    OPERATING INSTRUCTIONS AND S PECIFICATIONS NI 9426 32-Channel, 24 V, Sourcing Digital Input Module ni.com/manuals Deutsch Français ...

  • National Instruments NI 9426 - page 2

    NI 9426 Operating I nstruction s and Specificati ons 2 ni.com This doc u ment describes ho w to u se the National Instr u ments 9426 and incl u des specif ications and pin assignments for the NI 9426. Vi s i t ni.com/info and enter rd s oftwarever s ion to determine which software yo u need for the mod u les yo u are u sing. For information abo u t ...

  • National Instruments NI 9426 - page 3

    © National Inst ruments Corp. 3 NI 9426 Operating Instructi ons and Specific ations Safety Guidelines for Hazardous V oltages If hazardo u s voltages are connected to the mod u le, ta ke the follow ing preca u tions. A hazardo u s v oltage is a voltage greater than 42.4 V pk or 60 VDC to earth gro u nd. Caution Ens u re that hazardo u s voltage wi ...

  • National Instruments NI 9426 - page 4

    NI 9426 Operating I nstruction s and Specificati ons 4 ni.com Ex nA IIC T4 hazardo u s locations; and nonhazardo u s locations only . Follow these g u ideli nes if yo u are i nstalling the NI 942 6 in a potentially explosi ve en vironm ent. Not following the se g u idelines may res u lt in serio u s inj u ry or death. Caution Do not disconnect I/O- ...

  • National Instruments NI 9426 - page 5

    © National Inst ruments Corp. 5 NI 9426 Operating Instructi ons and Specific ations Special Conditions for Hazard ous Locations Use in Europe This eq u ipment has been e v al u ated as Ex nA IIC T4 eq u ipment u nder DEMK O Certificate No. 07 A TEX 0626664X. Each mod u le is marked II 3G and is s u itable for u se in Zone 2 hazardo u s locations. ...

  • National Instruments NI 9426 - page 6

    NI 9426 Operating I nstruction s and Specificati ons 6 ni.com Connecting the NI 9426 The NI 9426 has a 37-pin DSUB connector that pro vides connections for 32 sim u ltaneo u sly-sampled digital inp u t channels. Figure 1. NI 9426 Pin Assignm ents DI16 DI17 DI18 DI19 DI20 DI21 DI22 DI23 Vsup Vsup DI24 DI25 DI26 DI27 DI28 DI29 DI30 DI31 DI0 DI1 DI2 D ...

  • National Instruments NI 9426 - page 7

    © National Inst ruments Corp. 7 NI 9426 Operating Instructi ons and Specific ations Each channel has a DI pin to which yo u can connect a digital inp u t signal. The NI 9426 has fo u r s u pply pins, V s u p , that are interna lly connected to the isolated reference of the mod u le. The NI 9426 has so u rcing inp u ts, meaning the DI pin so u rces ...

  • National Instruments NI 9426 - page 8

    NI 9426 Operating I nstruction s and Specificati ons 8 ni.com Figure 2. Connecting a Device to the NI 9426 (Three-Wire Device Shown) The NI 9426 channel re gisters as ON when the sinking-o u tp u t de vice driv es the inp u t below V s u p and meets the inp u t ON range. The channel re gisters as OFF when the de vice does not dri ve the inp u t low ...

  • National Instruments NI 9426 - page 9

    © National Inst ruments Corp. 9 NI 9426 Operat ing Instructi ons and Specif ications Sleep Mode This mod u le s u pports a low-po wer sleep mode. S u pport for sleep mode at the system le vel depe nds on the chassis that the mod u le is pl u gged into. Refer to the chassis man u al for information abo u t s u pport for sleep mode. If the chassis s ...

  • National Instruments NI 9426 - page 10

    NI 9426 Operating I nstruction s and Specificati ons 10 ni.com Inp u t type ........ ........... ........... ........... . So u rcing Digital logic le v els OFF state Inp u t v oltage 1 ............. ......... . ≥ ( V sup – 5 V) Inp u t c u rrent ...... ........... ........ ≤ 150 μ A from DI pin ON state Inp u t v oltage 1 ............. .... ...

  • National Instruments NI 9426 - page 11

    © National Inst ruments Corp. 11 NI 9426 Operating Instructi ons and Specific ations Hold time 1 ......... ......... ........... ........... . 0 s mi n Set u p time 2 .......... ........... ......... .......... 1 μ s min Update/transfer time 3 .......... ......... ..... 7 μ s max MTBF .......... ........... ............ ........... ... 955,723 h ...

  • National Instruments NI 9426 - page 12

    NI 9426 Operating I nstruction s and Specificati ons 12 ni.com Power Requirements Power cons u mption fr om chassis Active mode .............. ............ ..... 615 mW max Sleep mode 1 ...... ......... ............ ..... 5 mW max Thermal dissipation (at 70 °C) Active mode ............ ........... ........ 1.35 W max Sleep mode .......... ........ ...

  • National Instruments NI 9426 - page 13

    © National Inst ruments Corp. 13 NI 9426 Operating Instructi ons and Specific ations Isolation Channel-to-channel ............... ..... None Channel-to-earth gro u nd Contin u o u s ........ ........... ........ 60 VDC, Meas u rement Category I W ithstand .......... ........... ........ 1,000 V rms , ver i fie d by a 5 s dielectric withstand test ...

  • National Instruments NI 9426 - page 14

    NI 9426 Operating I nstruction s and Specificati ons 14 ni.com Safety Standards This prod u ct is designed to meet the req u ire ments of the follo wing standards of safety for electrical eq u ipment for meas u rement, control, and laboratory u se: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ications, ...

  • National Instruments NI 9426 - page 15

    © National Inst ruments Corp. 15 NI 9426 Operating Instructi ons and Specific ations Environmental National Instr u ments C Series mod u les are intend ed for indoor u se only b u t may be u sed o u tdoors if installed in a s u itabl e enclos u re. Refer to th e man u al for the chassis yo u are u sing for more information abo u t meeting th ese s ...

  • National Instruments NI 9426 - page 16

    NI 9426 Operating I nstruction s and Specificati ons 16 ni.com Shock and Vibration T o meet thes e specifications, yo u m u st panel mo u nt the system. Operating vibration Random (IEC 60068-2-64)......... 5 g rms , 10 to 500 Hz Sin u soidal (IEC 60068-2-6) ....... 5 g, 10 to 500 Hz Operating shock (IEC 60068-2-27)........... ........... ........ 3 ...

  • National Instruments NI 9426 - page 17

    © National Inst ruments Corp. 17 NI 9426 Operating Instructi ons and Specific ations CE Compliance This prod u ct meets the essent ial req u irem ents of app licable E u ropean directi ves, as amended for CE markings, as follo ws: • 2006/95/EC; Low-V oltage Directi ve (safety) • 2004/108/EC; Electromagneti c Compatibility Directive (EMC) Note ...

  • National Instruments NI 9426 - page 18

    NI 9426 Operating I nstruction s and Specificati ons 18 ni.com For additional en viro nmental information, refer to the NI a nd the Environment W eb page at ni.com/environment . This page contains the en vironmental reg u lations and direct i ves with which NI complies, as well as othe r en vironmental information not incl u ded in this doc u ment. ...

  • National Instruments NI 9426 - page 19

    © National Inst ruments Corp. 19 NI 9426 Operating Instructions and Specific ations Where to Go for Support The National Instr u ments W eb site is yo u r complete reso u rce for technical s u pport. At ni.com/ s upport yo u have access to ev erything from tro u bleshooting and applic ation de velopment self-help reso u rces to email and phone ass ...

  • National Instruments NI 9426 - page 20

    © 2007–2008 Nati onal Instruments Corp. All rights reserved. 374712D-01 May08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more information about Natio nal Instruments trademarks. Other product and company names ment ioned herein are trad ...

Fabbricante National Instruments Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments NI 9426 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso NI 9426
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments NI 9426
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments NI 9426.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments NI 9426, manuali di manutenzione, brevi manuali o manuali utente National Instruments NI 9426. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments NI 9426.

Manuale completo del dispositivo National Instruments NI 9426, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments NI 9426 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments NI 9426.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments NI 9426 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments NI 9426, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments NI 9426 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments NI 9426 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments NI 9426
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments NI 9426
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments NI 9426 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments NI 9426?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments NI 9426 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments NI 9426 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)