    INST ALLA TION & USER INSTR UCTIONS All instructions must be handed to the user for saf ek eeping. Revision A - 08/07 Countr y(s) of destination - GB/IE L30 F AB P23 LINEAR, P23 CLASSIC L23 LINEAR, L23 CLASSIC MODELS W ALL MOUNTED HIGH EFFICIENCY GAS FIRE SMEG (UK) L TD 3 Milton Park Abingdon, Oxon O X14 4RN Phone: +44 (0)870 99 09 907 Fax : +4 ...

  • Smeg L23LINP - page 2

    L30 Fab P23 Linear P23 Classic L23 Linear L23 Classic © 2007 Smeg (UK) L TD Please note : Except where otherwise stated, all rights, including cop yright in the text, images and la y out of this booklet is owned by Smeg (UK) L TD . Y ou are not permit- ted to cop y or adapt an y of the content without the prior written permission of Smeg (UK) L TD ...

  • Smeg L23LINP - page 3

    This appliance is a high efficiency , flueless catalytic flame effect gas fir e. It pro vides radiant and conv ected warmth both effi cient- ly and safel y utilising the latest type catalytic conv erter and burner technology . The appliance does not requir e a flue system of any type as the catal ytic conv erter cleans the flue products to pr ovide ...

  • Smeg L23LINP - page 4

    If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue mu st be sealed off. It will be necessar y to ventilate the old flue to pre v ent condensation and dampness forming, howe v er any air v ent use d to ventilate the old flue m ust not be sited within 500mm of this appliance. I ...

  • Smeg L23LINP - page 5

    The appliance is designed to be v ersatile, and as such will operate correctly when exposed to normal gentle draughts experienced within the home. It is not r ecommended, howev er that the appliance be installed in ar eas wher e it is lik ely to be dir ectly expose d to persistent strong draughts, that ma y be generated by outside doors, windows, a ...

  • Smeg L23LINP - page 6

    Remov e the outer packaging, remo ve an y instructions or fixing kits. Read ALL these instructions before continuing to unpack or install this a ppliance. Lift off the remaining packaging components and r emov e the contents of the bo x. Check that the components supplied corr elate with the component checklist. Please dispose of all the packaging ...

  • Smeg L23LINP - page 7

    If the appliance is to be mounted on the inner leaf of a conv entional ca vity brick wall, or a solid wall, then the fibr e wall plugs and fixing scr ews pr ovided ma y be used. Depending on the condi- tion of the wall it ma y be necessary to use additional fixings. In this situation, an y additional fixings and wallplugs should be of the same size ...

  • Smeg L23LINP - page 8

    Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I ...

  • Smeg L23LINP - page 9

    Please note that the Linear and Classic models are supplied with a tinted glass facia assembly , which dif- fer in appearance when vie wed fr om the fr ont, simi- larly the F ab model is supplied with a metal facia, ho we ver the method of attachment to the appliance, for all frame designs, is the same . All models : Remov e the facia panel fr om a ...

  • Smeg L23LINP - page 10

    All models : Firstly , r emov e the decorative frame/glass facia assembly as described in section 8.3. Remove the inner glass panel, and disconnect the gas connection inside appliance. The gas connections to the gas valve can no w be released. Detach the burner front co v er plate by r emoval of the four retaining scr e ws (as shown in figur e 9, s ...

  • Smeg L23LINP - page 11

    It is recommended that the catal ysts are inspected f or signs of damage and dirt during routine servicing procedures. The expect- ed life of the catalysts is in excess of 11,000 hours (10 y ears of normal use). After this time the catalysts should be replaced . If there ar e an y deposits of dirt or soot on the catalyst they should be cleaned with ...

  • Smeg L23LINP - page 12

    Fire sparks but pilot does not light No gas to fir e, check isolators are open. Pipe work blockage, clean out. Air not fully purged, r e purge supply or wait longer . Spark earthing to metal work, reset ga p corr ectly . Block ed pilot, clean out internally . Pilot lights but then goes out Sev er e restriction in gas suppl y: clear obstruction. Fau ...

  • Smeg L23LINP - page 13

    Section Content P age No 1.0 Important Notes 1 2.0 Clearances to Combustibles 1 3.0 V entilation & Room Size 2 4.0 Operating Instructions 3 5.0 Combustion Monitoring System 3 6.0 Cleaning 3 7.0 Ser vicing 4 8.0 List of Replacement Parts 4 9.0 Installation Details 4 10.0 Ser vice Histor y 4 The installation and Ser vicing of this fir e MUST only ...

  • Smeg L23LINP - page 14

    Clearances to combustible materials Combustible materials are def ined as wood, fabrics, or other materials likel y to combust if exposed to flame. Generally , an y mate- rial, which is lik ely to discolour , melt or misshape when exposed to moderate heat, should be consider ed as a combustible mate- rial or surface. Clearance to the sides of the a ...

  • Smeg L23LINP - page 15

    Classic models : The control knob is located on the low er right hand side of the outer case.It is marked as shown in figur e 6; Linear models : The control knob is located on the low er right hand side of the outer case. It is marked as shown in figur e 7; Fab models : The contr ol knob is located on the low er right hand side of the outer case. I ...

  • Smeg L23LINP - page 16

    The appliance should be check ed on an annual basis to ensur e it is w orking safely and that ther e is no excessiv e build up of so ot. The frequency of service will depend on usage , but MUST be carried out at least once annually . Ser vicing must be carried out b y a competent person, such as a CORGI register ed installer . The Installation inst ...

Produzent Smeg Kategorie Fireplace

Dokumente, die wir vom Produzenten des Geräts Smeg L23LINP erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Smeg
- Bedienungsanleitungen L23LINP
- Produktkarten Smeg
- Informationsbroschüren
- oder Energieetiketten Smeg L23LINP
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Smeg L23LINP.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Smeg L23LINP, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Smeg L23LINP. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Smeg L23LINP ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Smeg L23LINP, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Smeg L23LINP hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Smeg L23LINP verständlich ist.

Eine gänzliche Bedienungsanleitung von Smeg sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Smeg L23LINP bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Smeg L23LINP befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Smeg L23LINP, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Smeg L23LINP - die uns die ersten Schritte während der Nutzung von Smeg L23LINP erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Smeg L23LINP hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Smeg L23LINP im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Smeg L23LINP?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Smeg L23LINP nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Smeg L23LINP hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)