    PLASMA AIR CUTTER 220 VOL T - 36 AMP INVER TER TECHNOLOGY ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 MISSION OAKS BL VD ., CAMARILLO , CA 93011 VISIT OUR WEB SITE A T HTTP://WWW .HARBORFREIGHT .COM Cop yright © 2004 b y Harbor F reight T ools ® . All r ights reser v ed. No por tion of this manual or any ar twork contained herein may be reproduce ...

  • Chicago Electric 91814 - page 2

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 2 Contents SPECIFICA TIONS ............................................................................ 3 GENERAL SAFETY R ULES ............................................................ 3 SPECIFIC SAFETY R ULES ....................... ...

  • Chicago Electric 91814 - page 3

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 3 SPECIFICA TIONS Cutting Depth 3/8 inch on steel Cutting Current 5 to 36 Amps listed Rated Load V oltage 100 VDC No-load V oltage 200 VDC (maximum) P ower Consumption 220 V A C, 15 Amps, 50/60 Hz, single phase Line Cord 6’ - 9” long ...

  • Chicago Electric 91814 - page 4

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 4 of flammab le liquids, gases, or dust. P ower tools create sparks which ma y ignite the dust or fumes. 3. Keep bystander s, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Protect ...

  • Chicago Electric 91814 - page 5

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 5 13. Remove adjusting keys or wrenches before turning the power tool on. A wrench or a key that is left attached to a rotating par t of the pow er tool ma y result in personal injur y . 14. Do not overreac h. Keep proper footing and bal ...

  • Chicago Electric 91814 - page 6

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 6 SPECIFIC SAFETY R ULES 1. Maintain labels and nameplates on the Air Plasma Cutter . These carr y impor tant inf or mation. If unreadab le or missing, contact Harbor F reight T ools f or a replacement. 2. Maintain a safe working en viro ...

  • Chicago Electric 91814 - page 7

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 7 not possib le, designate someone to ser v e as a fire w atch, equipped with a fire e xtin- guisher , dur ing the cutting process and for at least one half hour after the cutting is completed. • Do not cut on materials havin g a com ...

  • Chicago Electric 91814 - page 8

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 8 • Follo w OSHA guidelines for P er missible Exposure Limits (PEL ’ s) for various fumes and gases. • Fol low the American Conf erence of Gov er nmental Industrial Hygienists recommend a- tions f or Threshold Limit V alues (TL V? ...

  • Chicago Electric 91814 - page 9

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 9 GR OUNDING This Air Plasma Cutter requires a 3-prong, 220 V A C, polarized, twistlock plug (not sup- plied). This plug must be installed by a qualified electrician. W ARNING! Improperl y connecting the grounding wire can result in the ...

  • Chicago Electric 91814 - page 10

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 10 SYMBOLOGY T able B UNP A CKING When unpacking, check to make sure that all the par ts are included. Refer to the Assembly section, and the Assembly Diag rams and P ar ts List on pages 15 & 16. If any par ts are missing or broken, ...

  • Chicago Electric 91814 - page 11

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 11 ASSEMBL Y INSTR UCTIONS 1. Connect a 3-prong, 220 V A C , polarized, twistlock plug (not supplied) to the Line Cord. This plug must be installed b y a qualified electrician. 2. Attach the Pressure Gauge to the Air Regulator (58). The ...

  • Chicago Electric 91814 - page 12

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 12 OPERA TING INSTRUCTIONS SETUP Before beginning, please read and understand the section “Specific Safety Rules” starting on page 6. 1. Mount the metal to be cut to a metal welding-cutting table (not supplied). It should be mounted ...

  • Chicago Electric 91814 - page 13

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 13 DURA TION OF USE (DUTY CYCLE) A void damage to the Cutter b y not leaving it on for more than the prescribed duration of use . The Duration of Use (or Duty Cycle) defines the number of minutes , within a 10 minute per iod, dur ing wh ...

  • Chicago Electric 91814 - page 14

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 14 PR OPER CUTTING TECHNIQUE 14. T o cut efficiently , the follo wing steps must be carefully f ollowed: √ Lightly touc h the Tip to the cutting surface . √ CONT A CT WITH THE WORK SURF A CE MUST BE MAINT AINED OR THE UNIT WIL ...

  • Chicago Electric 91814 - page 15

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 15 INSPECTION, MAINTENANCE, AND CLEANING W ARNING! Make sure the P ower Switc h of the Plasma Cutter is in its “OFF” position and that the tool is unplug ged fr om the electrical outlet before performing any inspec- tion, maintenance ...

  • Chicago Electric 91814 - page 16

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 16 CIRCUIT DIA GRAM PLEASE READ THE FOLLO WING CAREFULL Y THE MANUF A CTURER AND/O R DISTRIBU T OR HAS PRO VIDED THE P AR TS DIA GRAM IN THIS MANU AL AS A REFE RENC E T OOL ONL Y . NEIT HER THE MAN UF A CTUR ER NOR DIST RIB UT OR MAKES A ...

  • Chicago Electric 91814 - page 17

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 17 NO TE : Some par ts are listed and shown for illustration pur poses only and are not av ailable individually as replacement par ts. P AR TS LIST 59 Part Description Qty 1 Housing 1 2 End Cov er , Plastic 2 3 Current Adjusting Knob 1 4 ...

  • Chicago Electric 91814 - page 18

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 18 NO T SHO WN #54 Grounding Clamp/Cable #58 Air Regulator w/gauge ASSEMBL Y DIA GRAM REV 07/05; 06/06 ...

  • Chicago Electric 91814 - page 19

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 20

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 21

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 22

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

Производитель Chicago Electric Категория Welder

Документы, которые мы получаем от производителя устройства Chicago Electric 91814 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Chicago Electric
- инструкции обслуживания 91814
- паспорта изделия Chicago Electric
- информационные брошюры
- энергетические этикетки Chicago Electric 91814
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Chicago Electric 91814.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Chicago Electric 91814, инструкции обслуживания, короткие инструкции или инструкции пользователя Chicago Electric 91814. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Chicago Electric 91814.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Chicago Electric 91814, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Chicago Electric 91814 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Chicago Electric 91814.

Полная инструкция обслуживания Chicago Electric, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Chicago Electric 91814 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Chicago Electric 91814, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Chicago Electric 91814, которое найдем в данном документе
3. Советы по использованию основных функций устройства Chicago Electric 91814 - которые должны облегчить нам первые шаги во время использования Chicago Electric 91814
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Chicago Electric 91814
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Chicago Electric 91814 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Chicago Electric 91814?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Chicago Electric 91814, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Chicago Electric 91814 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)