OPERATING INSTRUCTIONS AND S PECIFICATIONS NI 9426 32-Channel, 24 V, Sourcing Digital Input Module ni.com/manuals Deutsch Français ...
-
National Instruments NI 9426 - page 2
NI 9426 Operating I nstruction s and Specificati ons 2 ni.com This doc u ment describes ho w to u se the National Instr u ments 9426 and incl u des specif ications and pin assignments for the NI 9426. Vi s i t ni.com/info and enter rd s oftwarever s ion to determine which software yo u need for the mod u les yo u are u sing. For information abo u t ...
-
National Instruments NI 9426 - page 3
© National Inst ruments Corp. 3 NI 9426 Operating Instructi ons and Specific ations Safety Guidelines for Hazardous V oltages If hazardo u s voltages are connected to the mod u le, ta ke the follow ing preca u tions. A hazardo u s v oltage is a voltage greater than 42.4 V pk or 60 VDC to earth gro u nd. Caution Ens u re that hazardo u s voltage wi ...
-
National Instruments NI 9426 - page 4
NI 9426 Operating I nstruction s and Specificati ons 4 ni.com Ex nA IIC T4 hazardo u s locations; and nonhazardo u s locations only . Follow these g u ideli nes if yo u are i nstalling the NI 942 6 in a potentially explosi ve en vironm ent. Not following the se g u idelines may res u lt in serio u s inj u ry or death. Caution Do not disconnect I/O- ...
-
National Instruments NI 9426 - page 5
© National Inst ruments Corp. 5 NI 9426 Operating Instructi ons and Specific ations Special Conditions for Hazard ous Locations Use in Europe This eq u ipment has been e v al u ated as Ex nA IIC T4 eq u ipment u nder DEMK O Certificate No. 07 A TEX 0626664X. Each mod u le is marked II 3G and is s u itable for u se in Zone 2 hazardo u s locations. ...
-
National Instruments NI 9426 - page 6
NI 9426 Operating I nstruction s and Specificati ons 6 ni.com Connecting the NI 9426 The NI 9426 has a 37-pin DSUB connector that pro vides connections for 32 sim u ltaneo u sly-sampled digital inp u t channels. Figure 1. NI 9426 Pin Assignm ents DI16 DI17 DI18 DI19 DI20 DI21 DI22 DI23 Vsup Vsup DI24 DI25 DI26 DI27 DI28 DI29 DI30 DI31 DI0 DI1 DI2 D ...
-
National Instruments NI 9426 - page 7
© National Inst ruments Corp. 7 NI 9426 Operating Instructi ons and Specific ations Each channel has a DI pin to which yo u can connect a digital inp u t signal. The NI 9426 has fo u r s u pply pins, V s u p , that are interna lly connected to the isolated reference of the mod u le. The NI 9426 has so u rcing inp u ts, meaning the DI pin so u rces ...
-
National Instruments NI 9426 - page 8
NI 9426 Operating I nstruction s and Specificati ons 8 ni.com Figure 2. Connecting a Device to the NI 9426 (Three-Wire Device Shown) The NI 9426 channel re gisters as ON when the sinking-o u tp u t de vice driv es the inp u t below V s u p and meets the inp u t ON range. The channel re gisters as OFF when the de vice does not dri ve the inp u t low ...
-
National Instruments NI 9426 - page 9
© National Inst ruments Corp. 9 NI 9426 Operat ing Instructi ons and Specif ications Sleep Mode This mod u le s u pports a low-po wer sleep mode. S u pport for sleep mode at the system le vel depe nds on the chassis that the mod u le is pl u gged into. Refer to the chassis man u al for information abo u t s u pport for sleep mode. If the chassis s ...
-
National Instruments NI 9426 - page 10
NI 9426 Operating I nstruction s and Specificati ons 10 ni.com Inp u t type ........ ........... ........... ........... . So u rcing Digital logic le v els OFF state Inp u t v oltage 1 ............. ......... . ≥ ( V sup – 5 V) Inp u t c u rrent ...... ........... ........ ≤ 150 μ A from DI pin ON state Inp u t v oltage 1 ............. .... ...
-
National Instruments NI 9426 - page 11
© National Inst ruments Corp. 11 NI 9426 Operating Instructi ons and Specific ations Hold time 1 ......... ......... ........... ........... . 0 s mi n Set u p time 2 .......... ........... ......... .......... 1 μ s min Update/transfer time 3 .......... ......... ..... 7 μ s max MTBF .......... ........... ............ ........... ... 955,723 h ...
-
National Instruments NI 9426 - page 12
NI 9426 Operating I nstruction s and Specificati ons 12 ni.com Power Requirements Power cons u mption fr om chassis Active mode .............. ............ ..... 615 mW max Sleep mode 1 ...... ......... ............ ..... 5 mW max Thermal dissipation (at 70 °C) Active mode ............ ........... ........ 1.35 W max Sleep mode .......... ........ ...
-
National Instruments NI 9426 - page 13
© National Inst ruments Corp. 13 NI 9426 Operating Instructi ons and Specific ations Isolation Channel-to-channel ............... ..... None Channel-to-earth gro u nd Contin u o u s ........ ........... ........ 60 VDC, Meas u rement Category I W ithstand .......... ........... ........ 1,000 V rms , ver i fie d by a 5 s dielectric withstand test ...
-
National Instruments NI 9426 - page 14
NI 9426 Operating I nstruction s and Specificati ons 14 ni.com Safety Standards This prod u ct is designed to meet the req u ire ments of the follo wing standards of safety for electrical eq u ipment for meas u rement, control, and laboratory u se: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ications, ...
-
National Instruments NI 9426 - page 15
© National Inst ruments Corp. 15 NI 9426 Operating Instructi ons and Specific ations Environmental National Instr u ments C Series mod u les are intend ed for indoor u se only b u t may be u sed o u tdoors if installed in a s u itabl e enclos u re. Refer to th e man u al for the chassis yo u are u sing for more information abo u t meeting th ese s ...
-
National Instruments NI 9426 - page 16
NI 9426 Operating I nstruction s and Specificati ons 16 ni.com Shock and Vibration T o meet thes e specifications, yo u m u st panel mo u nt the system. Operating vibration Random (IEC 60068-2-64)......... 5 g rms , 10 to 500 Hz Sin u soidal (IEC 60068-2-6) ....... 5 g, 10 to 500 Hz Operating shock (IEC 60068-2-27)........... ........... ........ 3 ...
-
National Instruments NI 9426 - page 17
© National Inst ruments Corp. 17 NI 9426 Operating Instructi ons and Specific ations CE Compliance This prod u ct meets the essent ial req u irem ents of app licable E u ropean directi ves, as amended for CE markings, as follo ws: • 2006/95/EC; Low-V oltage Directi ve (safety) • 2004/108/EC; Electromagneti c Compatibility Directive (EMC) Note ...
-
National Instruments NI 9426 - page 18
NI 9426 Operating I nstruction s and Specificati ons 18 ni.com For additional en viro nmental information, refer to the NI a nd the Environment W eb page at ni.com/environment . This page contains the en vironmental reg u lations and direct i ves with which NI complies, as well as othe r en vironmental information not incl u ded in this doc u ment. ...
-
National Instruments NI 9426 - page 19
© National Inst ruments Corp. 19 NI 9426 Operating Instructions and Specific ations Where to Go for Support The National Instr u ments W eb site is yo u r complete reso u rce for technical s u pport. At ni.com/ s upport yo u have access to ev erything from tro u bleshooting and applic ation de velopment self-help reso u rces to email and phone ass ...
-
National Instruments NI 9426 - page 20
© 2007–2008 Nati onal Instruments Corp. All rights reserved. 374712D-01 May08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more information about Natio nal Instruments trademarks. Other product and company names ment ioned herein are trad ...
Haben Sie eine Frage bezüglich National Instruments NI 9426?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit National Instruments NI 9426 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit National Instruments NI 9426 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.