    381333–272 B 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 telephone 519 758– 8450, f ax 519 758– 0876, f or service ca ll 1 888 234–2726 (A SCO ) ...

  • Emerson ADTS - page 2

    Ca talog Num ber Identif ication T ypi cal 4000 Series cata log no. for J–design, 2 pole, 260 amp, 240 V , ADTS i n T ype 1 enclosure: 4ADT S A 2 260 F 5 C Phase Poles Neutral A –s o l i d Amperes Vo l t a g e Co ntro ller Enc los ure B –s w i t c h e d 5X –i f accessor ies order ed 5 –s t a n d a r d G –t y p e4 C –t y p e1 F –t y ...

  • Emerson ADTS - page 3

    SECT ION 1 INST ALLA TION 1 --- 1 A SCO 4000 Seri es A utomati c De layed–T ransiti on T ra ns- fer Switc hes are factor y wired and tested. Field ins talla- tion si mply requires mounti ng and c onnectio n of service cables, and auxi liary control circuits (i f re quire d). Remove th e Shipping S kid F or larg e switches, open t he front door an ...

  • Emerson ADTS - page 4

    INST ALLA TION (cont inued) 1 --- 2 Contr oller Ground A g rounding wire mus t be con nected to the c ontroll er’s lower left mounti ng stud. Because the controll er i s mounted on the encl osure door, a conduc ti ve st rap must be used between the e nclosure and t he door. This connection provides prope r grounding which does not rely upon the d ...

  • Emerson ADTS - page 5

    INST ALLA TION (cont inued) 1 --- 3 F unctio nal T est The F unctional T est consists of th ree chec ks: ❐ 1 — Manua l Opera tion T est , pa ges 1–3 t hrough 1–6 ❐ 2—V o l t a g e C h e c k s , p a g e 1 – 7 ❐ 3 — Elect ri ca l Ope ra ti o n, p age 1 –8 Do thes e checks in the ord er pre sented to avoi d damagi ng th e A TS. R e ...

  • Emerson ADTS - page 6

    INST ALLA TION (cont inued) 1 --- 4 maintenance handle left s id e of transfer switch clip Emergency source contact shaft hub Norma l sou rce contact shaft hub J–d e sig n 150– 600 amp Figure 1- 6. Maintenance h andle on 150–600 amp. J–design transf er switches. Hubs shown with Normal contacts closed & Emergency open. handle hub UP ope ...

  • Emerson ADTS - page 7

    INST ALLA TION (cont inued) 1 --- 5 Do no t manua ll y op erate the transfer switch until both po wer so urces are disconnected: open b oth circuit breakers. T able C. Maintenance handle positio ns on 150–1200 amp. t ransfer switches. . Tr a n s f e r S w i t c h Po s it i o n J–design 150 - - - 600 A Interlocked Shafts 1 Link between contact s ...

  • Emerson ADTS - page 8

    INST ALLA TION (cont inued) 1 --- 6 clockwise DOWN OP ENS the contacts Pull ou t shaft to close Emergency source contacts (upper) Pus h in shaft to close No rmal source contacts (lo wer) counterclo ckw ise DOWN OP ENS the contacts Pull ou t shaft t o open Emergency source contacts (upper) Pus h in shaft to open Normal source contacts (lo wer) windo ...

  • Emerson ADTS - page 9

    INST ALLA TION (cont inued) 1 --- 7 obse rve these li ghts Pres s for 15 Sec. Figure 1- 14. Standard control s and indicators. 2 --- V o l t a g e C h e c k s First c heck the n amepl ate on the tr ansfer sw itch; the rated vol tage m ust be the s ame as the no rmal and emerg ency l ine voltag es. V erify that t he feeders have been connected to th ...

  • Emerson ADTS - page 10

    INST ALLA TION (cont inued) 1 --- 8 obse rve these li ghts press these buttons step 2 step 4 If this l ight is o n, the buttons will not work until the c ontrols are unl ocked. If this l ight is bli nking, the user control s are unlocked fo r 5 minutes. Pres s for 15 Sec. Figure 1- 15. User controls and i ndicators. 3 - - - Elect rical O pera tion ...

  • Emerson ADTS - page 11

    SECT ION 2 TEST ING & SERVIC E 2 --- 1 TRA NS FE R TEST Operate t he 4000 Series ADTS at least o nce a month by foll owing the five–step El ectric al Operation T ransfer Te s t procedure on page 1–7. PREVENTIV E MAINTENANCE R easonab le care in prev entive m aintenan ce will insur e high reliabilit y and long l if e for the 4000 Seri es ADT ...

  • Emerson ADTS - page 12

    TEST ING & SERVIC E (continued) 2 --- 2 MAN UAL L O AD TRANSFE R This pr oced ure wil l m anual ly tran sfer the l oad if the cont ro lle r is d i sco nne ct ed . Do no t manua ll y op erate the transfer switch until both po wer so urces are disconnected (al l co nductors deenergized). 1. Deenerg ize both the n ormal and emer genc y source cond ...

  • Emerson ADTS - page 13

    INDEX Printed in U .S.A . ASCO Power T echnologies, L.P . 2007 A auxil iary cir cuits , 1–2 C cable lugs, 1–2 prepar ation, 1–2 cat alo g nu mber, in si de co ve r cleaning, 2–1 connections line, 1–1 co ntact pos ition indic ators, 1– 3 controller, 1–1 disconnecting, 2–1 see Controller Us er’s Gu ide E elec trical operation , 1– ...

Fabricante Emerson Categoría Switch

Los documentos del dispositivo Emerson ADTS que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones ADTS
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson ADTS
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson ADTS.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson ADTS, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson ADTS. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson ADTS.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson ADTS, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson ADTS. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson ADTS.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson ADTS - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson ADTS, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson ADTS que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson ADTS - que deben facilitarnos los primeros pasos durante el uso de Emerson ADTS
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson ADTS
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson ADTS en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson ADTS?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson ADTS, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson ADTS probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)