Bedienungsanleitung Chicago Electric 91814

22 Seiten 0.7 mb
Download

Zur Seite of 22

Summary
  • Chicago Electric 91814 - page 1

    PLASMA AIR CUTTER 220 VOL T - 36 AMP INVER TER TECHNOLOGY ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 MISSION OAKS BL VD ., CAMARILLO , CA 93011 VISIT OUR WEB SITE A T HTTP://WWW .HARBORFREIGHT .COM Cop yright © 2004 b y Harbor F reight T ools ® . All r ights reser v ed. No por tion of this manual or any ar twork contained herein may be reproduce ...

  • Chicago Electric 91814 - page 2

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 2 Contents SPECIFICA TIONS ............................................................................ 3 GENERAL SAFETY R ULES ............................................................ 3 SPECIFIC SAFETY R ULES ....................... ...

  • Chicago Electric 91814 - page 3

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 3 SPECIFICA TIONS Cutting Depth 3/8 inch on steel Cutting Current 5 to 36 Amps listed Rated Load V oltage 100 VDC No-load V oltage 200 VDC (maximum) P ower Consumption 220 V A C, 15 Amps, 50/60 Hz, single phase Line Cord 6’ - 9” long ...

  • Chicago Electric 91814 - page 4

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 4 of flammab le liquids, gases, or dust. P ower tools create sparks which ma y ignite the dust or fumes. 3. Keep bystander s, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Protect ...

  • Chicago Electric 91814 - page 5

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 5 13. Remove adjusting keys or wrenches before turning the power tool on. A wrench or a key that is left attached to a rotating par t of the pow er tool ma y result in personal injur y . 14. Do not overreac h. Keep proper footing and bal ...

  • Chicago Electric 91814 - page 6

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 6 SPECIFIC SAFETY R ULES 1. Maintain labels and nameplates on the Air Plasma Cutter . These carr y impor tant inf or mation. If unreadab le or missing, contact Harbor F reight T ools f or a replacement. 2. Maintain a safe working en viro ...

  • Chicago Electric 91814 - page 7

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 7 not possib le, designate someone to ser v e as a fire w atch, equipped with a fire e xtin- guisher , dur ing the cutting process and for at least one half hour after the cutting is completed. • Do not cut on materials havin g a com ...

  • Chicago Electric 91814 - page 8

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 8 • Follo w OSHA guidelines for P er missible Exposure Limits (PEL ’ s) for various fumes and gases. • Fol low the American Conf erence of Gov er nmental Industrial Hygienists recommend a- tions f or Threshold Limit V alues (TL V? ...

  • Chicago Electric 91814 - page 9

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 9 GR OUNDING This Air Plasma Cutter requires a 3-prong, 220 V A C, polarized, twistlock plug (not sup- plied). This plug must be installed by a qualified electrician. W ARNING! Improperl y connecting the grounding wire can result in the ...

  • Chicago Electric 91814 - page 10

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 10 SYMBOLOGY T able B UNP A CKING When unpacking, check to make sure that all the par ts are included. Refer to the Assembly section, and the Assembly Diag rams and P ar ts List on pages 15 & 16. If any par ts are missing or broken, ...

  • Chicago Electric 91814 - page 11

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 11 ASSEMBL Y INSTR UCTIONS 1. Connect a 3-prong, 220 V A C , polarized, twistlock plug (not supplied) to the Line Cord. This plug must be installed b y a qualified electrician. 2. Attach the Pressure Gauge to the Air Regulator (58). The ...

  • Chicago Electric 91814 - page 12

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 12 OPERA TING INSTRUCTIONS SETUP Before beginning, please read and understand the section “Specific Safety Rules” starting on page 6. 1. Mount the metal to be cut to a metal welding-cutting table (not supplied). It should be mounted ...

  • Chicago Electric 91814 - page 13

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 13 DURA TION OF USE (DUTY CYCLE) A void damage to the Cutter b y not leaving it on for more than the prescribed duration of use . The Duration of Use (or Duty Cycle) defines the number of minutes , within a 10 minute per iod, dur ing wh ...

  • Chicago Electric 91814 - page 14

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 14 PR OPER CUTTING TECHNIQUE 14. T o cut efficiently , the follo wing steps must be carefully f ollowed: √ Lightly touc h the Tip to the cutting surface . √ CONT A CT WITH THE WORK SURF A CE MUST BE MAINT AINED OR THE UNIT WIL ...

  • Chicago Electric 91814 - page 15

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 15 INSPECTION, MAINTENANCE, AND CLEANING W ARNING! Make sure the P ower Switc h of the Plasma Cutter is in its “OFF” position and that the tool is unplug ged fr om the electrical outlet before performing any inspec- tion, maintenance ...

  • Chicago Electric 91814 - page 16

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 16 CIRCUIT DIA GRAM PLEASE READ THE FOLLO WING CAREFULL Y THE MANUF A CTURER AND/O R DISTRIBU T OR HAS PRO VIDED THE P AR TS DIA GRAM IN THIS MANU AL AS A REFE RENC E T OOL ONL Y . NEIT HER THE MAN UF A CTUR ER NOR DIST RIB UT OR MAKES A ...

  • Chicago Electric 91814 - page 17

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 17 NO TE : Some par ts are listed and shown for illustration pur poses only and are not av ailable individually as replacement par ts. P AR TS LIST 59 Part Description Qty 1 Housing 1 2 End Cov er , Plastic 2 3 Current Adjusting Knob 1 4 ...

  • Chicago Electric 91814 - page 18

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 18 NO T SHO WN #54 Grounding Clamp/Cable #58 Air Regulator w/gauge ASSEMBL Y DIA GRAM REV 07/05; 06/06 ...

  • Chicago Electric 91814 - page 19

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 20

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 21

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 22

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

Produzent Chicago Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Chicago Electric 91814 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Chicago Electric
- Bedienungsanleitungen 91814
- Produktkarten Chicago Electric
- Informationsbroschüren
- oder Energieetiketten Chicago Electric 91814
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Chicago Electric 91814.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Chicago Electric 91814, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Chicago Electric 91814. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Chicago Electric 91814 ansehen.

Die komplette Bedienungsanleitung des Geräts Chicago Electric 91814, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Chicago Electric 91814 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Chicago Electric 91814 verständlich ist.

Eine gänzliche Bedienungsanleitung von Chicago Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Chicago Electric 91814 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Chicago Electric 91814 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Chicago Electric 91814, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Chicago Electric 91814 - die uns die ersten Schritte während der Nutzung von Chicago Electric 91814 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Chicago Electric 91814 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Chicago Electric 91814 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Chicago Electric 91814?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Chicago Electric 91814 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Chicago Electric 91814 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)