . ASCO Power T echnologies, L.P . 2007 A auxil iary cir cuits , 1–2 C cable lugs, 1–2 prepar ation, 1–2 cat alo g nu mber, in si de co ve r cleaning, 2–1 connections line, 1–1 co ntact pos ition indic ators, 1– 3 controller, 1–1 disconnecting, 2–1 see Controller Us er’s Gu ide E elec trical operation , 1– ...

Produzent Emerson Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Emerson ADTS erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen ADTS
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson ADTS
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson ADTS.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson ADTS, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson ADTS. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson ADTS ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson ADTS, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson ADTS hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson ADTS verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson ADTS bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson ADTS befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson ADTS, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson ADTS - die uns die ersten Schritte während der Nutzung von Emerson ADTS erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson ADTS hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson ADTS im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson ADTS?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson ADTS nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson ADTS hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)